Search results for " aortic"

showing 10 items of 302 documents

Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation p…

2016

Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into thr…

OversizingTranscatheter aortic valve implantationAortic regurgitation; Aortic valve stenosis; Multislice-CT; Oversizing; Transcatheter aortic valve implantationSymposium: Transcatheter aortic valve implantationAortic valve stenosiAortic regurgitationAortic valve stenosisMultislice-CT
researchProduct

Novel contributions of neutrophils in the pathogenesis of abdominal aortic aneurysm, the role of neutrophil extracellular traps: A systematic review.

2020

Abdominal aortic aneurysm (AAA) is a vascular disorder caused by a dilatation of the aortic diameter that can be potentially lethal in case of rupture. Molecular mechanisms underlying the development of AAA are complex and not completely understood. However, inflammation plays a pivotal role in AAA development. Infiltration of inflammatory cells, especially macrophages, has been widely observed in lesion areas. Nevertheless, neutrophils have been gaining importance in the context of AAA. The release of neutrophil extracellular traps (NETs), extracellular structures formed by DNA, histones, granular and cytoplasmic proteins, is a recently discovered mechanism of neutrophil activation that ca…

Pathologymedicine.medical_specialtyNeutrophilsInflammationmacromolecular substances030204 cardiovascular system & hematologyExtracellular TrapsNeutrophil ActivationLesionPathogenesis03 medical and health sciences0302 clinical medicinemedicineExtracellularHumanscardiovascular diseasesbusiness.industryThrombosisHematologyNeutrophil extracellular trapsmedicine.diseaseAbdominal aortic aneurysm030220 oncology & carcinogenesisVascular Disordercardiovascular systemmedicine.symptombusinessInfiltration (medical)Aortic Aneurysm AbdominalThrombosis research
researchProduct

Ferroelectricity and piezoelectricity in soft biological tissue: Porcine aortic walls revisited

2017

Recently reported piezoresponse force microscopy (PFM) measurements have proposed that porcine aortic walls are ferroelectric. This finding may have great implications for understanding biophysical properties of cardiovascular diseases such as arteriosclerosis. However, the complex anatomical structure of the aortic wall with different extracellular matrices appears unlikely to be ferroelectric. The reason is that a prerequisite for ferroelectricity, which is the spontaneous switching of the polarization, is a polar crystal structure of the material. Although the PFM measurements were performed locally, the phase-voltage hysteresis loops could be reproduced at different positions on the tis…

PermittivityMaterials sciencePhysics and Astronomy (miscellaneous)FerroelectricityPiezoresponse force microscopyPiezoelectricityHOL - HolstNanotechnology02 engineering and technologyDielectricPFM01 natural sciences0103 physical sciences010306 general physicsTS - Technical SciencesIndustrial InnovationElectrostrictionCondensed matter physics021001 nanoscience & nanotechnologyPiezoelectricityFerroelectricityHysteresisPorcine aortic wallsPiezoresponse force microscopyNano Technology0210 nano-technologyElectric displacement fieldBiological tissue
researchProduct

Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair

2019

Summary: Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath…

Pigtailmedicine.medical_specialtyPercutaneouscannulation610 Medicine & healthSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationRetrospective Studiemedicine.arterygatemedicineStentFluoroscopyHumansEVARREVARRenal arteryRetrospective StudiesAortamedicine.diagnostic_testbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Proceduresmedicine.diseaseAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisCatheterBlood Vessel ProsthesiTreatment Outcomecontralateral limbIntroducer sheathStentsCardiology and Cardiovascular MedicinebusinessHumanAortic Aneurysm Abdominal
researchProduct

Relationship between plasma endothelin-1 and aortic stiffness in hypertensive patients with chronic kidney disease

2012

Plasma endothelin aortic stiffnes chronic kidney disease arterial hypertension
researchProduct

Penetrating aortic ulcer post migration of thoracic aortic endoprosthesis: Case report

2021

Introduction Thoracic endovascular aortic repair (TEVAR) is the first treatment option for many thoracic aortic pathologies. Especially after aortic dissections, it is possible to have progression during follow-up with appearance of new lesions on arterial wall. Herein, we report a case of Penetrating Aortic Ulcer (PAU) post release of Thoracic endoprosthesis. Presentation of case A 67-years-old male with hypertension and diabetes mellitus was followed at our hospital after an emergency procedure for Type B aortic dissection (TBAD) complicated by symptomatic large infrarenal AAA and treated with a proximal TEVAR plus chimney for left subclavian artery and PETTICOAT with EVAR for abdominal a…

Post releasemedicine.medical_specialtyTEVARbusiness.industrymedicine.medical_treatmentStentTreatment optionsmedicine.diseaseAortic diseaseProsthesisSettore MED/22 - Chirurgia VascolareSurgeryPenetrating atherosclerotic ulcerPenetrating atherosclerotic ulcermedicine.arteryCase reportcardiovascular systemmedicineThoracic aortaSurgeryArterial wallComplicated aortic B dissectionbusinessMigration endoprosthesis
researchProduct

Pēcimplantācijas sindroms pacientiem ar abdominālās aortas aneirismu pēc endovaskulāras aneirismas ārstēšanas

