Search results for " imaging."

showing 10 items of 6165 documents

Inflammatory Pseudotumor of Mediastinum Treated with Tomotherapy and Monitored with FDG-PET/CT: Case Report and Literature Review

2010

Mediastinal inflammatory pseudotumor is a rare disease with reactive pseudoneoplastic features and a proven capacity for local invasion. The radiographic appearance of inflammatory pseudotumor is quite non-specific and the definitive diagnosis is based on the histological evaluation of tissue specimens. Resection of the lesion is the treatment of choice. However, nonsurgical treatments such as radiotherapy and steroids have been employed in the setting of incomplete surgical resection, tumor recurrence, and patients being unfit for surgery. The case described here is being reported because of the rare mediastinal location and atypical treatment approach including salvage irradiation and mon…

AdultCancer Researchmedicine.medical_specialtyPET/CTRadiographymedicine.medical_treatmenttomotherapyAdult; Granuloma Plasma Cell; Humans; Mediastinal Neoplasms; Positron-Emission Tomography; Tomography X-Ray Computed; Fluorodeoxyglucose F18; RadiopharmaceuticalsMediastinal NeoplasmsGranuloma Plasma CellTomotherapy030218 nuclear medicine & medical imagingInflammatory pseudotumorLesion03 medical and health sciences0302 clinical medicineFluorodeoxyglucose F18HumansMedicineTomographyPET-CTGranulomabusiness.industryMediastinumGeneral MedicinemediastinumX-Ray ComputedRadiation therapymedicine.anatomical_structureOncologyPositron-Emission TomographyPlasma CellInflammatory pseudotumorRadiologyRadiopharmaceuticalsmedicine.symptomTomography X-Ray Computedbusiness030217 neurology & neurosurgeryRare diseaseTumori Journal
researchProduct

A new method for the placement of brachytherapy probes in paranasal sinus and nasopharynx neoplasms

1999

Abstract Purpose: In afterloading therapy, the exact placement of the applicator is crucial for the result of radiotherapy. A deviation of few millimeters from the target leads to a significant reduction of radiation energy to the tumor. Methods and Materials: We present a new method using a computer-assisted device for three-dimensional placing of afterloading probes based on CT scans that allows for the exact placement. Results: Target points have been reached with an accuracy of 0.6 mm. Since 1991 we have used this technique for 24 clinical applications in 11 patients with recurrent neoplasms in the region of the paranasal sinuses and nasopharynx for palliative treatment. Conclusions: Th…

AdultCancer Researchmedicine.medical_specialtyPalliative treatmentNasopharynx Neoplasmsmedicine.medical_treatmentBrachytherapyBrachytherapyHumansMedicineRadiology Nuclear Medicine and imagingSinus (anatomy)AgedRadiationbusiness.industryComputer aidCarcinomaNasopharyngeal NeoplasmsEquipment DesignMiddle AgedRadiotherapy Computer-AssistedRadiation therapymedicine.anatomical_structureParanasal sinusesOncologyCarcinoma Squamous CellRadiologyNeoplasm Recurrence LocalTomography X-Ray ComputedbusinessParanasal Sinus NeoplasmsInternational Journal of Radiation Oncology*Biology*Physics
researchProduct

A Case Report of Adult Pineoblastoma Occurring in a Pregnant Woman.

2019

Background/aim Pineoblastoma of the adult age is an uncommon tumor with only 200 cases reported. A standardized approach for an optimal adjuvant strategy is currently lacking. The case presented herein also deals with the issue of central nervous system tumors in pregnancy. Case report A 21-year-old pregnant woman presented with massive hydrocephalus due to a mass in the pineal region detected with MRI. After positioning an urgent ventricular derivation, a cesarean section was performed. During a third ventriculocisternostomy, a biopsy revealed a pineoblastoma. After a maximal safe resection, postoperative craniospinal irradiation for a total dose of 36 Gy plus a sequential boost to the tum…

AdultCancer Researchmedicine.medical_specialtyVincristinePineal GlandCraniospinal IrradiationVentriculostomy03 medical and health sciences0302 clinical medicinePregnancyBiopsyMedicineHumansPineoblastomaPregnancymedicine.diagnostic_testbusiness.industryCesarean SectionGestational ageGeneral MedicineChemoradiotherapy Adjuvantmedicine.diseaseMagnetic Resonance ImagingHydrocephalusAdult PineoblastomaTreatment OutcomeOncology030220 oncology & carcinogenesisFemaleRadiologybusinessPinealomaPregnancy Complications Neoplasticmedicine.drugAnticancer research
researchProduct

