Search results for " aortic"

showing 10 items of 302 documents

The rxr agonist bexarotene in combination with rosuvastatin inhibits angiotensin-ii induced abdominal aortic aneurysm formation in apoliprotein -e-kn…

2014

AgonistBexarotenemedicine.medical_specialtybusiness.industrymedicine.drug_classPharmacologyRetinoid X receptormedicine.diseaseAngiotensin IIAbdominal aortic aneurysmEndocrinologyInternal medicineKnockout mouseMedicineRosuvastatinCardiology and Cardiovascular Medicinebusinessmedicine.drugAtherosclerosis
researchProduct

Aneurismi aortici addominali, indicazioni e tecniche di trattamento

2019

Nessuno

Aneurismi aortici addominali indicazioni e tecniche di trattamentoSettore MED/22 - Chirurgia Vascolare
researchProduct

Ruolo dell’angiografia TC Multistrato cardiosincronizzata nella valutazione dell’aorta ascendente dopo chirurgia conservativa della valvola aortica.

2008

Aorta valvola aorticaSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Corrigendum to Patterns of ascending aortic dilatation and predictors of surgical replacement of the aorta: A comparison of bicuspid and tricuspid ao…

2020

The authors regret that the author name of Romano and Raffa are incorrect. The corrected author's name are Romano G and Raffa GM. The authors would like to apologise for any inconvenience caused.

Aortic dilatationAortic valveAortamedicine.medical_specialtybusiness.industrySettore ING-IND/34 - Bioingegneria Industrialeaorta bicuspid aortic valvemedicine.anatomical_structuremedicine.arteryInternal medicinemedicineCardiologyCardiology and Cardiovascular MedicinebusinessMolecular Biology
researchProduct

Predicting Outcome of Aortic Dissection with Patent False Lumen by Computational Flow Analysis

2014

Although Type B aortic dissection (AoD) has better in-hospital survival than Type A AoD, the short- and long term outcome for patients remains challenging, with 50–80% deaths at 5-years. Dissection-related complications include rapid aortic expansion, impending rupture, and malperfusion syndromes. We aimed to assess hemodynamic implications of patients with patent false lumen (FL) of dissected aorta. Computational fluid dynamic analyses were performed on patient-specific aortic geometries reconstructed from computed tomography scans of 25 patients with AoDs, who were admitted in our hospital from 2007 to 2013. We used the development of acute complications and chronic aneurysmal evolution a…

Aortic dissectionAortamedicine.medical_specialtyFlowbusiness.industryBiomedical EngineeringFalse LumenHemodynamicsBlood flowmedicine.diseaseType B Aortic DissectionSurgerySettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineBlood pressuremedicine.arteryInternal medicineLinear regressionmedicineCardiologyTearsCFDCardiology and Cardiovascular MedicineAdverse effectbusinessCardiovascular Engineering and Technology
researchProduct

DISSECTION PROPERTIES OF ANEURYSMAL AND NONANEURYSMAL HUMAN ASCENDING THORACIC AORTA: PRELIMINARY RESULTS

2010

Ascending thoracic aortic aneurysm (ATAA) is among the most devastating forms of cardiovascular disease, causing a significant mortality despite current medical and surgical treatments [1]. Moreover these therapies themselves are associated with great risk of mortality or morbidity, complicated by the advanced age of the typical patient, and high surgical costs. The mechanics of spontaneous aortic dissection is not fully understood. It is generally believed that aortic dissection initiates as an intimal tear in which a separation of wall layers produces the formation of a ‘false’ lumen. The dissection may propagate axially and/or circumferentially due to blood flow and pressure. Dissection …

Aortic dissectionAortamedicine.medical_specialtybusiness.industryLumen (anatomy)Blood flowThoracic aortic aneurysm dissectionmedicine.diseaseThoracic aortic aneurysmSurgeryEmbolismmedicine.arteryInternal medicinemedicineCardiologyRisk of mortalityThoracic aortabusiness
researchProduct

Association of Fiber Orientation and Dissection Properties of Ascending Thoracic Aortic Aneurysms With Aortic Valve Morphology

2011

Type A aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) is a life-threatening cardiovascular emergency with a high potential for death. Despite improved surgical techniques, the morbidity risk for emergent surgery remains 24% worldwide according to data from the International Registry of Acute Aortic Dissection [1].Copyright © 2011 by ASME

Aortic dissectionAortic valvemedicine.medical_specialtybusiness.industryFiber orientationMorbidity riskeducationSettore ING-IND/34 - Bioingegneria IndustrialeDissection (medical)medicine.diseaseThoracic aortic aneurysmSurgerymedicine.anatomical_structureInternal medicinecardiovascular systemmedicineCardiologybusinessaortic aneurysmASME 2011 Summer Bioengineering Conference, Parts A and B
researchProduct

Risk of aortic dissection in patients with ascending aorta aneurysm: a new biological, morphological, and biomechanical network behind the aortic dia…

2020

Thoracic aortic aneurysm represents a deadly condition, particularly when it evolves into rupture and dissection. Proper surgical timing is the key to positively influencing the survival of patients with this pathology. According to the most recent guidelines, ascending aorta size ≥ 55 mm and a rate of growth ≥ 0.5 cm per year are the most important factors for surgical indication. Nevertheless, a lot of evidence show that aortic ruptures and dissections might occur also in small size ascending aorta. In this review, we sought to analyze a new biological and morphological network behind the aortic diameter that need to be considered in order to identify the portion of patients with thoracic…

Aortic dissectionSettore MED/23business.industrymedicineIn patientAnatomyAscending aorta aneurysmAortic diameterCardiology and Cardiovascular Medicinemedicine.diseasebusinessAscending aorta aneurysm ascending aorta size aortic dissection genetic risk factors morphological aspects surgical indication for aortic repair
researchProduct