Search results for " Ultraviolet"
showing 10 items of 337 documents
Biogenic synthesis of palladium nanoparticles using Pulicaria glutinosa extract and their catalytic activity towards the Suzuki coupling reaction.
2014
Green synthesis of nanomaterials finds the edge over chemical methods due to its environmental compatibility. Herein, we report a facile and eco-friendly method for the synthesis of palladium (Pd) nanoparticles (NPs) using an aqueous solution of Pulicaria glutinosa, a plant widely found in a large region of Saudi Arabia, as a bioreductant. The as-prepared Pd NPs were characterized using ultraviolet-visible (UV-vis) spectroscopy, powder X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), and Fourier transform-infrared spectroscopy (FT-IR). The hydroxyl groups of the plant extract (PE) molecules were found mainly responsible for the red…
Spectrophotometric determination of adrenaline with an oxidative column in a FIA assembly
1990
Abstract A single channel FIA assembly is proposed for the spectrophotometric determination of adrenaline, the aqueous sample solution is directly injected into the carrier stream leading the sample through a manganese dioxide column at 80°C, and on to the spectrophotometer flow-cell. The calibration graph is linear up to 17 ppm of adrenaline. The influence of other substances has been studied and the method has been applied to the determination of adrenaline in a pharmaceutical formulation.
A new ionic liquid dimethyldinonylammonium bromide as a flow modifier for the simultaneous determination of eight carboxylates by capillary electroph…
2005
Two new methods of capillary zone electrophoresis based on aqueous phosphate running buffers with UV spectrophotometric detection were developed and optimized for the determination of eight carboxylates as copper complexes. Metalcomplexes are negatively charged, so measurements were made as anion analyses with flow reversal in the capillary. Two flow modifiers were used: a common tetradecyltrimethylammonium bromide (TTAB) and a new ionic liquid dimethyldinonylammonium bromide (DMDNAB). The methods were compared to each other. Better separation was achieved with DMDNAB as the flow modifier. Method development was done using a fused silica capillary (61 cm x 50 microm i.d.). Optimization was …
Simple high-performance liquid chromatographic assay for polyamines and their monoacetyl derivatives.
1993
A rapid reversed-phase high-performance liquid chromatographic method, using pre-column derivatization with benzoyl chloride and ultraviolet detection at 254 nm, was developed for the simultaneous measurement of polyamines and their monoacetyl derivatives. Calibration curves were linear for concentrations from 1.25 to 25 nmol/ml. The method was employed to assay these compounds in chick embryo retina explants using organic solvent extraction and 1,7-diaminoheptane as an internal standard. This simple and sensitive method can be applied to routine determinations of these compounds in various biological samples.
Evaluation by HPLC-UV of Polar Pesticides in Rice Fields
1999
Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…
2002
A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…
Improvement of peak shape and separation performance of beta-blockers in conventional reversed-phase columns using solvent modifiers.
2003
A comparative study of peak shape, elution behavior, and resolution of 16 beta-blockers (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol, and timolol) chromatographed with hybrid mobile phases of triethylamine (TEA)-acetonitrile and sodium dodecyl sulfate (SDS)-propanol is performed using conventional reversed-phase columns and isocratic elution. Both solvent modifiers (TEA and SDS) prevent the interaction of the basic drugs with the alkyl-bonded phase. However, the protection mechanisms of silanols on the packing are different. Whereas TEA associates with the silanol sites (b…
High-performance liquid chromatographic determination of Maillard compounds in store-brand and name-brand ultra-high-temperature-treated cows' milk.
2000
Furosine and furfural products of the Maillard reaction are used as specific indicators of the effect of heating treatments on milk quality. Their contents were measured in representative samples of store- and name-brand ultra-high-temperature-treated milks using RP-HPLC with UV detection. Furosine contents ranged from 40.32 to 50.67 and from 65.48 to 310.58 mg/100 g protein in name- and store-brand milks, respectively. Of the furfurals, only hydroxymethylfurfural was detected. The free hydroxymethylfurfural contents of store-brand milks ranged from 0.22 to 1.70 mg/100 g protein. Total hydroxymethylfurfural contents ranged from 0.29 to 0.41 and from 0.72 to 2.21 mg/100 g protein, for name- …
Reliability of the retention factor estimations in liquid chromatography.
2004
The retention factor is one of the most universally used parameters in chromatography. However, large differences in the experimental retention factor values are observed when the same compound is injected in a given stationary/mobile phase system under intermediate precision conditions. Conventional protocols for estimating retention factors have problems that mainly arise from difficulties in the hold-up time measurements and the omission of the existence of extra-column times by practicing chromatographers. In the present paper, three different approaches for estimating retention factors are tested: (i) classical retention factor estimations based on the gross hold-up time, (ii) based on…
Critical study of and improvements in chromatographic methods for the analysis of type B trichothecenes
2001
Various analytical methods used in the analysis of type B trichothecenes (deoxynivalenol, nivalenol, 3- and 15-acetyldeoxynivalenol) in cereals were compared and optimised in this work. These methods use either GC-electron-capture detection (ECD) of trimethylsilyl, trifluoroacetyl and heptafluorobutyryl derivatives or HPLC with UV or photodiode array detection of analytes. A new HPLC procedure using fluorescence detection prior derivatisation with coumarin-3-carbonyl chloride has been also tested. Five extraction solvents and two solid-phase extraction cartridges (silica, Florisil) plus a especial clean-up column (MycoSep 225) were compared in order to obtain the best recovery of the mycoto…