Search results for " agreement"

showing 10 items of 188 documents

A new set of 299 pictures for psycholinguistic studies : French norms for name agreement, image agreement, conceptual familiarity, visual complexity,…

2003

Pictures are often used as stimuli in studies of perception, language, and memory. Since performances on different sets of pictures are generally contrasted, stimulus selection requires the use of standardized material to match pictures across different variables. Unfortunately, the number of standardized pictures available for empirical research is rather limited. The aim of the present study is to provide French normative data for a new set of 299 black-and-white drawings. Alario and Ferrand (1999) were closely followed in that the pictures were standardized on six variables: name agreement, image agreement, conceptual familiarity, visual complexity, image variability, and age of acquisit…

AdultMaleAdolescentComputer sciencemedia_common.quotation_subjectExperimental and Cognitive Psychologycomputer.software_genreLanguage Development050105 experimental psychologyVisual complexity03 medical and health sciences0302 clinical medicineEmpirical researchPerceptionHumans0501 psychology and cognitive sciencesGeneral PsychologyLanguagemedia_commonName agreementPsycholinguisticsPsychology Experimentalbusiness.industry05 social sciencesAge of AcquisitionPictorial stimuli[SCCO.PSYC]Cognitive science/Psychology[SCCO.PSYC] Cognitive science/PsychologyVisual PerceptionNormativeFemalePsychology (miscellaneous)Artificial intelligenceFactor Analysis Statisticalbusinesscomputer030217 neurology & neurosurgeryNatural language processing
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

2009

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …

AdultMaleFluid responsivenessBlood PressureAutomationMonitoring IntraoperativeAbdomenMedicineHumansIn patientPulseAgedObserver VariationBlood Volumebusiness.industryAirway ResistanceLimits of agreementReproducibility of ResultsMiddle AgedReference StandardsPulse pressureAnesthesiology and Pain MedicineBlood pressureData Interpretation StatisticalRespiratory MechanicsFemalebusinessAlgorithmAlgorithmsAnesthesia and analgesia
researchProduct

Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist

2019

Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…

AdultMalegyroscopeInertial frame of referenceCorrelation coefficientAdolescentMovementPhysical Therapy Sports Therapy and Rehabilitation030204 cardiovascular system & hematologyAccelerometerwearablelaw.invention03 medical and health sciencesWearable Electronic DevicesYoung Adult0302 clinical medicineInertial measurement unitlawAccelerometryHumansOrthopedics and Sports MedicineliikeanalyysiChildsignal processingSimulationMathematicsAgedinertial measurement unitLimits of agreementGyroscope030229 sport sciencesMiddle AgedBiomechanical PhenomenamittausmenetelmätaccelerometerArm swingJumpExercise TestFemalehyppääminenperformance
researchProduct

Ventilatory threshold during incremental running can be estimated using EMG shorts

2012

The present study examined whether shorts with textile electromyographic (EMG) electrodes can be used to detect second ventilatory threshold (V(T2)) during incremental treadmill running. Thirteen recreationally active (REC) and eight endurance athletes were measured for EMG, heart rate, blood lactate and respiratory gases during VO(2max) test (3 min ramps, 1 km·h(-1) increments). V(T)(2), onset of blood lactate accumulation (OBLA) and EMG threshold (EMG(T)) were determined. In athletes, OBLA occurred at 56 ± 6 mL·kg(-1)·min(-1), V(T2) occurred at 59 ± 6 mL·kg(-1)·min(-1), and EMG(T) at 62 ± 6 mL·kg(-1)·min(-1) without significant differences between methods (analysis of variance: ANOVA). In…

AdultMalemedicine.medical_specialtyAnaerobic ThresholdPhysiologyLactic acid bloodBiomedical EngineeringBiophysicsRunningTreadmill runningPhysiology (medical)Internal medicineHeart rateBlood lactateHumansMedicineLactic AcidElectromyographybusiness.industryLimits of agreementAthletesPhysical EnduranceCardiologyPhysical therapyPulmonary VentilationVentilatory thresholdbusinessPhysiological Measurement
researchProduct

