Search results for " resin"
showing 10 items of 268 documents
Synthesis and characterisation of ordered arrays of mesoporous carbon nanofibres
2009
A facile and reproducible one-step pathway has been developed for preparing ordered arrays of mesoporous carbon nanostructures within the pores of anodized aluminium oxide (AAO) membranes, through the confined self-assembly of phenol/formaldehyde resol and amphiphilic copolymer templates. The morphology of the mesoporous carbon nanostructures can be controlled by varying the copolymer surfactant, the quantity of the resol–surfactant precursor sol used and the amount of phenol–formaldehyde resol introduced into the resol–surfactant sol. One-dimensional (1-D) carbon nanostructures, such as carbon fibres with a core–shell structure and carbon ribbons with circular mesopores running parallel to…
Bond strength of a new Kevlar fiber-reinforced composite post with semi-interpenetrating polymer network (IPN) matrix
2019
Background This study aimed to evaluate the bond strength and the penetration depth of two adhesive systems to a new experimental semi-IPN fiber post versus a commercial post. Material and Methods Experimental Kevlar fiber (KF) and control everStick®POST (ES) posts (n=20/ group) with a diameter of 1.5 mm were used, 10 posts coated with StickResin (SR) and the other 10 posts coated with Scotch bond multipurpose (SBMP) adhesives. Composite resin buildup was performed over each post, using a cylindrical plastic mold (10 mm × 6 mm). Four discs of 2 mm thickness were prepared from each post/composite buildup and underwent pushout bond strength test at a crosshead speed of 0.5 mm/min accompanied …
Elastic wave propagation in bone in vivo: methodology.
1995
The purpose of this study was to investigate the usefulness of elastic wave propagation (EWP) in estimating the mechanical properties (elasticity) of human tibia. The test group was composed of 78-yr-old women assigned to high (n = 19) and low (n = 17) bone mineral density (BMD) groups as measured at the calcaneus by the 125I-photon absorption method. The EWP apparatus consisted of an impact-producing hammer with a force strain gauge and two accelerometers positioned on the bone. Results for nylon and acrylic were used to calibrate the apparatus. Polyvinyl chloride (PVC) solid rods and tubes of various diameters were used to evaluate the relationship between the elastic wave velocity and cr…
Electromagnetic shielding efficiency in Ka-band: carbon foam versus epoxy/carbon nanotube composites
2012
The wide application of microwaves stimulates searching for new materials with high electrical conductivity and electromagnetic (EM) interference shielding effectiveness (SE). We conducted a comparative study of EM SE in K a -band demonstrated by ultra-light micro-structural porous carbon solids (carbon foams) of different bulk densities, 0.042 to 0.150 g/cm 3 , and conventional flexible epoxy resin filled with carbon nanotubes (CNTs) in small concentrations, 1.5 wt.%. Microwave probing of carbon foams showed that the transmission through a 2 mm-thick layer strongly decreases with decreasing the pore size up to the level of 0.6%, due to a rise of reflectance ability. At the same time, 1 mm…
Cytotoxicity of Root Canal Filling Materials to Three Different Human Cell Lines
2001
The aim of this study was to investigate the biological compatibility of five root canal sealers (Sealapex, Endion, Super-EBA, Ketac-Endo, and AH Plus) and regular and calcium hydroxide-based gutta-percha in three different human cell lines. Cultures without root canal sealers were used as controls. Cell growth, cell morphology, cell viability, protein content of the cells, and prostaglandin E 2 (PGE 2 ) release were used as parameters to determine the cytotoxicity of the materials. The protein content of the three cell lines—nasal fibroblasts, gingival fibroblasts, and epithelial tumor cells—was significantly reduced (p ≤ 0.001) by all materials tested. Determinations of PGE 2 release show…
Effect of cavity preparation instruments (oscillating or rotating) on the composite-dentin interface in primary teeth.
2003
Abstract Objectives: To evaluate the effect of preparation of instruments on the interfacial integrity between cavity wall and composite restoration. Methods: Two class II slot preparations were done in 10 primary teeth either with SonicSys® or with a conventional bur. The cavities were filled using an adhesive system. One layer of a flowable composite and one layer of a condensable composite were applied. The specimens were analyzed by confocal laser scanning microscopy. Results: In the SonicSys® group the mean thickness of the hybrid layer was 6.12 (0.60) μm; in the control group it was 6.04 (0.63) μm. The difference was not statistically significant. Two fractures were observed in one to…
Effect of aluminum chloride hemostatic agent on microleakage of class V composite resin restorations bonded with all-in-one adhesive
2012
Objectives: Since hemostatic agents can induce changes on enamel and dentin surfaces and influence composite resin adhesion, the aim of the present study was to evaluate the effect of the aluminum chloride hemostatic agent on the gingival margin microleakage of class V (Cl V) composite resin restorations bonded with all-in-one adhesive. Study design: Cl V cavities were prepared on the buccal surfaces of 60 sound bovine permanent incisors. Gingival margins of the cavities were placed 1.5 mm apical to the cemento-enamel junction (CEJ). The teeth were randomly divided into two groups of 30. In group 1, the cavities were restored without the application of a hemostatic agent; in group 2, the ca…
Effect of framework type on survival probability of implant-supported temporary crowns : an in vitro study
2020
Made available in DSpace on 2020-12-12T01:29:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: This in vitro study evaluated the effect of framework type on the survival probability of temporary implant-supported crowns and on the implant platform structure after dynamic fatigue. Material and Methods: Thirty (30) external hexagon implants (3.75 x 10 mm) were embedded in acrylic resin following the ISO-14801. Standardized temporary crowns (n=10, N=30) were manufactured in acrylic resin and divided according to the framework type: Total plastic, Plastic with CoCr base and Titanium. The crowns were installed onto the implants (20N. cm) and fatigued (100N, 2 Hz) to det…
Water diffusion and swelling stresses in ionizing radiation cured epoxy matrices
2017
Abstract In this work a DGEBF epoxy monomer was cured by electron beam radiation in the presence of an iodonium salt and the obtained system was hydrothermally aged as such and also after a thermal treatment, in order to obtain two systems having different uniformity in the cross-linking degree. On both systems, the transient stress field arising from swelling was measured and monitored by an optical Photoelastic technique and the results were commented with reference to a thermally cured epoxy system containing the same monomer and already discussed in a previous work. Beam samples with identical dimensions, obtained from the irradiated systems, have been aged at 80 °C in water, and charac…
Effect of different bleaching protocols on whitening efficiency and enamel superficial microhardness
2018
Background Tooth bleaching is a popular aesthetic treatment to modify the color of teeth. Despite the extensive literature concerning the subject, there is still no consensus regarding the application mode of the different bleaching agents and their effect on enamel. Therefore, this study evaluated the influence of different bleaching protocols on whitening efficiency and enamel superficial hardness. Material and methods Bovine enamel fragments were embedded in acrylic resin and wet-sanded to obtain a flat buccal surface. The specimens were then randomly divided into 6 groups (n=10), based on the bleaching material [HP Maxx 35% (35% hydrogen peroxide), HP Blue 35% (35% hydrogen peroxide + C…