Search results for " photonic"

showing 10 items of 720 documents

Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.

2002

ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…

AdultMaleOptics and Photonicsgenetic structuresmedicine.medical_treatmentVisual AcuityEmmetropiaPhotorefractive Keratectomychemistry.chemical_compoundCorneaMyopiaHumansMedicineVision OcularRetinabusiness.industryRetinaleye diseasesPhotorefractive keratectomyVisual fieldOphthalmologymedicine.anatomical_structureMeridian (perimetry visual field)chemistrySensory ThresholdsVisual Field TestsOptometryFemaleLasers ExcimerSurgerysense organsVisual FieldsbusinessPhotopic vision
researchProduct

A Passive-Marker-Based Optical System for Computer-Aided Surgery in Otorhinolaryngology: Development and First Clinical Experiences

1999

Objectives: To develop a new type of optical computer-aided surgery (CAS) device that overcomes some of the restrictions of common systems and to examine its accuracy and usability under laboratory and intraoperative conditions. Study Design: Prospective study using laboratory experiments and intraoperative data collection. Methods: An optical CAS system applying passive optical markers for coordinate determination was developed. Laboratory accuracy measurements were obtained on a Plexiglas model with known coordinates of fiducial markers, before and after predefined table movements. Intraoperative accuracy measurements were recorded from 24 patients undergoing endonasal surgery of the para…

AdultMaleOptics and Photonicsmedicine.medical_specialtyEndoscopemedicine.medical_treatmentNasal PolypsParanasal SinusesmedicineHumansSinusitisbookMouthpieceComputer-assisted surgerybusiness.industryPassive markerComputer aided surgeryOtorhinolaryngologic Surgical ProceduresSurgeryImage-guided surgeryOtorhinolaryngologyOtorhinolaryngologyTherapy Computer-Assistedbook.journalFemaleFiducial markerNuclear medicinebusinessThe Laryngoscope
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator

2013

PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …

AdultMalePoint spread functionOptics and PhotonicsDepth of focusmedicine.medical_specialtymedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis Designlaw.inventionContrast SensitivityYoung AdultOpticslawOptical transfer functionOphthalmologymedicineHumansComputer SimulationAdaptive opticsLenses IntraocularPhysicsDepth PerceptionMonocularbusiness.industryAccommodation OcularStrehl ratioLens (optics)OphthalmologyFemalebusinessOptometryOptometry and Vision Science
researchProduct

Standing up from a chair as a dynamic equilibrium task: a comparison between young and elderly subjects.

2000

The purpose of this study was to analyze and compare the features of center of mass (CoM) control along anterior/posterior axis in young and elderly subjects during sit-to-stand (STS). From a sitting position, seven healthy young subjects and seven healthy elderly subjects were asked to stand up from a chair under different experimental conditions (visual conditions: normal and blindfolded; speed: normal and as fast as possible). Analysis of results was based upon the concept of a “dynamic equilibrium area” (DEA), which in turn identified the dynamic limits of balance. The results showed that both the maximal CoM velocity in the horizontal axis and the CoM velocity at the instant of seat-of…

AdultMalemedicine.medical_specialtyAgingOptics and PhotonicsTime FactorsBody heightMovementeducationPostureSittingBase of supportDisplacement (vector)Motion (physics)Physical medicine and rehabilitationTask Performance and AnalysisMedicineHumansPostural BalanceVision OcularBalance (ability)AgedHorizontal axisAged 80 and overLegbusiness.industryBody WeightHealthy elderlyhumanitiesBody HeightLinear ModelsFemaleStress MechanicalGeriatrics and GerontologyElectronicsbusinesshuman activitiesAlgorithmsThe journals of gerontology. Series A, Biological sciences and medical sciences
researchProduct

Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

2013

PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …

AdultMalemedicine.medical_specialtyBiopticsOptics and PhotonicsPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentImplantable Collamer Lens (ICL)Keratomileusis Laser In SituVisual AcuityKeratomileusisAstigmatismExcimerPhakic intraocular lensRefraction OcularPhotorefractive KeratectomyCellular and Molecular NeuroscienceYoung AdultOpticsBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansDioptreImplantable collamer lensScience & TechnologyExcimer laserbusiness.industryAstigmatismMiddle Agedmedicine.diseaseSensory SystemsPhotorefractive keratectomyeye diseasesOphthalmologyImplantable Collamer LensTreatment OutcomeFemalebusinessGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

2013

To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…

AdultMicrosurgeryOptics and PhotonicsPhakic Intraocular LensesVisual acuityAdolescentgenetic structuresComputer sciencemedia_common.quotation_subjectVisual AcuityPhakic intraocular lensPupilYoung AdultLens Implantation IntraocularOptical transfer functionmedicineHumansContrast (vision)Prospective StudiesAdaptive opticsVision OcularSimulationDioptremedia_commonAberrometryStrehl ratioeye diseasesRefractive Surgical ProceduresOphthalmologysense organsmedicine.symptomAmerican Journal of Ophthalmology
researchProduct

The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing

2018

Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…

AdultOptics and PhotonicsOriginal articleCorneal Wavefront AberrationVisual AcuityStarburstDiameter pupilRefraction Ocular050105 experimental psychology03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyError refractivoVisión nocturnaAberración esféricalcsh:QC350-467Humans0501 psychology and cognitive sciencesSpherical aberrationNight visionPhysicsResoluciónRefractive error05 social sciencesMiddle AgedRefractive ErrorsDetecciónDetectionlcsh:RE1-994030221 ophthalmology & optometryResolutionHumanitieslcsh:Optics. LightPhotic StimulationOptometryJournal of Optometry
researchProduct

Bis(oxazoline) Lewis Acid Catalyzed Aldol Reactions of PyridineN-Oxide Aldehydes—Synthesis of Optically Active 2-(1-Hydroxyalkyl)pyridine Derivatives…

2006

A new, short, and simplified procedure for the synthesis of optically active pyridine derivatives from pro-chiral pyridine-N-oxides is presented. The catalytic and asymmetric Mukaiyama aldol reaction between ketene silyl acetals and 1-oxypyridine-2-carbaldehyde derivatives catalyzed by chiral copper(II)-bis(oxazoline) complexes gave optically active 2-(hydroxyalkyl)- and 2-(anti-1,2-dihydroxyalkyl)pyridine derivatives in good yields and diastereoselectivities, and in excellent enantioselectivities-up to 99 % enantiomeric excess. As a synthetic application of the developed method, a full account for the asymmetric total synthesis of a nonnatural indolizine alkaloid is provided.

AldehydesOptics and PhotonicsPyridinesChemistryOrganic ChemistryIndolizinesEnantioselective synthesisTotal synthesisPyridine-N-oxideStereoisomerismGeneral ChemistryOxazolineCatalysisCyclic N-OxidesChemistrychemistry.chemical_compoundAlkaloidsAldol reactionPyridineOrganic chemistryIndolizineEnantiomeric excessAcidsChemistry - A European Journal
researchProduct

Beneficial impact of wave-breaking for coherent continuum formation in normally dispersive nonlinear fibers

2008

International audience; We study the evolution of a pulse propagating in a normally dispersive fiber in the presence of Kerr nonlinearity. We review the temporal and spectral impact of optical wave-breaking in the development of a continuum. The impact of linear losses or gain is also investigated.

Amplified spontaneous emissionOptical fiberPhysics::Optics02 engineering and technology01 natural scienceslaw.invention010309 optics020210 optoelectronics & photonicsOpticsliquid waves; oceanography; dispersive fiberlaw0103 physical sciences0202 electrical engineering electronic engineering information engineeringoceanographyliquid wavesPhysics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]dispersive fiberContinuum (measurement)business.industryNonlinear opticsBreaking waveStatistical and Nonlinear PhysicsPulse shapingAtomic and Molecular Physics and OpticsNonlinear systembusinessPhotonic-crystal fiber
researchProduct