Search results for " stenosi"

showing 10 items of 306 documents

Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation

2020

The severity of aortic stenosis (AS) has traditionally been graded by measuring hemodynamic parameters of transvalvular pressure gradient, ejection jet velocity, or estimating valve orifice area. Recent research has highlighted limitations of these criteria at effectively grading AS in presence of left ventricle (LV) dysfunction. We hypothesized that simulations coupling the aorta and LV could provide meaningful insight into myocardial biomechanical derangements that accompany AS. A realistic finite element model of the human heart with a coupled lumped-parameter circulatory system was used to simulate AS. Finite element analysis was performed with Abaqus FEA. An anisotropic hyperelastic mo…

medicine.medical_specialtyPhysiology0206 medical engineeringfinite element methodHemodynamics02 engineering and technology030204 cardiovascular system & hematologylcsh:PhysiologyStress (mechanics)03 medical and health sciences0302 clinical medicinemedicine.arteryInternal medicinePhysiology (medical)medicinemyofiber stressMyocyteAortalcsh:QP1-981business.industryAortic stenosisBiomechanicsrealistic simulationSettore ING-IND/34 - Bioingegneria Industrialemedicine.disease020601 biomedical engineeringStenosismedicine.anatomical_structureVentricleCirculatory systemCardiologyventricular functionventricle-aortic couplingbusiness
researchProduct

Heart involvement in rheumatoid arthritis: systematic review and meta-analysis.

2013

Abstract Objective The aim of our study was to conduct a systematic review with meta-analysis of the current case–control studies about the valvular and pericardial involvement in patients with Rheumatoid Arthritis (RA), asymptomatic for cardiovascular diseases. Methods Case–control studies were identified by searching PubMed (1975–2010) and the Cochrane Central Register of Controlled Trials (CENTRAL) (1975–2010). Participants were adult patients with RA asymptomatic for cardiovascular diseases, and the outcome measure was the presence of cardiac involvement. Results Quantitative synthesis included 10 relevant studies out of 2326 bibliographic citations that had been found. RA resulted sign…

medicine.medical_specialtySettore MED/09 - Medicina InternaHeart Valve DiseasesPericardial effusionAsymptomaticArthritis RheumatoidInternal medicineMitral valvemedicineMitral valve prolapseHumansbusiness.industrymedicine.diseaseRheumatoid Arthritis Systematic review Meta-analysis Echocardiography assessment Pericardial disease Cardiac valvular calcificationSettore MED/45 - Scienze Infermieristiche Generali Cliniche E Pediatrichemedicine.anatomical_structureCardiovascular DiseasesEchocardiographyAortic valve stenosisRheumatoid arthritisMeta-analysisCase-Control StudiesCardiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessCalcificationInternational journal of cardiology
researchProduct

Detection of benign hilar bile duct stenoses – A retrospective analysis in 250 patients with suspicion of Klatskin tumour

2016

Introduction The aim of this study was to identify clinical, laboratory and radiological parameters to distinguish benign from malignant stenoses of the proximal bile duct. Methods Between 1997 and 2011, 250 patients were referred to our clinic with hilar bile duct stenoses suspicious for Klatskin tumour. Medical histories, clinical data, pre-interventional laboratory tests, imaging findings, as well as therapeutic approach and patient outcome were compared to final histological results. All data were retrieved from our prospectively maintained database and analysed retrospectively. Results We found benign bile duct lesions in 34 patients (13.6%). Among the entire study population, uni- and…

medicine.medical_specialtySurgical procedureBile ductbusiness.industryGeneral MedicineKlatskin tumourMimicking lesions03 medical and health sciences0302 clinical medicinemedicine.anatomical_structure030220 oncology & carcinogenesisRadiological weaponmedicineRetrospective analysisBenign hilar stenosis030211 gastroenterology & hepatologySurgeryRadiologyDiagnosticbusinessOriginal ResearchAnnals of Medicine and Surgery
researchProduct