Non‐invasive haemoglobin measurement as an index test to detect pre‐operative anaemia in elective surgery patients – a prospective study

2020

Non-invasive haemoglobin measurement using absolute values lacks the precision to be the sole basis for the treatment of pre-operative anaemia. However, it can possibly serve as a screening test, indexing 'anaemia' with high sensitivity when values remain under prespecified cut-off values. Based on previous data, non-invasive haemoglobin cut-off values (146 g.l-1 for women and 152 g.l-1 for men) detect true anaemia with 99% sensitivity. An index test with these prespecified cut-off values was verified by prospective measurement of non-invasive and invasive haemoglobin pre-operatively in elective surgical patients. In 809 patients, this showed an estimated sensitivity (95%CI) of 98.9% (94.1-…

AdultMalemedicine.medical_specialtyHaemoglobin levelsSensitivity and SpecificityHemoglobins03 medical and health sciences0302 clinical medicine030202 anesthesiologyInternal medicinePreoperative CareHumansMedicineProspective Studies030212 general & internal medicineElective surgeryProspective cohort studyAgedHematologic Testsbusiness.industryNon invasiveLimits of agreementIndex testAnemiaMiddle AgedPre operativeAnesthesiology and Pain MedicineElective Surgical ProceduresFemalebusinessSurgical patientsAnaesthesia
researchProduct

Assessment of Kinect V2 for elbow range of motion estimation in people with haemophilia using an angle correction model

2018

Introduction The joint range of motion (ROM) is an important clinical parameter used to assess the loss of functionality resulting from joint bleedings in people with haemophilia. These episodes require a close follow-up and, to decrease patients' hospital dependence, telemedicine tools are needed. Therefore, this study is aimed to analyse the validity of the Microsoft Kinect V2 sensor with corrected angle measurement to be used in the monitoring of elbow ROM in people with haemophilia. Methods A convenience sample of 10 healthy controls (CG) and 10 patients with haemophilia with elbow arthropathy (HG) participated in this study. Full ROM of elbow joints was measured in the frontal view wit…

AdultMalemedicine.medical_specialtyWilcoxon signed-rank testElbow030204 cardiovascular system & hematologyHemophilia AHaemophiliarange of motion03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationElbow JointHemarthrosisArthropathymedicineElbow jointsupper extremityHumansRange of Motion ArticularGenetics (clinical)Models Statisticalbusiness.industryLimits of agreementhaemophilic arthropathy3D depth sensorHematologyGeneral Medicinemedicine.diseasemedicine.anatomical_structureGoniometerFemaleRange of motionbusinessgoniometry030215 immunology
researchProduct

El proyecto mapa escolar de Valencia: Análisis de la zonificación educativa de la ciudad de Valencia

2018

The research project Mapa Escolar de Valencia (School Map of Valencia) was born out of an agreement between the City Council and the University of Valencia in order to carry out an investigation of the compulsory education system of the city and propose, if necessary, modifications to the current school zoning. The project is structured in several research areas. An analysis of the specialized scientific literature and public policies concerning education and schooling has been done, and it is currently analysing the evolution of quantitative and qualitative data on compulsory schooling in Valencia, its school zoning, the representations of education and the school climate in the city schoo…

