Search results for " device"
showing 10 items of 1082 documents
Response repetition vs. response change modulates behavioral and electrophysiological effects of distraction
2004
If stimulation occasionally contains distracting information, behavioral responses to task-relevant aspects of the stimulation are prolonged and more error prone. Additionally, event-related potentials (ERPs) acquired in an auditory distraction paradigm show that the distracting information elicits the components mismatch negativity (MMN), P3a and reorienting negativity (RON). Here, we assess to what extent sequential dependencies in the stimulation influence such indicators of distraction. Data of four experiments were reanalyzed for response repetition and response change trials separately. Behavioral performance on Deviants suggests markedly smaller distraction effects in change compared…
Lead-Related Infective Endocarditis in Latvia: A Single Centre Experience
2019
Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE …
Force in the Achilles Tendon During Walking With Ankle Foot Orthosis
2009
Background Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design Controlled laboratory study. Methods In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positi…
Multimodal Device for Real-Time Monitoring of Skin Oxygen Saturation and Microcirculation Function
2019
The present study introduces a recently developed compact hybrid device for real-time monitoring of skin oxygen saturation and temperature distribution. The prototype involves a snapshot hyperspectral camera, multi-wavelength illuminator, thermal camera, and built-in computer with custom-developed software. To validate this device in-vivo we performed upper arm vascular occlusion on eight healthy volunteers. Palm skin oxygen saturation maps were analyzed in real-time using k-means segmentation algorithm and two-layer optical diffuse model. The prototype system demonstrated a satisfying performance of skin hyperspectral measurements in the spectral range of 507&ndash
Control of intrauterine device insertion with three-dimensional ultrasound: is it the future?
1996
A comparative study was designed to determine whether three-dimensional transvaginal sonography (3D-TVS) offered advantages over two-dimensional transvaginal sonography (2D-TVS) for the identification and location of IUDs in 66 asymptomatic women. Hysteroscopy was performed in cases in which there was a discrepancy between the information obtained by both methods (n = 14). In eight cases (12.2%) the IUD was misidentified with 2D-TVS. In six cases (9.1%) it was not possible to identify the device model with 2D-TVS. In two cases (3.0%) 2D-TVS failed to identify the position of the device. In contrast, all IUDs were identified and located accurately with 3D-TVS. © 1996 John Wiley & Sons, Inc.
Effect of cost on early removal of contraceptive implants: a prospective cohort study
2019
OBJECTIVES To evaluate the effect of the cost of subdermal etonogestrel implant (SEI) on the continuation rate one year after insertion, and to assess the reasons given by users to remove the implant before the expiration date. METHODS Prospective cohort study conducted among 265 women who chose the SEI as a contraceptive method in a sexual and reproductive health center in the eastern region of Spain, between October/2012 and October/2017. The sample was divided into two cohorts depending on the cost of the implant for the user (free-of-charge or requiring partial payment). Kaplan-Meier survival curves were used to compare the cumulative removal rates of free implants with partially paid i…
Cost-effectiveness analysis of patent foramen ovale closure with Amplatzer plus medical therapy compared to medical therapy in patients with a histor…
2021
Abstract Background A patent foramen ovale (PFO) is formed when the ovale foramen does not close spontaneously or re-opens leaving the right and left atrium connected. The present study was conducted to analyze the cost-effectiveness of PFO closure with Amplatzer device plus medical therapy (MT) compared to MT alone in the French reimbursement system for PFO patients with a prior history of stroke, using the RESPECT study data. Methods A multi-state Markov model was used. The analysis was conducted from a collective perspective over a 10-year time horizon with 4% discount applied for costs and health effects. The simulated population included adult patients with PFO. Sub-group analysis was …
Effect of an intrauterine device on the gene expression profile of the endometrium.
2006
The human endometrium acquires the ability to allow embryo attachment just for a specific period of time during each menstrual cycle. Understanding of the opposite functional status, referred to as refractoriness, can potentially be used to improve receptivity in infertile patients or as an interceptive approach to prevent gestation.The objective of the study was to analyze the endometrial gene expression profile induced by an inert intrauterine device (IUD) at the time of implantation.We used a microarray containing more than 16,000 cDNAs to investigate the gene expression profile of receptive vs. refractory endometrium in the same women induced by the presence of an IUD. We compared the g…
Absolute Accelerometer-Based Intensity Prescription Compared to Physiological Variables in Pregnant and Nonpregnant Women
2020
Estimation of the intensity of physical activity (PA) based on absolute accelerometer cut points (Cp) likely over- or underestimates intensity for a specific individual. The purpose of this study was to investigate the relationship between absolute moderate intensity Cp and the first ventilatory threshold (VT1). A group of 24 pregnant and 15 nonpregnant women who performed a submaximal incremental walking test with measures of ventilatory parameters and accelerations from three different accelerometers on the wrist (ActiGraph wGT3X-BT, GENEActiv, Axivity AX3) and one on the hip (Actigraph wGT3X-BT) were analyzed. Cp were determined corresponding to 3 metabolic equivalents of task (MET), usi…
A European Study of the Performance and Safety of MINIject in Patients With Medically Uncontrolled Open-angle Glaucoma (STAR-II)
2020
Precis In this European study (STAR-II), MINIject, a novel, ab-interno, supraciliary MIGS device, effectively lowered intraocular pressure (IOP) and the need for IOP-lowering medications in patients with primary open-angle glaucoma. Purpose To evaluate the safety and performance of a minimally invasive supraciliary glaucoma drainage device (MINIject DO627, iSTAR Medical SA, Wavre, Belgium) for surgical treatment of primary open angle glaucoma in patients refractory to topical hypotensive medications. Methods In a prospective, interventional, single-arm, multi-center, European study (STAR-II), MINIject was successfully implanted in a standalone procedure in 29 of 31 patients in 8 sites in 3 …