Search results for " resolution"

showing 10 items of 1159 documents

Benign and Atypical Meningioma Metabolic Signatures by High-Resolution Magic-Angle Spinning Molecular Profiling

2008

Meningiomas are neoplasms that arise from the leptomeningeal covering of the brain and spinal cord, accounting for 15%-20% of CNS tumors. The WHO classifies meningiomas into three histological grades: benign, atypical, and anaplasic in accordance with the clinical prognosis. Atypical and anaplasic meningiomas tend to recur. Sometimes, meningiomas with histological diagnosis of benign meningioma show clinical characteristics of atypical meningioma. In this context, high-resolution magic-angle spinning (HR-MAS) spectroscopy of intact tissue from brain tumor biopsies has shown great potential as a support diagnostic tool. In this work, we show differences between benign and atypical meningioma…

AdultMalemedicine.medical_specialtyPathologyMagnetic Resonance SpectroscopyBrain tumorHigh resolutionBiologyMalignancyBiochemistryMeningiomaInternal medicineBiomarkers TumorMeningeal Neoplasmsotorhinolaryngologic diseasesmedicineHumansneoplasmsAgedAged 80 and overPrincipal Component AnalysisGene Expression ProfilingAtypical meningiomaGeneral ChemistryMiddle Agedmedicine.diseaseSpinal cordnervous system diseasesGene expression profilingEndocrinologymedicine.anatomical_structureBenign MeningiomaFemaleMeningiomaJournal of Proteome Research
researchProduct

Ex vivo high resolution magic angle spinning metabolic profiles describe intratumoral histopathological tissue properties in adult human gliomas.

2010

In gliomas one can observe distinct histopathological tissue properties, such as viable tumor cells, necrotic tissue or regions where the tumor infiltrates normal brain. A first screening between the different intratumoral histopathological tissue properties would greatly assist in correctly diagnosing and prognosing gliomas. The potential of ex vivo high resolution magic angle spinning spectroscopy in characterizing these properties is analyzed and the biochemical differences between necrosis, high cellularity and border tumor regions in adult human gliomas are investigated. Statistical studies applied on sets of metabolite concentrations and metabolite ratios extracted from 52 high resolu…

AdultPathologymedicine.medical_specialtyMagnetic Resonance SpectroscopyNecrosisBrain NeoplasmsReference tissueChemistryBiopsyMetaboliteHigh resolutionGliomaIn Vitro TechniquesNecrotic tissueMalignancy gradechemistry.chemical_compoundMagic angle spinningmedicineHumansRadiology Nuclear Medicine and imagingmedicine.symptomEx vivo
researchProduct

Improved land surface emissivities over agricultural areas using ASTER NDVI

2006

Abstract Land surface emissivity retrieval over agricultural regions is important for energy balance estimations, land cover assessment and other related environmental studies. The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) produces images of sufficient spatial resolution (from 15 m to 90 m) to be of use in agricultural studies, in which fields of crops are too small to be well-resolved by low resolution sensors. The ASTER project generates land surface emissivity images as a Standard Product (AST05) using the Temperature/Emissivity Separation (TES) algorithm. However, the TES algorithm is prone to scaling errors in estimating emissivities for surfaces with low s…

Advanced Spaceborne Thermal Emission and Reflection RadiometerRadiometerMean squared errorAtmospheric correctionEmissivitySoil ScienceEnvironmental scienceGeologyLand coverComputers in Earth SciencesImage resolutionNormalized Difference Vegetation IndexRemote sensingRemote Sensing of Environment
researchProduct

Study of Temperature Heterogeneities at Sub-Kilometric Scales and Influence on Surface–Atmosphere Energy Interactions

2019

The retrieval of land surface temperature (LST) from remote sensing techniques has been studied and validated during the past 40 years, leading to important improvements. Accurate LST values are currently obtained through measurements using medium resolution thermal infrared (TIR) sensors. However, the most recent review reports demonstrated that the future TIR LST products need to obtain reliable temperature values at a high spatial resolution (100 m or higher) to study temperature variations between different elements in a heterogeneous kilometric area. The launch of high-resolution TIR sensors in the near future requires studies of the temporal evolution and spatial heterogeneities of th…

Advection0211 other engineering and technologiesTerrain02 engineering and technologyTemperature measurementAtmosphereSea surface temperatureThermalGeneral Earth and Planetary SciencesEnvironmental scienceSatelliteElectrical and Electronic EngineeringImage resolution021101 geological & geomatics engineeringRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct

Cardiac Micro–Computed Tomography Imaging of the Aging Coronary Vasculature

2012

Background— Alterations at the level of the coronary circulation with aging may play an important role in the evolution of age-associated changes in left ventricular (LV) fibrosis and function. However these age-associated changes in the coronary vasculature remain poorly defined primarily due to the lack of high resolution imaging technologies. The current study was designed to utilize cardiac micro–computed tomography (micro-CT) technology as a novel imaging strategy, to define the 3-dimensional coronary circulation in the young and aged heart and its relationship to LV fibrosis and function. Methods and Results— Young (2 months old; n=10) and aged (20 months old; n=10) Fischer rats unde…

Agingmedicine.medical_specialtyX-ray microtomographyBlood PressureArticleVentricular Dysfunction LeftCoronary circulationImaging Three-DimensionalFibrosisCoronary CirculationInternal medicineLv dysfunctionAnimalsMedicineRadiology Nuclear Medicine and imagingbusiness.industryMicro computed tomographyCoronary vasculatureImaging studyX-Ray Microtomographymedicine.diseaseFibrosisSettore MED/11 - Malattie Dell'Apparato CardiovascolareRats Inbred F344Ratsmedicine.anatomical_structureBlood pressureEchocardiographyHigh resolution imaging techinques.Linear ModelsCardiologyCardiology and Cardiovascular MedicinebusinessCirculation: Cardiovascular Imaging
researchProduct

