Search results for " light"
showing 10 items of 1141 documents
A laboratory setup for the evaluation of the effects of BACS and TBM systems on lighting
2015
The paper focuses on the evaluation of the impact of Building Automation Control Systems (BACS) and Technical Building Management (TBM) systems on the performance of the lighting system in a residential building. In particular, this work shows a laboratory setup, installed at the DEIM of the University of Palermo, for simulating a typical apartment. The paper describes the laboratory, the lighting system and the BAC system installed and the test facility for evaluating the electricity consumption in presence and in absence of automation. The laboratory has been built within a research project funded by the Italian Minister of University and Research in the framework of the PON Smart Cities …
Improvement of Energy Efficiency for Indoor Lighting in a Big Shopping Center
2018
As the progressive diffusion of shopping centers in Italy, the paper analysis the potential energy savings in the indoor lighting plant, thanks to new technologies as LED lamps and Building Automation System. The case study, applied to a big shopping mall in the middle of Italy, shows great results, thanks to the high efficiency of LED technology, high number of operating hours and the implementation of a control system. An economic and environmental evaluation is reported.
On the impact of safety requirements, energy prices and investment costs in street lighting refurbishment design
2018
Abstract Street lighting is an indispensable feature for the night landscape of cities. It is important for road safety, users visual comfort, crime prevention and to augment the perceived personal safety. Realize and maintain an adequate street lighting service is very expensive for municipalities with significant impact on their budgets. For this reason, special attention should be paid to the design of new street lighting systems and to the refurbishment of existing ones, since many of them are inadequate. In light of this it is very important to implement street lighting designs that fulfil lighting requirements avoiding energy waste and light pollution and, at the same time, result eco…
Methods to Evaluate Lighting Quality in Educational Environments
2015
Abstract The current standard for lighting of indoor work places (EN 12464-1) essentially prescribes values of photometric quantities (illuminance, Unified Glare Index, etc.); therefore it does not allow a comprehensive analysis of the luminous environment. In Italy, educational buildings do not always comply with the standard requirements for lighting. Therefore an analysis of their current state is needed and this paper illustrates two methods, developed by the authors, to carry out this investigation: the former is based on the analysis of luminance maps obtained through the HDR imaging technique whereas the latter focuses on the evaluation of non-visual effects of light.
Special Issue “Smart Urban Lighting Systems”
2020
The design and operation of multifunctional infrastructures for public lighting as well as their impact on the urban environment and citizens’ life is today of great interest. The cost of energy for public lighting is often an issue for the budget of municipalities. Furthermore, researchers’ and designers’ attention is increasingly focused on aspects of public lighting not directly valuable through economic factors. Starting from the “quality” of the light environment, looking at citizens’ visual comfort, the light has to be considered as an instrument to improve the urban context and objects therein (including buildings). Indeed, urban degradation (lack of infrastructures, maintenance, ser…
INFγ stimulates arginine transport through system y+L in human monocytes
2004
Freshly isolated human monocytes transport L-arginine mostly through a sodium independent, NEM insensitive pathway inhibited by L-leucine in the presence, but not in the absence of sodium. Interferon-gamma (IFNgamma) stimulates this pathway, identifiable with system y+L, and markedly enhances the expression of SLC7A7, the gene that encodes for system y+L subunit y+LAT1, but not of SLC7A6, that codes for the alternative subunit y+LAT2. System y+ plays a minor role in arginine uptake by monocytes and the expression of system y+-related genes, SLC7A1 and SLC7A2, is not changed by IFNgamma. These results demonstrate that system y+L is sensitive to IFNgamma.
Efficient ultraviolet-light energy dissipation by an aromatic ketone.
2010
Experimental evidence on the efficiency of 2,2'4,4'-tetramethoxybenzil for UV-light energy dissipation is provided. This non-phenolic aromatic ketone has a low energy triplet which quickly decays to the ketone ground state, thus avoiding the generation of undesirable reactive species. El Moncef, Abdelkarim, elmonab@alumni.uv.es ; Cuquerella Alabort, Maria Consuelo, Chelo.Cuquerella@uv.es ; Zaballos Garcia, Elena, Elena.Zaballos@uv.es ; Ramirez de Arellano Sanchez, Maria del Carmen, Carmen.Ramirezdearellano@uv.es ; Stiriba, Salah Eddine, Salah.Stiriba@uv.es ; Perez Prieto, Julia, Julia.Perez@uv.es
L’art. 28 dello Statuto e le trasformazioni del lavoro: cinquant’anni portati bene, ma non troppo
2020
L’art. 28 dello Statuto dei lavoratori ha attraversato un cinquantennio di storia del conflitto sindacale italiano. Si tratta di un rimedio ancora attuale, che necessità di un intervento manutentivo alla luce delle trasformazioni del diritto del lavoro. Partendo dalla validità del modello normativo, il saggio individua le criticità per il legislatore in una prospettiva de jure condendo.
Midinfrared FT-IR as a Tool for Monitoring Herbaceous Biomass Composition and Its Conversion to Furfural
2015
A semiquantitative analysis by means of midinfrared FT-IR spectroscopy was tuned for the simultaneous determination of cellulose, hemicellulose, and lignin in industrial crops such as giant reed (Arundo donaxL.) and switchgrass (Panicum virgatumL.). Ternary mixtures of pure cellulose, hemicellulose, and lignin were prepared and a direct correlation area/concentration was achieved for cellulose and lignin, whereas indirect correlations were found for hemicellulose quantification. Good correspondences between the values derived from our model and those reported in the literature or obtained according to the official Van Soest method were ascertained. Average contents of 40–45% of cellulose, 2…
Study of ambient light influence for three-dimensional scanners based on structured light
2007
Ambient light in a scene can introduce errors into range data from most commercial three-dimensional range scanners, particularly scanners that are based on projected patterns and structured lighting. We study the effects of ambient light on a specific commercial scanner. We further present a method for characterizing the range accuracy as a function of ambient light distortions. After a brief review of related research, we first describe the capabilities of the scanner we used and define the experimental setup for our study. Then we present the results of the range characterization relative to ambient light. In these results, we note a systematic error source that appears to be an artifact…