Ultrasound-guided spinal fracture repositioning

1998

The management of narrowing spinal fragments in the operative treatment of spinal fractures remains an open question, in particular when the procedure is performed by a posterior approach. This article describes the use of intraoperative ultrasonography during spinal surgery. From 1990 to 1997, 116 spinal fractures were treated operatively at our clinic. Stabilization of the spine was achieved with the AO fixateur interne and the AO USS, respectively (Synthes, D-79224, Umkirch, Germany). For 60 cases who had a fractured posterior vertebral surface dislocated into the spinal canal, we used intraoperative ultrasonography to monitor the repositioning of the narrowing fragments. The patients un…

medicine.medical_specialtyThoracic VertebraePosterior approachIntraoperative ultrasoundFracture Fixation InternalIntraoperative PeriodSpinal StenosisSpinal fractureHumansMedicineSpinal canalRachisRetrospective StudiesUltrasonography Doppler DuplexLumbar VertebraeSpinalisbusiness.industryReproducibility of Resultsmedicine.diseaseUltrasound guidedmedicine.anatomical_structureSpinal FracturesSurgeryRadiologyTomography X-Ray ComputedbusinessSpinal CanalAbdominal surgerySurgical Endoscopy
researchProduct

Comparison of Percutaneous Coronary Intervention (With Drug-Eluting Stents) Versus Coronary Artery Bypass Grafting in Women With Severe Narrowing of …

2014

Women typically present with coronary artery disease later than men with more unfavorable clinical and anatomic characteristics. It is unknown whether differences exist in women undergoing treatment for unprotected left main coronary artery (ULMCA) disease. Our aim was to evaluate long-term clinical outcomes in women treated with percutaneous coronary intervention (PCI) with drug-eluting stents versus coronary artery bypass grafting (CABG). All consecutive women from the Drug-Eluting stent for LefT main coronary Artery disease registry with ULMCA disease were analyzed. A propensity matching was performed to adjust for baseline differences. In total, 817 women were included: 489 (59.8%) unde…

medicine.medical_specialtyTime Factorsmedicine.medical_treatmentCoronary AngiographySeverity of Illness IndexCoronary artery diseasePercutaneous Coronary InterventionRisk FactorsInternal medicinemedicineHumansMyocardial infarctionRegistriesCoronary Artery BypassPropensity ScoreAgedRetrospective Studiesbusiness.industryCoronary StenosisPercutaneous coronary interventionStentDrug-Eluting StentsOdds ratiomedicine.diseaseCoronary VesselsSurgerymedicine.anatomical_structureTreatment OutcomeDrug-eluting stentConventional PCICardiologyFemaleCardiology and Cardiovascular MedicinebusinessArteryFollow-Up Studies
researchProduct

Coronary stent implantation in acute vessel closure 48 hours after an unsatisfactory coronary angioplasty

1990

We report the implantation of a balloon-expandable stent in a patient with acute vessel closure in the state of evolving myocardial infarction following 48 hr after unsatisfactory coronary angioplasty. The stent was implanted after successful recanalization of an occluded left anterior descending artery, with repeated unsatisfactory results of balloon angioplasty. Adjunct thrombolytic therapy was contraindicated. No residual stenosis was documented in immediate control angiograms, or after 24 hr, 3 weeks, and 4 months.

medicine.medical_specialtyTime Factorsmedicine.medical_treatmentCoronary DiseaseCoronary AngiographyBalloonAngioplastyInternal medicineCoronary stentmedicineHumansAngina Unstablecardiovascular diseasesMyocardial infarctionAngioplasty Balloon Coronarybusiness.industryStentResidual stenosisMiddle Agedmedicine.diseaseCoronary VesselsSurgerymedicine.anatomical_structureCardiologyStentsCardiology and Cardiovascular MedicineComplicationbusinessArteryCatheterization and Cardiovascular Diagnosis
researchProduct

