Search results for " leakage"
showing 10 items of 86 documents
Sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel …
2011
Objectives: The aim of this study was to evaluate the sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium root canal instruments by fluid filtration method. Study design: The root canals were prepared with stainless steel (SS) and nickel titanium (NiTi) instruments. The canals prepared with SS were obturated with lateral compaction technique using .02 tapered cones and the canals prepared with NiTi instruments were obturated with lateral compaction technique using .02 tapered cones or 06 tapered single cones. The amount of leakage was evaluated by fluid filtration model. The results wer…
Comparative evaluation of the apical sealing ability of a ceramic based sealer and MTA as root-end filling materials : an in-vitro study
2017
Background The present study was aimed to evaluate and compare the apical sealing ability of two endodontic root-end filling materials namely, iRoot SP (ceramic based) and ProRoot MTA using the bacterial leakage system. Material and methods A total of fifty recently extracted, single rooted teeth with a single straight canal were selected for the study. The teeth were chemo mechanically prepared. The apical 3mm of the root was resected and root end cavities were prepared. The teeth were randomly divided into two groups of twenty teeth each for the experimental root end filling materials namely, iRoot SP and ProRoot MTA. A two-chamber model was constructed using pippeter tips and plastic via…
A low cost and easy re-configurable instrument for power quality survey
2004
In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.
Proceedings of the first international summit on intestinal anastomotic leak, Chicago, Illinois, October 4-5, 2012
2014
Item does not contain fulltext OBJECTIVE: The first international summit on anastomotic leak was held in Chicago in October, 2012 to assess current knowledge in the field and develop novel lines of inquiry. The following report is a summary of the proceedings with commentaries and future prospects for clinical trials and laboratory investigations. BACKGROUND: Anastomotic leakage remains a devastating problem for the patient, and a continuing challenge to the surgeon operating on high-risk areas of the gastrointestinal tract such as the esophagus and rectum. Despite the traditional wisdom that anastomotic leak is because of technique, evidence to support this is weak-to-non-existent. Outcome…
Effect of alkaline ph on sealing ability of white mineral trioxide aggregate
2011
Objectives: The aim of this study was to evaluate microleakage of white mineral trioxide aggregate (WMTA) after its exposure to a range of alkaline environments during hydration. Study Design: Seventy single-rooted teeth were divided into 4 experimental and 2 control groups. All the teeth were instrumented, and their apices were resected. Root-end cavities were filled with WMTA in the experimental groups. In the control groups, root-end cavities were not filled. Root-end fillings were exposed to alkaline environments with pH values of 7.4, 8.4, 9.4, or 10.4 for 3 days. Microleakage was evaluated by bovine serum albumin. Evaluations were carried out at 24-hour intervals for 80 days. Data wer…
Microleakage comparison of glass-ionomer and white mineral trioxide aggregate used as a coronal barrier in nonvital bleaching
2011
Objectives: There is some evidence that the pH at the root surface is reduced by intracoronal placement of bleaching pastes, which is known to enhance osteoclastic activity. Therefore, it is recommended that a protective barrier be used over the canal filling to prevent leakage of bleaching agents. Glass-ionomer (GI) is commonly used as a coronal barrier before nonvital bleaching. Because mineral trioxide aggregate (MTA) creates high alkalinity after mixing with water, using MTA as a protective barrier over the canal filling may not only prevent leakage of bleaching agents and microorganisms, but may prevent cervical resorption. The aim of this study was to evaluate sealing ability of white…
Effect of a plant-based hemostatic agent on microleakage of self-etching adhesives
2012
Objective: This in vitro study evaluated the effect of Ankaferd Blood Stopper (ABS) contamination on the micro-leakage of one-step and two-step self-etching adhesives.
Reduction of Polymerization Shrinkage Stress and Marginal Microleakage Using Soft-Start Polymerization
2003
Purpose: This study evaluated the influence of a soft-start light-curing exposure on polymerization shrinkage stress and marginal integrity of adhesive restorations. Materials and Methods: Six resin-based composites (Pertac II, Tetric Ceram, Definite, Surefil, Solitaire, and Visio-Molar) were adhesively bonded to a cylindrical cavity (n = 9 per material/light) in a photoelastic material. Visible light-curing was applied using either the standard polymerization mode (800 mW/cm2 exposure duration 40 s) of the curing light (Elipar TriLight, 3M ESPE) or the exponential mode from the same device (ramp-curing: 150 mW/cm2 to 800 mW/cm2 within the first 15 s of a total curing time of 40 s). Polymer…
Unifying Concepts for Ion-Induced Leakage Current Degradation in Silicon Carbide Schottky Power Diodes
2020
The onset of ion-induced reverse leakage current in SiC Schottky diodes is shown to depend on material properties, ion linear energy transfer (LET), and bias during irradiation, but not the voltage rating of the parts. This is demonstrated experimentally for devices from multiple manufacturers with voltage ratings from 600 to 1700 V. Using a device with a higher breakdown voltage than required in the application does not provide increased robustness related to leakage current degradation, compared to using a device with a lower voltage rating.
Heavy-Ion-Induced Degradation in SiC Schottky Diodes : Incident Angle and Energy Deposition Dependence
2017
International audience; Heavy-ion-induced degradation in the reverse leakage current of SiC Schottky power diodes exhibits a strong dependence on the ion angle of incidence. This effect is studied experimentally for several different bias voltages applied during heavy-ion exposure. In addition, TCAD simulations are used to give insight on the physical mechanisms involved.