Search results for " solution"

showing 10 items of 3084 documents

A new ionic liquid dimethyldinonylammonium bromide as a flow modifier for the simultaneous determination of eight carboxylates by capillary electroph…

2005

Two new methods of capillary zone electrophoresis based on aqueous phosphate running buffers with UV spectrophotometric detection were developed and optimized for the determination of eight carboxylates as copper complexes. Metalcomplexes are negatively charged, so measurements were made as anion analyses with flow reversal in the capillary. Two flow modifiers were used: a common tetradecyltrimethylammonium bromide (TTAB) and a new ionic liquid dimethyldinonylammonium bromide (DMDNAB). The methods were compared to each other. Better separation was achieved with DMDNAB as the flow modifier. Method development was done using a fused silica capillary (61 cm x 50 microm i.d.). Optimization was …

ChromatographyAqueous solutionmedicine.diagnostic_testCapillary actionOrganic ChemistryAnalytical chemistryCarboxylic Acidschemistry.chemical_elementElectrophoresis CapillaryGeneral MedicineBiochemistryCopperTrimethyl Ammonium CompoundsAnalytical ChemistryQuaternary Ammonium Compoundschemistry.chemical_compoundElectrophoresisCapillary electrophoresischemistrySpectrophotometryIonic liquidmedicineSpectrophotometry UltravioletCarboxylateWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Chromatographic Efficiency in Micellar Liquid Chromatography: Should it Be Still a Topic of Concern?

2013

Micellar liquid chromatography (MLC) was first proposed as an attractive alternative to avoid the use of organic solvents. It was soon apparent that pure micellar solutions yield poor efficiencies. This problem was remediated by the addition of a small amount of an organic solvent. However, the general opinion of the poor peak shape has prevailed as a handicap for MLC, in spite of the fact that the hybrid mode often offers similar or even improved efficiencies (for basic compounds) relative to that attained in the hydro-organic mode. Only the efficiencies for apolar non-ionizable compounds are still clearly inferior. This work describes the type of interactions and polarity changes with org…

ChromatographyChemistryHydrophilic interaction chromatographyAnalytical chemistryFiltration and SeparationSilanol effect suppressionAnalytical ChemistryAdsorptionHybrid mobile phasesPulmonary surfactantMicellar liquid chromatographyYield (chemistry)Mass transferBand broadeningMicellar solutionsMass transferenceWettingMicellar liquid chromatographyStationary phase architecture and wettingSeparation & Purification Reviews
researchProduct

Determination of Anticonvulsant Drugs in Pharmaceutical Preparations by Micellar Liquid Chromatography

2004

A micellar liquid chromatographic method for quality control of pharmaceutical preparations (capsules, pills, tablets, injections, drops, and suppositories) containing the anticonvulsant drugs acetazolamide, carbamacepine, chlordiazepoxide, diazepam, ethosuximide, phenytoin, phenobarbital, and zopiclone has been developed. This methodology involves the use of micellar solutions of cetyltrimethylammonium bromide (CTAB) as mobile phases and UV detection. The proposed approach is rapid and reproducible. Sample preparation only requires dissolution with micellar solvent and adequate dilution with the mobile phase before injection into the chromatographic system.

ChromatographyChemistrymedicine.medical_treatmentClinical Biochemistrytechnology industry and agriculturePharmaceutical ScienceBiochemistryDosage formAnalytical ChemistryChlordiazepoxideSolventEthosuximideAnticonvulsantMicellar liquid chromatographyMicellar solutionsmedicinelipids (amino acids peptides and proteins)Sample preparationmedicine.drugJournal of Liquid Chromatography & Related Technologies
researchProduct

Alkaline haematin D-575, a new tool for the determination of haemoglobin as an alternative to the cyanhaemiglobin method. I. description of the method

1984

A new method for the rapid and accurate measurement of haemoglobin has been developed as an alternative to the conventional cyanhaemiglobin method. This method is based on the conversion of all haeme, haemoglobin, and haemiglobin species into a stable end product by an alkaline solution of a non-ionic detergent ('AHD reagent'). The reaction product, designated as alkaline haematin D-575, is extremely stable and shows a characteristic absorption peak at 575 nm. As compared to the cyanhaemiglobin method, the determination of haemoglobin by alkaline haematin D-575 offers several advantages such as (1) extreme stability of the AHD reagent and the conversion product, (2) decreased conversion tim…

ChromatographyHemeproteinOctoxynolChemistryStereochemistrySmokingBiochemistry (medical)Clinical BiochemistryHemeGeneral MedicineHydrogen-Ion ConcentrationBiochemistryHaematinPolyethylene GlycolsReaction productPhotometryHemoglobinschemistry.chemical_compoundBasic solutionReagentHeminHumansHemoglobinClinica Chimica Acta
researchProduct

Ion-exchange voltammetry at a surfactant-doped electrode: model of mass transfer kinetics to an anionic surface-charged electrode and its application…

2000

cited By 10; International audience; A theoretical model of mass transfer kinetics was developed for investigating the accumulation of cationic compounds at an anionic surfactant-doped screen-printed electrode. It was extended to an enzyme-generated cationic product for the indirect determination of alkaline phosphatase (AP). The model takes into account the analyte depletion, the kinetics of the ion-exchange reaction-diffusion and the kinetics of the enzymatic reaction. The relationship between the ion-exchange voltammetric anodic peak current and the enzyme incubation/accumulation time for a given concentration of AP was established and the validity of the theoretical model was verified e…

ChromatographyIon exchangeGeneral Chemical EngineeringKineticsInorganic chemistryCationic polymerizationSubstrate (chemistry)02 engineering and technologyBuffer solution010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical ChemistryElectrochemical gas sensorchemistry.chemical_compoundchemistryElectrodeElectrochemistry[CHIM]Chemical Sciences0210 nano-technologyVoltammetry
researchProduct