Gain lifetime measurement of a Ni-like Ag soft X-ray laser

2012

International audience; Experimental results of a two-stage Ni-like Ag soft X-ray laser operated in a seed-amplifier configuration are presented. Both targets were pumped applying the double-pulse grazing incidence technique with intrinsic travelling wave excitation. The injection of the seed X-ray laser into the amplifier target was realized by a spherical mirror. The results show amplification of the seed X-ray laser and allow for a direct measurement of the gain lifetime. The experimental configuration is suitable for providing valuable input for computational simulations. (C) 2012 Optical Society of America

Amplified spontaneous emissionCODEPhysics::OpticsCurved mirrorBEAM01 natural scienceslaw.inventionCOHERENT010309 opticsLaser linewidthOptics[PHYS.PHYS.PHYS-PLASM-PH]Physics [physics]/Physics [physics]/Plasma Physics [physics.plasm-ph]law0103 physical sciencesSpontaneous emission010306 general physicsPhysics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryAmplifierLaserAtomic and Molecular Physics and OpticsTemporal resolutionOptoelectronicsbusinessExcitationOptics Express
researchProduct

Multivariate optimization approach for chiral resolution of drugs using human serum albumin in affinity electrokinetic chromatography-partial filling…

2005

The enantiomeric resolution of chiral compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer, protein and compound solutions) and protein solution plug length. In this paper multivariate optimization approaches for chiral separation of four basic drugs (alprenolol, oxprenolol, promethazine and propranolol) using HSA as chiral selector in AEKC-partial filling technique are studied. The experimental conditions to achieve maximum resolution are optimized using the Box-Behnken experimental design. Partial least squares a…

AnalyteResolution (mass spectrometry)Clinical BiochemistryAnalytical chemistryBiochemistryPromethazineChromatography AffinityAnalytical ChemistryElectrokinetic phenomenaPartial least squares regressionmedicineHumansAminesAlprenololSerum AlbuminChromatographyChemistryElectrophoresis CapillaryOxprenololStereoisomerismHuman serum albuminPropranololChiral resolutionElectrophoresisPharmaceutical PreparationsMultivariate AnalysisEnantiomerHydrophobic and Hydrophilic Interactionsmedicine.drugElectrophoresis
researchProduct

Stimulated Raman and Cars Spectroscopy of ν1 and 2ν2 (A1) Bands of 12CF4

1994

Two experimental coherent Raman techniques, stimulated Raman and coherent anti-Stokes Raman spectroscopy (CARS), were employed to study the Raman spectrum of CF 4 in the 900 cm −1 region. The stimulated Raman and CARS spectra of the ν 1 band of CF 4 were recorded at high resolution. The analysis of these spectra enabled some spectroscopic constants of this band to be refined and higher order constants to be determined for the first time. The first high-resolution CARS spectrum of the 2ν 2 (A 1 ) harmonic band is also presented. The rotational transitions of this band up to J = 40 were assigned and the first set of spectroscopic constants for this sub-level were determined. These results imp…

Analytical chemistryHigh resolutionCF4 LASER02 engineering and technology01 natural sciencesQ-BRANCHSpectral lineREGIONABSORPTION-SPECTROSCOPYsymbols.namesake0103 physical sciencesVibrational bandsSPECTRAGeneral Materials ScienceStimulated ramanCoherent anti-Stokes Raman spectroscopyStimulated emissionPOTENTIAL FUNCTIONRADIOFREQUENCY DOUBLE-RESONANCESpectroscopySpectroscopy010304 chemical physicsMOLECULAR LASERSChemistry021001 nanoscience & nanotechnologyRESOLUTION INFRARED-SPECTROSCOPYsymbols0210 nano-technologyRaman spectroscopyDOUBLE-RESONANCE SPECTROSCOPY
researchProduct

High-resolution stimulated Raman spectroscopy and analysis of the ν 1 band of osmium tetroxide

2012

D.B.P. and R.Z.M. acknowledge the financial support of the Ministry of Science and Innovation through research grant no. FIS2009-08069.

Analytical chemistryHigh resolutionsymbols.namesakechemistry.chemical_compoundOsmium tetroxidechemistrysymbolsGeneral Materials ScienceChristian ministryIsotopologueStimulated ramanRaman spectroscopySpectroscopySpectroscopyJournal of Raman Spectroscopy
researchProduct

A method for the surface reflectance retrieval from PROBA/CHRIS data over land: application to ESA SPARC campaigns

2005

The Compact High Resolution Imaging Spectrometer (CHRIS) onboard the Project for On-Board Autonomy (PROBA) platform system provides the first high spatial resolution hyper-spectral/multiangular remote sensing data from a satellite system, what represents a new source of information for Earth Observation purposes. A fully consistent radiative transfer approach is always preferred when dealing with the retrieval of surface reflectance from hyperspectral/multiangular data. However, due to the reported calibration anomalies for CHRIS data, a direct atmospheric correction based on physical radiative transfer modeling is not possible, and the method must somehow compensate for such calibration pr…

Ancillary dataEarth observationSpectrometerAtmospheric correctionRadiative transferCalibrationGeneral Earth and Planetary SciencesHyperspectral imagingEnvironmental science550 - Earth sciencesElectrical and Electronic EngineeringImage resolutionRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct