Search results for " microscopy"
showing 10 items of 1617 documents
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…
Operation conditions and stability of a degenerate two-photon laser
1993
Abstract The presence of a far off-resonant intermediate level in a degenerate three-level two-photon laser model manifests through a steady pump-dependent and a dynamic frequency shift on the laser equations. The steady shift strongly affects the pump threshold necessary for emission, preventing it in certain cases. The dynamic shift makes the frequency pulling/pushing to be intensity-dependent and substantially modify the domains of existence and stability of the lasing solution permitting stable operation for large cavity losses in certain cases.
Superresolved imaging in digital holography by superposition of tilted wavefronts
2006
A technique based on superresolution by digital holographic microscopic imaging is presented. We used a two dimensional (2-D) vertical-cavity self-emitting laser (VCSEL) array as spherical-wave illumination sources. The method is defined in terms of an incoherent superposition of tilted wavefronts. The tilted spherical wave originating from the 2-D VCSEL elements illuminates the target in transmission mode to obtain a hologram in a Mach-Zehnder interferometer configuration. Superresolved images of the input object above the common lens diffraction limit are generated by sequential recording of the individual holograms and numerical reconstruction of the image with the extended spatial frequ…
DarkFocus: numerical autofocusing in digital in-line holographic microscopy using variance of computational dark-field gradient
2020
Abstract We report on a novel computational technique for automatic numerical refocusing in digital in-line holographic microscopy. It is based on the adaptive filtering of the recorded on-axis hologram to eliminate its background term and extract interference intensity-component connected with light scattered on the sample (interference fringes). Numerical propagation of such filtered hologram yields the computationally generated dark-field imaging coming from the amplitude part of the complex field. We propose a simple measure in the form of the variance of the dark-field gradient, which attains its maximum value in the focal planes for all types of objects (phase, amplitude and mixed pha…
Optically-undistorted digital holographic microscopy for quantitative phase-contrast imaging
2011
We propose a telecentric architecture for circumventing, by a pure-optical method, the residual phase distortion inherent to standard configuration of digital holographic microscopy (DHM). With this proposal there is no need for computer compensation of the parabolic phase during the phase map recovering procedure. Futhermore, in off-axis configuration, the spatial frequency useful domain is enlarged. The validity of the method is demonstrated by performing quantitative measurements of depth differences
Resolution improvement by single-exposure superresolved interferometric microscopy with a monochrome sensor
2011
Single-exposure superresolved interferometric microscopy (SESRIM) by RGB multiplexing has recently been proposed as a way to achieve one-dimensional superresolved imaging in digital holographic microscopy by a single-color CCD snapshot [Opt. Lett. 36, 885 (2011)]. Here we provide the mathematical basis for the operating principle of SESRIM, while we also present a different experimental configuration where the color CCD camera is replaced by a monochrome (B&W) CCD camera. To maintain the single-exposure working principle, the object field of view (FOV) is restricted and the holographic recording is based on image-plane wavelength-dispersion spatial multiplexing to separately record the thre…
PEEM with high time resolution—imaging of transient processes and novel concepts of chromatic and spherical aberration correction
2006
The potential of time-resolved photoemission electron microscopy (PEEM) for imaging ultrafast processes and for aberration correction in full-field imaging is discussed. In particular, we focus on stroboscopic imaging of precessional magnetic excitations via XMCD-PEEM exploiting the time structure of synchrotron radiation (magnetic field pulse pump–X-ray probe). In a special bunch-compression mode at BESSY, a time resolution of about 15 ps has been obtained. Further, we discuss an all-optical pump–probe technique using femtosecond laser excitation. A highly promising alternative to stroboscopic imaging is an approach using time-resolved image detection. As a second application of time-resol…
Time-resolved photoemission electron microscopy of magnetic field and magnetisation changes
2003
Owing to its parallel image acquisition, photoemission electron microscopy is well suited for real-time observation of fast processes on surfaces. Pulsed excitation sources like synchrotron radiation or lasers, fast electric pulsers for the study of magnetic switching, and/or time-resolved detection can be utilised. A standard approach also being used in light optical imaging is stroboscopic illumination of a periodic (or quasi-periodic) process. Using this technique, the time dependence of the magnetic field in a pulsed microstrip line has been imaged in real time exploiting Lorentz-type contrast. Similarly, the corresponding field-induced changes in the magnetisation of cobalt microstruct…
Dynamic deformation of migratory efferent lymph-derived cells ?trapped? in the inflammatory microcirculation
2002
The cellular immune response depends on the delivery of lymphocytes from the lymph node to the peripheral site of antigenic challenge. During their passage through the inflammatory microcirculaton, the migratory cells can become transiently immobilized or "trapped" in small caliber vessels. In this report, we used intravital microscopy and temporal area mapping to define the dynamic deformation of efferent lymph-derived mononuclear cells trapped in the systemic inflammatory microcirculation. Mononuclear cells obtained from the efferent lymph draining the oxazolone-stimulated microcirculation were labeled with fluorescent dye and reinjected into the feeding arterial circulation. Intravital v…
Biosilicification of loricate choanoflagellate: organic composition of the nanotubular siliceous costal strips of Stephanoeca diplocostata.
2010
SUMMARY Loricate choanoflagellates (unicellular, eukaryotic flagellates; phylum Choanozoa) synthesize a basket-like siliceous lorica reinforced by costal strips (diameter of approximately 100 nm and length of 3 μm). In the present study, the composition of these siliceous costal strips is described, using Stephanoeca diplocostata as a model. Analyses by energy-dispersive X-ray spectroscopy (EDX), coupled with transmission electron microscopy (TEM), indicate that the costal strips comprise inorganic and organic components. The organic, proteinaceous scaffold contained one major polypeptide of mass 14 kDa that reacted with wheat germ agglutinin. Polyclonal antibodies were raised that allowed …