Volumes and compressibilities of pentanol in aqueous alkyltrimethylammonium bromide solutions at different temperatures

1990

Speed of sound and density properties of ternary water-tetradecyltrimethylammonium bromide-pentanol system at 15, 25 and 35°C and of water-hexadecyltrimethylammonium bromide-pentanol system at 25, 35 and 45°C were measured at fixed alcohol concentration as a function of surfactant concentration. The apparent molar volumes Vϕ,R and isentropic compressibilities Kϕ,RS of pentanol in micellar solutions as a function of the surfactant concentration show irregular behavior which depends on the alkyl chain length of the surfactant and tends to disappear with increasing temperature. These anomalies are ascribed to micellar transitions. For both surfactants at high concentrations, Vϕ,R decrease and …

ChromatographyIsentropic processChemistryDistribution constanttechnology industry and agricultureBiophysicsThermodynamicsPrimary alcoholBiochemistryApparent molar propertyMolar volumePulmonary surfactantPhase (matter)Micellar solutionslipids (amino acids peptides and proteins)Physical and Theoretical ChemistryMolecular BiologyJournal of Solution Chemistry
researchProduct

Development of predictive retention-activity relationship models of non-steroidal anti-inflammatory drugs by micellar liquid chromatography: comparis…

2000

The predictive and interpretative capability of quantitative chromatographic retention-biological activity models is supported by the fact that under adequate experimental conditions the solute partitioning into chromatographic system can emulate the solute partitioning into lipid bilayers of biological membranes, which is the basis for drug and metabolite uptake, passive transport across membranes and bioaccumulation. The use of micellar solutions of Brij35 as mobile phases in reversed-phase liquid chromatography has proven to be valid to predict some biological activities of different kinds of drugs. In this study, quantitative retention-activity relationship (QRAR) models to describe som…

ChromatographyPassive transportMetaboliteAnti-Inflammatory Agents Non-SteroidalSynthetic membraneBiological membraneMembranes ArtificialGeneral Chemistrychemistry.chemical_compoundStructure-Activity RelationshipMembranechemistryMicellar liquid chromatographyPredictive Value of TestsMicellar solutionsLipid bilayerChromatography LiquidJournal of chromatography. B, Biomedical sciences and applications
researchProduct

Quantitative retention- and migration-toxicity relationships of phenoxy acid herbicides in micellar liquid chromatography and micellar electrokinetic…

2001

Abstract The need to obtain a tool for estimation of toxicity parameters for chemicals supports, the postulation of predictive models as an alternative to conventional classical assays. The use of micellar solutions of Brij35 as mobile phases in reversed phase liquid chromatography has proven to be valid in predicting some biological activities of different kinds of drugs. In this paper, the correlations between retention of phenoxy acids using different concentrations of Brij35 as micellar mobile phase in micellar liquid chromatography (MLC) and migration in micellar electrokinetic chromatography (MEKC) with several toxicity parameters are studied. Adequate correlations retention- and migr…

ChromatographybiologyChemistrymacromolecular substancesReversed-phase chromatographybiology.organism_classificationBiochemistryDaphniaMicellar electrokinetic chromatographyAnalytical ChemistryAquatic toxicologyMicellar liquid chromatographyMicellar solutionsEnvironmental ChemistryOrganic chemistryQuantitative analysis (chemistry)Chronic toxicitySpectroscopyAnalytica Chimica Acta
researchProduct

Physicochemical stability of carfilzomib (Kyprolis®) containing solutions in glass vials, ready-to-administer plastic syringes and infusion bags over…

2017

Centralized aseptic preparation of ready-to-administer carfilzomib containing parenteral solutions in plastic syringes and polyolefine (PO) infusion bags needs profound knowledge about the physicochemical stability in order to determine the beyond-use-date of the preparations. Therefore, the purpose of this study was to determine the physicochemical stability of carfilzomib solution marketed as Kyprolis® powder for solution for infusion. Reconstituted solutions and ready-to-administer preparations of Kyprolis® stored under refrigeration (2–8℃) or at room temperature (25℃) were analyzed at predetermined intervals over a maximum storage period of 28 days. Chemical stability of carfilzomib wa…

Chromatographybusiness.industryInfusion solutionPh measurementCarfilzomibVial03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOncologychemistry030220 oncology & carcinogenesisMedicinePharmacology (medical)Aseptic processingbusinessParenteral solutions030215 immunologyJournal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners
researchProduct

Molecular heterogeneity of the hemocyanin isolated from the king crabParalithodes camtschaticae

2000

Native Paralithodes camtschaticae hemocyanin is found as a mixture of dodecamers (24S; 80%) and hexamers (16S; 20%). Removal of Ca2+ ions by dialysis against EDTA-containing buffer solution at neutral pH induces complete dissociation of the 24S form into the 16S form. Under these conditions, a further increase in pH to 9.2 produces complete dissociation of the hexamers into monomers (5S). In both cases, the dissociation process is reversible. The dodecamer (24S) is composed of two different hexamers which can be discriminated only by ion-exchange chromatography in the presence of Ca2+ ions. At alkaline pH and in the presence of EDTA, two major monomeric fractions can be separated by ion-exc…

Chromatographymedicine.medical_treatmentHemocyaninBohr effectBuffer solutionBiochemistryDissociation (chemistry)Crystallographychemistry.chemical_compoundDodecameric proteinMonomerchemistrymedicineProtein quaternary structureOxygen bindingEuropean Journal of Biochemistry
researchProduct