Transverse Small Skin Incision for Carotid Endarterectomy

2015

The purpose of this report is to determine the feasibility of short transverse skin incision (STI4 cm) for eversion (EEA) and patch (PEA) endarterectomy with or without shunt by comparing it with the outcomes after long transverse skin incision (LTI 4-8 cm).Of 164 elective consecutive patients (71 ± 2.73% symptomatic) operated at one institution over 24 months, 81 were treated with STI, while 83 patients received LTI. The LTI and STI groups did not differ in terms of age, symptoms, or risk factors. EEA or PEA under locoregional (LRA) or general (GA) anesthesia were performed.STI was associated with shorter operation times (75.19 ± 15.33 vs. 94.87 ± 41 and 99.4 ± 27.36 vs. 132.66 ± 51.32, re…

medicine.medical_specialtyTime Factorsmedicine.medical_treatmentDermatologic Surgical ProceduresOperative TimeMedizinCarotid endarterectomyAnesthesia Generalurologic and male genital diseasesSeverity of Illness IndexCicatrixGermanyHumansMedicineCarotid StenosisParesthesiaEndarterectomy CarotidSkin incisionbusiness.industryGeneral Medicinefemale genital diseases and pregnancy complicationsSurgeryTreatment OutcomeFeasibility StudiesSurgeryCardiology and Cardiovascular MedicineComplicationbusinessAnesthesia LocalAnnals of Vascular Surgery
researchProduct

Successful transcatheter aortic valve-in-valve implantation in a patient having a chronic type A aortic dissection

2017

medicine.medical_specialtyTranscatheter aortic030204 cardiovascular system & hematologyTranscatheter Aortic Valve Replacement03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineInternal medicineHumansMedicineAgedAortic dissectionAortic Aneurysm Thoracicbusiness.industryAngiographyAortic Valve Stenosis030229 sport sciencesmedicine.diseaseEchocardiography DopplerValve in valveAortic ValveHeart Valve ProsthesisChronic DiseaseCardiologyFemaleTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessEuropean Heart Journal
researchProduct

Rationale and design of the Dapagliflozin after Transcatheter Aortic Valve Implantation (DapaTAVI) randomized trial.

2021

Aims Despite aortic stenosis (AS) relief, patients undergoing transcatheter aortic valve implantation (TAVI) are at increased risk of developing heart failure (HF) within first months of intervention. Sodium-glucose co-transporter 2 (SGLT-2) inhibitors have been shown to reduce the risk of HF hospitalization in individuals with diabetes mellitus (DM), reduced left ventricular ejection fraction (LVEF) and chronic kidney disease (CKD). However, the effect of SGLT-2 inhibitors on outcomes after TAVI is unknown. The Dapagliflozin after Transcatheter Aortic Valve Implantation (DapaTAVI) trial is designed to assess the clinical benefit and safety of the SGLT-2 inhibitor dapagliflozin in patients …

medicine.medical_specialtyTranscatheter aorticVentricular Function Leftlaw.inventionTranscatheter Aortic Valve Replacementchemistry.chemical_compoundRandomized controlled trialGlucosideslawInternal medicineDiabetes mellitusmedicineHumansProspective StudiesDapagliflozinBenzhydryl CompoundsHeart FailureEjection fractionbusiness.industryStroke VolumeAortic Valve Stenosismedicine.diseaseStenosisTreatment OutcomechemistryHeart failureAortic ValveCardiologyCardiology and Cardiovascular MedicinebusinessKidney diseaseEuropean journal of heart failureReferences
researchProduct

Factors Correlating with Restenosis after PTCA

1991

Since its introduction in 1977 [7, 8], PTCA has been widely used in patients with coronary artery disease. Restenosis with recurrence of angina remains the major problem, limiting the long-term success after PTCA. Reported restenosis rates vary from 17% to 47% [9–19, 22–26]. In larger series [12, 15, 26] a restenosis rate of about 30% was constantly found, irrespective of the definition of restenosis in use.

medicine.medical_specialtyUnstable anginabusiness.industryLimitingResidual stenosismedicine.diseaseAnginaCoronary artery diseaseRestenosisInternal medicinemedicineCardiologyIn patientbusiness
researchProduct