Search results for " photomultiplier"
showing 10 items of 97 documents
Characterization of SiPM properties at liquid nitrogen temperature
2016
SiPM operation at cryogenic temperatures fails for many common devices. A particular type with deep channels in the silicon substrate instead of quenching resistors was thoroughly characterized from room temperature down to liquid nitrogen temperature by illuminating it with low light levels. The devices were mounted in vacuum with the temperature stabilized to allow long-term operation. SiPM signals from a LED pulser were acquired with single-pixel resolution. Generalized fits to the charge collection spectra were used to extract properties like single-pixel gain, inter-pixel variation, breakdown voltage, and photon detection efficiency. With these measurements a deeper investigation of th…
Performance of sensl C-Series SiPM with high photoelectron resolution at cryogenic temperatures
2016
The C-Series of silicon photomultipliers (SiPM) from SensL provides devices with a fast response and high performance at low cost. The device's ability to detect light at temperatures of liquid nitrogen (77K) and liquid helium (4 K) with high photoelectron resolution was demonstrated. Results include relative photon detection efficiency (PDE), gain, microcell capacitance, and cross-talk probability at different over-voltages, both at room and at cryogenic temperatures. At 77K the SiPM demonstrated significantly improved operating characteristics while at 4K the observed increase in break-down voltage, the reduction of PDE by a factor of 2-3, and the extensively dropped microcell capacitance…
Study of Large Hemispherical Photomultiplier Tubes for the ANTARES Neutrino Telescope
2005
The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a 3 dimensional matrix of 900 large area photomultiplier tubes housed in pressure resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the PMT chosen for ANTARES.
Performance of the front-end electronics of the ANTARES neutrino telescope
2010
ANTARES is a high-energy neutrino telescope installed in the Mediterranean Sea at a depth of 2475 m. It consists of a three-dimensional array of optical modules, each containing a large photomultiplier tube. A total of 2700 front-end ASICs named Analogue Ring Samplers (ARS) process the phototube signals, measure their arrival time, amplitude and shape as well as perform monitoring and calibration tasks. The ARS chip processes the analogue signals from the optical modules and converts information into digital data. All the information is transmitted to shore through further multiplexing electronics and an optical link. This paper describes the performance of the ARS chip; results from the fu…
Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs
2011
International audience; A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm×18 mm×5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 keV is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising res…
High resolution detectors based on continuous crystals and SiPMs for small animal PET
2012
International audience; Sensitivity and spatial resolution are the two main factors to maximize in emission imaging. The improvement of one factor deteriorates the other with pixelated crystals. In this work we combine SiPM matrices with monolithic crystals, using an accurate γ-ray interaction position determination algorithm that provides depth of interaction. Continuous crystals provide higher sensitivity than pixelated crystals, while an accurate interaction position determination does not degrade the spatial resolution. Monte Carlo simulations and experimental data show good agreement both demonstrating sub-millimetre intrinsic spatial resolution. A system consisting in two rotating det…
On the performances of a particle tracking detector based on triangular scintillator bars read out by silicon photomultipliers
2020
Abstract A tracking detector composed of scintillator bars with a triangular cross-section read out by silicon photomultipliers in analog mode was developed. The tracker was designed to instrument a low density spectrometer for neutrino experiments. The performance of the system has been studied by exposing it to charged particle beams at the CERN-PS. The tests have shown that the position resolution in reconstructing charged particles’ tracks is within 2.2 mm over the momentum range 0.5–10 GeV/c.
First Compton telescope prototype based on continuous LaBr3-SiPM detectors
2013
Abstract A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16×18×5 mm 3 LaBr 3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3×3 mm 3 in a 4.5×4.05 mm 2 pitch. The second detector, selected by availability, consists of a continuous 16×18×5 mm 3 LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a 22 Na source placed at different positions and images have been reconstructed with…
High performance detector head for PET and PET/MR with continuous crystals and SiPMs
2012
International audience; A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm source continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22Na sources. An image reconstruction method specifically adapted for continuous crystals has been emp…
Si photomultipliers for bio-sensing applications
2016
In this paper, silicon photomultipliers (SiPM) are proposed as optical detectors for bio sensing. Optical transduction is the most used detection mechanism in many biosensor applications, such as DNA microarray and real-time polymerase chain reaction. The performances of a 25 pixels device used for both applications are studied. The results confirm that the SiPM is more sensitive than the traditionally employed detectors. In fact, it is able to experimentally detect 1 nM and 100 fM of fluorophore concentrations in dried samples and solutions, respectively. We present and discuss in details the detector configuration and its characterization as fluorescence detector for bio sensing.