Primary Orbital Liposarcoma in Li-Fraumeni Cancer Family Syndrome: A Case Report

2005

Aims and background The aim of this study was to describe a case of primary orbital liposarcoma in Li-Fraumeni syndrome. Methods and study design In July 1998 a 20-year-old woman with a histological diagnosis of orbital myxoid liposarcoma underwent surgical treatment in our department. Since the patient's family pedigree met the clinical criteria for the diagnosis of LFS, molecular analysis was performed, which resulted in a molecular profile consistent with Li-Fraumeni syndrome. Results The patient underwent orbital exenteration extended to the upper eyelid; surgical reconstructive steps were performed to permit placement of an orbital prosthesis. Two years after primary surgery the patien…

AdultCancer Researchmedicine.medical_specialtymedicine.medical_treatmentBreast NeoplasmsLiposarcomaMalignancyliposarcoma Li-Fraumeni syndrome orbital surgery.030218 nuclear medicine & medical imagingLi-Fraumeni Syndrome03 medical and health sciences0302 clinical medicinemedicineHumansOrbital prosthesisFamily historyMyxoid liposarcomabusiness.industryLiposarcomaGeneral Medicinemedicine.diseaseSurgeryOncologyLi–Fraumeni syndrome030220 oncology & carcinogenesisOrbital NeoplasmsFemaleLymphadenectomybusinessQuadrantectomyTumori Journal
researchProduct

RCBF-quantification with 99mTc-HMPAO-SPECT: theory and first results.

1989

The activity concentrations of 99mTc-HMPAO in brain after intravenous injection were evaluated in 25 patients using SPECT. With additional first pass studies of heart and brain with the short lived isotope 195mAu, the cardiac output and the mean cerebral transit times of the patients were measured a short time before the HMPAO injection. The time dependence of 99mTc-HMPAO activity in the brain was registered during the first 5 min after injection over both hemispheres. Using a simplified three compartment model it was possible to calculate the mean retention fraction of HMPAO in brain from the time activity curves. It could be shown that the regional cerebral blood flow in ml/min per 100 g …

AdultCardiac outputCorrelation coefficientAdolescentHemodynamicsGrey matterTechnetium Tc 99m ExametazimeOximesmedicineOrganometallic CompoundsHumansRadiology Nuclear Medicine and imagingChild99mtc hmpao spectAgedmedicine.diagnostic_testbusiness.industryBrainTechnetiumGeneral MedicineMiddle Agedmedicine.anatomical_structureCerebral blood flowPositron emission tomographyCerebrovascular CirculationbusinessNuclear medicineTechnetium-99mTomography Emission-ComputedEuropean journal of nuclear medicine
researchProduct

Association of Left Ventricular Systolic Dysfunction Among Carriers of Truncating Variants in Filamin C With Frequent Ventricular Arrhythmia and End-…

2021

Importance: Truncating variants in the gene encoding filamin C (FLNCtv) are associated with arrhythmogenic and dilated cardiomyopathies with a reportedly high risk of ventricular arrhythmia.Objective: To determine the frequency of and risk factors associated with adverse events among FLNCtv carriers compared with individuals carrying TTN truncating variants (TTNtv).Design, Setting, and Participants: This cohort study recruited 167 consecutive FLNCtv carriers and a control cohort of 244 patients with TTNtv matched for left ventricular ejection fraction (LVEF) from 19 European cardiomyopathy referral units between 1990 and 2018. Data analyses were conducted between June and October, 2020.Main…

AdultCardiomyopathy DilatedMalemedicine.medical_specialtyFilaminsCardiomyopathy030204 cardiovascular system & hematologySudden cardiac deathVentricular Dysfunction Left03 medical and health sciences0302 clinical medicineInterquartile rangeCardiac magnetic resonance imagingInternal medicinemedicineHumansConnectin030212 general & internal medicineHeart FailureEjection fractionmedicine.diagnostic_testbusiness.industryHazard ratioCorrectionStroke Volume[SDV.MHEP.EM]Life Sciences [q-bio]/Human health and pathology/Endocrinology and metabolismMiddle Agedmedicine.diseaseDefibrillators Implantable3. Good healthDeath Sudden CardiacCodon NonsenseHeart failureMutationCohortTachycardia VentricularCardiologyHeart TransplantationFemaleCardiology and Cardiovascular MedicinebusinessJAMA Cardiology
researchProduct

Is local stiffness, as measured by radio frequency, more sensitive than intima-media thickness?

