Search results for " ionization"
showing 10 items of 621 documents
Determination of bisphenol diglycidyl ether residues in canned foods by pressurized liquid extraction and liquid chromatography–tandem mass spectrome…
2005
Abstract A new confirmatory method for simultaneous determination of bisphenol diglycidyl ether residues (BADGE, BADGE·H2O, BADGE·2H2O, BADGE·H2O·HCl, BADGE·HCl, BADGE·2HCl, BFDGE and BFDGE·2HCl) from canned food has been developed. The proposed method includes extraction by pressurized liquid extraction (PLE) followed by liquid–liquid partition and purification by solid phase extraction (SPE). Several solvent systems and different operating conditions (time, temperature) have been investigated for PLE optimization. A reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to atmospheric pressure chemical ionisation tandem mass spectrometry (APCI-MS–MS) method was developed …
Making Broad Proteome Protein Measurements in 1−5 min Using High-Speed RPLC Separations and High-Accuracy Mass Measurements
2005
The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both…
Comparison of solid-phase microextraction and stir bar sorptive extraction for determining six organophosphorus insecticides in honey by liquid chrom…
2004
Abstract Two approaches based on sorptive extraction, solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE), in combination with liquid chromatography (LC)–atmospheric pressure chemical ionization mass spectrometry (MS) have been assayed for analyzing chlorpyriphos methyl, diazinon, fonofos, phenthoate, phosalone, and pirimiphos ethyl in honey. In both, SPME and SBSE, enrichment was performed using a poly(dimethylsiloxane) coating. Significant parameters affecting sorption process such as sample volume, sorption and desorption times, ionic strength, elution solvent, and dilution (water/honey) proportion were optimized and discussed. Performance of both methods has been …
A quantitative analysis of stratospheric HCl, HNO3, and O3 in the tropopause region near the subtropical jet
2014
The effects of chemical two-way mixing on the Extratropical Transition Layer (ExTL) near the subtropical jet are investigated by stratospheric tracer-tracer correlations. To this end, in situ measurements were performed west of Africa (25-32 ◦ N) during the Transport and Composition of the Upper Troposphere Lower Stratosphere (UTLS)/Earth System Model Validation (TACTS/ESMVal) mission in August/September 2012. The Atmospheric chemical Ionization Mass Spectrometer sampling HCl and HNO3 was for the first time deployed on the new German High Altitude and Long range research aircraft (HALO). Measurements of O3, CO, European Centre for Medium-Range Weather Forecasts (ECMWF) analysis, and the tig…
Determination of a three-step excitation and ionization scheme for resonance ionization and ultratrace analysis of Np-237
2011
Abstract The long-lived radio isotope 237 Np is generated within the nuclear fuel cycle and represents a major hazard in the final disposal of nuclear waste. Related geochemical research requires sensitive methods for the detection of ultratrace amounts of neptunium in environmental samples. Resonance ionization mass spectrometry (RIMS) has proven to be one of the most sensitive methods for the detection of plutonium. A precondition for the application of RIMS to ultratrace analysis of neptunium is the knowledge of an efficient and selective scheme for optical excitation and ionization. Therefore, a multitude of medium to high-lying atomic levels in neptunium was located by applying in-sour…
Measurements of HONO, NO, NOyand SO2in aircraft exhaust plumes at cruise
2011
Measurements of gaseous nitrogen and sulfur oxide emissions in young aircraft exhaust plumes give insight into chemical oxidation processes inside aircraft engines. Particularly, the OHA¢Â�Â�induced formation of nitrous acid (HONO) from nitrogen oxide (NO) and sulfuric acid (H2SO4) from sulfur dioxide (SO2) inside the turbine which is highly uncertain, need detailed analysis to address the climate impact of aviation. We report on airborne in situ measurements at cruise altitudes of HONO, NO, NOy, and SO2 in 9 wakes of 8 different types of modern jet airliners, including for the first time also an A380. Measurements of HONO and SO2 were made with an ITCIMS (Ion Trap Chemical Ionization Mass …
Pesticide residue determination in fruit and vegetables by liquid chromatography–mass spectrometry
2000
An overview is given of pesticide residue determination in fruit and vegetables by liquid chromatography-mass spectrometry (LC-MS). Emphasis is placed on the thermospray, particle beam and atmospheric pressure ionization interfaces including advantages and drawbacks and typical detection limits. The capacity of each interface to provide useful data for identification/confirmation of analytes and the possibility of obtaining structural information for the identification of target and non-target compounds is discussed. Finally, sample preparation techniques are dealt with in relation to their influence on further LC-MS determination.
Recent developments in resonance ionization mass spectrometry for ultra-trace analysis of actinide elements
2019
Abstract Resonance ionization mass spectrometry is an efficient tool to detect minute amounts of long-lived radio-isotopes in environmental samples. Applying resonant excitation and ionization with pulsed laser radiation within a hot cavity atomizer enables the sensitive detection and precise quantification of long-lived actinide isotopes. Due to the inherently element selective ionization process, this method ensures ultimate suppression of contaminations from other elements and molecules. The characterization of in-source resonance ionization of the actinide elements U, Th, Np, and Am using a compact quadrupole mass spectrometer (QMS) setup are discussed.
Some Observations on Recent Studies Concerning the Electron Ionization Mass Spectrometry of 4(3H)-Quinazolinones
1996
Studies in organic mass spectrometry. Part 24† Electron ionization mass spectra of some aryl(2-nitrobenzo[b]thiophen-3-yl)amines
1999
The main fragmentation routes of eighteen title compounds and of three 5-chloro derivatives have been investigated with the aid of linked scan (B/E = constant) spectrometry, accurate mass measurements and deuterium labelling. Copyright © 1999 John Wiley & Sons, Ltd.