Análisis de la zonificación educativa de la ciudad de Valencia de Madaria Escudero [1137-7038 8537 Arxius de sociologia 514142 2018 39 6874491 El proyecto mapa escolar de Valencia]zonificación escolardezoningMuñoz Rodríguezits school zoningVila LladosaValencia 129 142the representations of education and the school climate in the city schools. The main results of the research are presented in this article Mapa escolarschool zoningUNESCO::SOCIOLOGÍAmodifications to the current school zoning. The project is structured in several research areas. An analysis of the specialized scientific literature and public policies concerning education and schooling has been doneGabaldón Estevanschool social segregation1137-7038 8537 Arxius de sociologia 514142 2018 39 6874491 El proyecto mapa escolar de Valencia: Análisis de la zonificación educativa de la ciudad de Valencia de Madaria EscuderoRequena i MoraSchoolingRodríguez VictorianoSandraJosé Manuel The research project Mapa Escolar de Valencia (School Map of Valencia) was born out of an agreement between the City Council and the University of Valencia in order to carry out an investigation of the compulsory education system of the city and proposeDanielsegregación escolareducation equityLuisescolarización:SOCIOLOGÍA [UNESCO]García De FezMarinaDavidequidad educativaif necessarydistrito únicoBorjaValenciaand it is currently analysing the evolution of quantitative and qualitative data on compulsory schooling in Valencia
researchProduct

Facility management, outsourcing and contracting overview

2009

The discipline of facility management has basically originated from the experience of the field and most of the business models are driven from the American market. The majority of surveys agree that organizational objectives vary according to different business environments. The link between a given company and its facility management department has been studied in details with a widespread agreement on the importance of tailoring to the specific context the facility management organizational model and the approach to the relationships with suppliers. In Europe two Technical Committees of the Comite Europeen de Normalisation (CEN) are currently adding to the body of knowledge terminologies…

Body of knowledgeService-level agreementFacility managementProcess managementStandardizationbusiness.industryDMAICBusiness modelbusinessImplementationOutsourcing
researchProduct

Algunas reflexiones acerca de la stjue de 9 de julio de 2020 sobre los pactos novatorios en materia de cláusulas suelo

2021

The Sentence of the Court of Justice of the European Union of July 9, 2020 comes to answer the five questions that, in its preliminary question, the Court of First Instance and Instruction No. 3 of Teruel asks about the validity of the new agreements in the context of the floor clauses, establishing jurisprudential doctrine on this matter about which our Supreme Court had previously ruled in its Judgments of October 16, 2017, in the sense of considering the agreed floor clause null as a consequence of the novation agreement and, subsequently, those of April 11, 2018 and September 13, 2018 in the opposite direction, declaring that the novation agreement was valid. It is a long-awaited and in…

Carolina del Carmen The Sentence of the Court of Justice of the European Union of July 9and its economic repercussion - as well as its procedural significance. -by the consequence of the lifting of procedural suspensions that its dictation supposes2018 in the opposite direction2017consumidorin its preliminary question2018 and September 13cláusula suelothe Court of First Instance and Instruction No. 3 of Teruel asks about the validity of the new agreements in the context of the floor clausesno doubtpacto novatorioagreed as a result of the ruling of the Luxembourg Court-. In this paper I will review the doctrine contained in the STJUE in its comparison with the one previously declared by our Supreme Courtremunerative interestMortgage:CIENCIAS JURÍDICAS [UNESCO]in attentioninterest variability 132 159consumerestablishing jurisprudential doctrine on this matter about which our Supreme Court had previously ruled in its Judgments of October 16new agreementsubsequentlyboth to its well-founded substantive relevance - due to the legal doctrine that it consolidates and which results from unquestionable applicationvariabilidad del interés.2070-8157 22082 Revista Boliviana de Derecho 565487 2021 31 7730055 Algunas reflexiones acerca de la stjue de 9 de julio de 2020 sobre los pactos novatorios en materia de cláusulas suelo Castillo Martínezdeclaring that the novation agreement was valid. It is a long-awaited and insistently commented resolution after its publication2020 comes to answer the five questions thatthose of April 11in the sense of considering the agreed floor clause null as a consequence of the novation agreement andin order to conclude what its incidence is with respect to the criterion maintained by our High Court in its Judgments of April 11UNESCO::CIENCIAS JURÍDICASfloor clauseinterés remuneratorio2018. Hipoteca
researchProduct