2020

Ievads: Endovaskulāra aneirismas ārstēšana (EVAR - Endovascular Aneurysm Repair) ir rutīnā izmantota metode abdominālās aortas aneirismas (AAA) ārstēšanā. Pēcimplantācijas sindroms (PIS) ir labdabīga sistēmiska iekaisuma atbilde, ko novēro pēc EVAR un kas bioķīmiski un klīniski izpaužas ar iekaisumu bez infekcijas. Laboratoriskajiem rādītājiem ir loma PIS diagnostikā. Būtiski ir to diferencēt no infekcijas. Šobrīd asinsvadu ķirurgu vidū nav vienprātības par to, kā definēt PIS - febrils drudzis ir nemainīga paradigma, tomēr leikocitozes robežvērtības definīcijās atšķiras, tādējādi ietekmējot incidenci. Ir zināms, ka febriliem pacientiem ar leikocitozi agrīnā pēcoperācijas periodā izteikti do…

Post-Implantation SyndromePISEVARAAAAbdominal Aortic AneurysmMedicīna
researchProduct

Computational fluid dynamics of the ascending aorta before the onset of type A aortic dissection.

2016

We performed a pre-dissection computational fluid analysis of an ascending aortic aneurysm associated with unicuspid aortic valve. The analysis showed an abnormal helical flow pattern inside the aneurysm and an increased wall stress on the right postero-lateral wall of the ascending aorta. These values were largely higher than the theoretical cut-off for aortic wall dissection, their topographic distribution followed the intimal tear site as subsequently diagnosed by computed tomography scan and confirmed during the operation for dissection repair.

Pulmonary and Respiratory MedicineAdultMalemedicine.medical_specialty0206 medical engineeringBlood Pressure02 engineering and technologyDissection (medical)030204 cardiovascular system & hematologyAortographyComputer03 medical and health sciencesAortic aneurysm0302 clinical medicineAneurysmAneurysm Dissectingmedicine.arteryInternal medicineAscending aortamedicineHumansComputer SimulationAortaAortic dissectionAortabusiness.industryModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeHydrodynamicGeneral Medicinemedicine.disease020601 biomedical engineeringUnicuspid aortic valveAortic wallAortic AneurysmAortic Dissectioncardiovascular systemCardiologyHydrodynamicsSurgeryStress MechanicalCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedBlood Flow VelocityHumanEuropean journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
researchProduct

Mid-term results of bicuspid aortic valve repair guided by morphology and function assessment.

2016

Bicuspid aortic valve (BAV) is frequently associated with aortic insufficiency (AI) due to cusp disease and/or aortic root dilatation. Based on functional classification and morphology, a systematic surgical approach was used for aortic valve repair (AVr).From 2004 to 2014, 152 consecutive patients (mean age 55 ± 7 years) with BAV underwent AVr with or without concomitant aortic root surgery. Cusp pathology was treated with central plication in 60 (39.5%) patients, free edge reinforcement in 45 (29.6%), triangular resection in 28 (18.4%) and pericardial patch in 19 (12.5%). Aortic root dilatation was corrected with valve sparing reimplantation in 65 patients. Mean follow-up was 68 ± 36 mont…

Pulmonary and Respiratory MedicineAortic valveMalemedicine.medical_specialtyTime FactorsHeart VentriclesMid term resultsHeart Valve DiseasesAortic root dilatation030204 cardiovascular system & hematologyPreoperative careVentricular Function Left03 medical and health sciences0302 clinical medicineAortic valve repairBicuspid aortic valvePostoperative ComplicationsBicuspid Aortic Valve DiseaseRecurrenceInternal medicineMedicineHumansHospital MortalityRetrospective StudiesPericardial patchbusiness.industryIncidenceMiddle Agedmedicine.diseaseSurvival Ratemedicine.anatomical_structureTreatment Outcome030228 respiratory systemItalyEchocardiographyConcomitantAortic Valvecardiovascular systemCardiologySurgeryFemaleCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesInteractive cardiovascular and thoracic surgery
researchProduct

Biomechanical properties and histomorphometric features of aortic tissue in patients with or without bicuspid aortic valve

2020

Background We sought to investigate and compare biomechanical properties and histomorphometric findings of thoracic ascending aorta aneurysm (TAA) tissue from patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) in order to clarify mechanisms underlying differences in the clinical course. Methods Circumferential sections of TAA tissue in patients with BAV (BAV-TAA) and TAV (TAV-TAA) were obtained during surgery and used for biomechanical tests and histomorphometrical analysis. Results In BAV-TAA, we observed biomechanical higher peak stress and lower Young modulus values compared with TAV-TAA wall. The right lateral longitudinal region seemed to be the most fragile zon…

Pulmonary and Respiratory MedicineAortic valveTunica mediamedicine.medical_specialtyaortopathyDissection (medical)030204 cardiovascular system & hematologycomplex mixtures030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineBicuspid aortic valvefluid dynamic analysisInternal medicineparasitic diseasesmedicineIn patientAortic dissectionbiologybusiness.industryaortic wallelastic tissue fragmentationmedicine.diseasedigestive system diseasesAortic wallSettore MED/23medicine.anatomical_structureBicuspid aortic valve (BAV)biology.proteinCardiologycardiovascular systemOriginal ArticlebusinessElastin
researchProduct