2013

Aim: The aim of our study was to explore the changes in common carotid arterial intima-media thickness (CCA IMT) and local arterial stiffness to evaluate, non-invasively, early vascular disease in patients with cardiovascular (CV) risk factors and "normal" carotid IMT (6.05 m/s better identified, among patients with IMT <0.9mm, those with cardiovascular risk factors (sensitivity 82.0 % specificity 62.0 %; AUC 0.73). Conclusion. Increased stiffness is a result of change both in quantity and quality of the arterial wall. Arterial functional changes and distention alterations may herald the onset of vascular disease before manifestation of symptoms or detection of preclinical atherosclerotic l…

AdultCarotid Artery DiseasesMaleCarotid Artery CommonMiddle AgedPulse Wave AnalysisCardiovascular diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolareCarotid Intima-Media ThicknessElasticityCarotid intima-media thickneYoung AdultVascular StiffnessROC CurvePredictive Value of TestsRisk FactorsArea Under CurveCase-Control StudiesVascular stiffneElasticity Imaging TechniquesHumansFemaleCardiology and Cardiovascular MedicineVascular stiffnessCarotid intima-media ticknesscardiovascular diseasesInternational angiology : a journal of the International Union of Angiology
researchProduct

Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla

2009

Summary Objective The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). Methods The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia…

AdultCartilage ArticularGadolinium DTPAMalemusculoskeletal diseasesdGEMRICmedicine.medical_specialtyIntraclass correlationBiomedical EngineeringContrast MediaKnee JointSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRheumatologymedicineHumansFemurOrthopedics and Sports MedicineTibiaRadionuclide Imaging030222 orthopedicsReproducibilitybusiness.industryCartilageReproducibility of ResultsMiddle AgedImage Enhancementmusculoskeletal systemMagnetic Resonance ImagingReproducibilityKnee jointSagittal planeCartilagemedicine.anatomical_structureProteoglycanFemalePatellaRadiologybusinessNuclear medicineOsteoarthritis and Cartilage
researchProduct

Assessment of normal patellar cartilage volume and thickness using MRI: an analysis of currently available pulse sequences.

1996

Objective. The objective of this study was to analyse the potential of magnetic resonance imaging for valid determination of patellar cartilage thickness, comparing currently available pulse sequences. Design. In six patients and one cadaver the cartilage was repetitively imaged employing three spin-echo and six three-dimensional gradient-echo sequences. In the cadaveric specimen the total volume and the regional distribution of cartilage thickness were assessed and compared with the values obtained from anatomical sections by image analysis. Results and conclusions. The FLASH and fat-suppressed FLASH sequences allowed the most accurate determination of the cartilage volume and thickness. F…

AdultCartilage ArticularMaleCadaverReference ValuesmedicineCadaverSynovial fluidHumansRadiology Nuclear Medicine and imagingReproducibilitymedicine.diagnostic_testbusiness.industryCartilageReproducibility of ResultsPulse sequenceMagnetic resonance imagingAnatomyPatellaMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structurePatellabusinessCadaveric spasmBiomedical engineeringSkeletal radiology
researchProduct

Facilitating cartilage volume measurement using MRI.

2010

To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses.Ten knees were scanned with a 1.5T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5mm, 3.0mm and 5.0mm slices using the Argus software application. Accuracy and time effectiveness served as control parameters.Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6+/-127.7s and 379.1+/-117.6s to 214.9+/-109.9s and 213.9+/-102.2s to 122.1+/-60.1s and 126.8+/-56.2s and for the medial tibial platea…

AdultCartilage ArticularMaleKnee JointLateral tibial plateauArticular cartilageYoung AdultVolume measurementImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingControl parametersObserver VariationTibiabusiness.industryCartilageGeneral MedicineAnatomyMagnetic Resonance Imagingmedicine.anatomical_structureFemalebusinessVolume (compression)Biomedical engineeringGradient echoEuropean journal of radiology
researchProduct