Search results for " particles"
showing 10 items of 6711 documents
Two-neutron correlations at small relative momenta in ^40Ar + ^197Au collisions at 60 MeV/nucleon
2000
Two-neutron correlation functions are measured in the 40Ar + 197Au reaction at 60 MeV/nucleon to study the space-time characteristics of neutron emitting sources. The source temperatures and velocities are deduced by fitting the single-neutron energy spectra with a three-source model. A comparison of the correlation data with the predictions of the model of moving sources and with the dynamical Landau-Vlasov model suggests the relevance of a multisource description. Particular care has been paid to the influence of the relative source abundance on the shape of the correlation function.
Radiation hardness studies of CdTe and for the SIXS particle detector on-board the BepiColombo spacecraft
2009
Abstract We report of the radiation hardness measurements that were performed in the developing work of a particle detector on-board ESA's forthcoming BepiColombo spacecraft. Two different high- Z semiconductor compounds, cadmium telluride (CdTe) and mercuric iodide (HgI 2 ), were irradiated with 22 MeV protons in four steps to attain the estimated total dose of 10 12 p / cm 2 for the mission time. The performance of the detectors was studied before and after every irradiation with radioactive 55 Fe source Mn K α 5.9 keV emission line. We studied the impact of the proton beam exposure on detector leakage current, energy resolution and charge collection efficiency (CCE). Also the reconstruct…
Risk Assessment of Electron Induced SEE during the JUICE Mission
2018
The SEE sensitivity of electronic devices to high energy electrons has been put in evidence experimentally. Several ground experiments have shown that electron induced SEE could occur in recent technologies. In the case of the JUICE mission, the expected electron environment is harsher than for Earth orbits. The impact of such electron fluxes on the embedded electronics was assessed in this work. The study focused on SRAM memories SEU sensitivity. Three different device references were tested under electrons, as well as under protons and heavy ions. The electron and the low energy proton direct ionization contributions to the total SEU rate have been studied in more detail.
Silicon dosimeters based on Floating Gate Sensor: design, implementation and characterization
2020
A rad-hard monolithic dosimeter has been implemented and characterized in a standard 180 nm CMOS technology. The radiation sensor (C-sensor) is based on a Floating Gate (FG) MOS discharge principle. The output current is processed by a current-to-voltage (I/V) interface and then converted by a 5-bit flash ADC. The dosimeter is re-usable (FG can be recharged) and can detect a dose up to 1krad (Si) with a resolution of 30rad (Si) typical over temperature 0 to 85°C range. The ADC allows easy further signal processing for calibration and averaging, etc. The power consumption of C-sensor plus I/V interface is < 2mW from a 5 V power supply. The overall layout area is less than 0.25mm2. The Rad…
D0D0π+ mass distribution in the production of the Tcc exotic state
2021
Measurement of the branching fraction for ψ(3686)→ωKS0KS0
2021
α -nucleus optical potentials from chiral effective field theory NN interactions
2022
Contextuality-by-Default: A Brief Overview of Ideas, Concepts, and Terminology
2016
This paper is a brief overview of the concepts involved in measuring the degree of contextuality and detecting contextuality in systems of binary measurements of a finite number of objects. We discuss and clarify the main concepts and terminology of the theory called “contextuality-by-default,” and then discuss generalizations of the theory to arbitrary systems of arbitrary random variables.