Search results for " resolution"
showing 10 items of 1159 documents
Benign and Atypical Meningioma Metabolic Signatures by High-Resolution Magic-Angle Spinning Molecular Profiling
2008
Meningiomas are neoplasms that arise from the leptomeningeal covering of the brain and spinal cord, accounting for 15%-20% of CNS tumors. The WHO classifies meningiomas into three histological grades: benign, atypical, and anaplasic in accordance with the clinical prognosis. Atypical and anaplasic meningiomas tend to recur. Sometimes, meningiomas with histological diagnosis of benign meningioma show clinical characteristics of atypical meningioma. In this context, high-resolution magic-angle spinning (HR-MAS) spectroscopy of intact tissue from brain tumor biopsies has shown great potential as a support diagnostic tool. In this work, we show differences between benign and atypical meningioma…
Ex vivo high resolution magic angle spinning metabolic profiles describe intratumoral histopathological tissue properties in adult human gliomas.
2010
In gliomas one can observe distinct histopathological tissue properties, such as viable tumor cells, necrotic tissue or regions where the tumor infiltrates normal brain. A first screening between the different intratumoral histopathological tissue properties would greatly assist in correctly diagnosing and prognosing gliomas. The potential of ex vivo high resolution magic angle spinning spectroscopy in characterizing these properties is analyzed and the biochemical differences between necrosis, high cellularity and border tumor regions in adult human gliomas are investigated. Statistical studies applied on sets of metabolite concentrations and metabolite ratios extracted from 52 high resolu…
Improved land surface emissivities over agricultural areas using ASTER NDVI
2006
Abstract Land surface emissivity retrieval over agricultural regions is important for energy balance estimations, land cover assessment and other related environmental studies. The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) produces images of sufficient spatial resolution (from 15 m to 90 m) to be of use in agricultural studies, in which fields of crops are too small to be well-resolved by low resolution sensors. The ASTER project generates land surface emissivity images as a Standard Product (AST05) using the Temperature/Emissivity Separation (TES) algorithm. However, the TES algorithm is prone to scaling errors in estimating emissivities for surfaces with low s…
Study of Temperature Heterogeneities at Sub-Kilometric Scales and Influence on Surface–Atmosphere Energy Interactions
2019
The retrieval of land surface temperature (LST) from remote sensing techniques has been studied and validated during the past 40 years, leading to important improvements. Accurate LST values are currently obtained through measurements using medium resolution thermal infrared (TIR) sensors. However, the most recent review reports demonstrated that the future TIR LST products need to obtain reliable temperature values at a high spatial resolution (100 m or higher) to study temperature variations between different elements in a heterogeneous kilometric area. The launch of high-resolution TIR sensors in the near future requires studies of the temporal evolution and spatial heterogeneities of th…
Cardiac Micro–Computed Tomography Imaging of the Aging Coronary Vasculature
2012
Background— Alterations at the level of the coronary circulation with aging may play an important role in the evolution of age-associated changes in left ventricular (LV) fibrosis and function. However these age-associated changes in the coronary vasculature remain poorly defined primarily due to the lack of high resolution imaging technologies. The current study was designed to utilize cardiac micro–computed tomography (micro-CT) technology as a novel imaging strategy, to define the 3-dimensional coronary circulation in the young and aged heart and its relationship to LV fibrosis and function. Methods and Results— Young (2 months old; n=10) and aged (20 months old; n=10) Fischer rats unde…
Gain lifetime measurement of a Ni-like Ag soft X-ray laser
2012
International audience; Experimental results of a two-stage Ni-like Ag soft X-ray laser operated in a seed-amplifier configuration are presented. Both targets were pumped applying the double-pulse grazing incidence technique with intrinsic travelling wave excitation. The injection of the seed X-ray laser into the amplifier target was realized by a spherical mirror. The results show amplification of the seed X-ray laser and allow for a direct measurement of the gain lifetime. The experimental configuration is suitable for providing valuable input for computational simulations. (C) 2012 Optical Society of America
Multivariate optimization approach for chiral resolution of drugs using human serum albumin in affinity electrokinetic chromatography-partial filling…
2005
The enantiomeric resolution of chiral compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer, protein and compound solutions) and protein solution plug length. In this paper multivariate optimization approaches for chiral separation of four basic drugs (alprenolol, oxprenolol, promethazine and propranolol) using HSA as chiral selector in AEKC-partial filling technique are studied. The experimental conditions to achieve maximum resolution are optimized using the Box-Behnken experimental design. Partial least squares a…
Stimulated Raman and Cars Spectroscopy of ν1 and 2ν2 (A1) Bands of 12CF4
1994
Two experimental coherent Raman techniques, stimulated Raman and coherent anti-Stokes Raman spectroscopy (CARS), were employed to study the Raman spectrum of CF 4 in the 900 cm −1 region. The stimulated Raman and CARS spectra of the ν 1 band of CF 4 were recorded at high resolution. The analysis of these spectra enabled some spectroscopic constants of this band to be refined and higher order constants to be determined for the first time. The first high-resolution CARS spectrum of the 2ν 2 (A 1 ) harmonic band is also presented. The rotational transitions of this band up to J = 40 were assigned and the first set of spectroscopic constants for this sub-level were determined. These results imp…
High-resolution stimulated Raman spectroscopy and analysis of the ν 1 band of osmium tetroxide
2012
D.B.P. and R.Z.M. acknowledge the financial support of the Ministry of Science and Innovation through research grant no. FIS2009-08069.
A method for the surface reflectance retrieval from PROBA/CHRIS data over land: application to ESA SPARC campaigns
2005
The Compact High Resolution Imaging Spectrometer (CHRIS) onboard the Project for On-Board Autonomy (PROBA) platform system provides the first high spatial resolution hyper-spectral/multiangular remote sensing data from a satellite system, what represents a new source of information for Earth Observation purposes. A fully consistent radiative transfer approach is always preferred when dealing with the retrieval of surface reflectance from hyperspectral/multiangular data. However, due to the reported calibration anomalies for CHRIS data, a direct atmospheric correction based on physical radiative transfer modeling is not possible, and the method must somehow compensate for such calibration pr…