Search results for " ultrasonic"

showing 10 items of 344 documents

Laser-ultrasonics: a non-contact method to link the acoustic attenuation to metal damping properties up to the melting point

2004

The objective of this work is to describe the viscoelastic behavior of metals up to their melting temperature by measuring the velocity and the attenuation of ultrasonics waves. For that purpose, a technique called laser-ultrasonics has been optimized for the high temperature domain and the solid to liquid transition. This paper is especially applied to the viscoelastic characterization of tin, from room temperature up to the melting point.

Laser ultrasonicsWork (thermodynamics)Materials scienceMechanical EngineeringAttenuationchemistry.chemical_elementMineralogyCondensed Matter PhysicsViscoelasticityCharacterization (materials science)Condensed Matter::Soft Condensed MatterchemistryMechanics of MaterialsMelting pointGeneral Materials ScienceComposite materialTinAcoustic attenuationMaterials Science and Engineering: A
researchProduct

Effects of high power ultrasound treatments on the phenolic, chromatic and aroma composition of young and aged red wine

2019

Abstract In this study, the effects of both ultrasonic bath and probe treatments on the phenolic, chromatic and aroma composition of young red wine Cabernet Sauvignon were studied and modeled by artificial neural networks (ANNs). Moreover, the effect of high power ultrasound (HPU) along with antioxidants addition (sulfur dioxide and glutathione) was investigated during 6 months of aging in bottles. Lower amplitude and temperature, shorter treatment duration and particularly lower frequency showed a more favorable and milder effect on the chemical composition of wine. In the case of the ultrasonic probe treatment, similar effect was achieved primarily by a larger probe diameter as well as lo…

LightnessAntioxidantAcoustics and Ultrasonicsmedicine.medical_treatmentOrganoleptic02 engineering and technology010402 general chemistry01 natural sciencesInorganic Chemistryhigh power ultrasound ; HPU ; wine quality ; antioxidants ; ultrasonic bath ; ultrasonic probe ; artificial neural network (ANN)medicineChemical Engineering (miscellaneous)Environmental ChemistryRadiology Nuclear Medicine and imagingFood scienceChemical compositionAromaWinebiologyChemistryOrganic ChemistryAging of winefood and beverages021001 nanoscience & nanotechnologybiology.organism_classification0104 chemical sciencesComposition (visual arts)0210 nano-technology
researchProduct

Bengali nasal vowels: Lexical representation and listener perception

2022

This paper focuses on the question of the representation of nasality as well as speakers’ awareness and perceptual use of phonetic nasalisation by examining surface nasalisation in two types of vowels in Bengali: underlying nasal vowels (CṼC) and nasalised vowels before a nasal consonant (CVN). A series of three cross-modal forced-choice experiments was used to investigate the hypothesis that only unpredictable nasalisation is stored and that this sparse representation governs how listeners interpret vowel nasality. Visual full-word targets were preceded by auditory primes consisting of CV segments of CVC words with nasal vowels ([tʃɑ̃] for [tʃɑ̃d] ‘moon’), oral vowels ([tʃɑ] for [tʃɑl] ‘un…

Linguistics and LanguageAcoustics and Ultrasonicslexical representationhearer perception; lexical representation; nasal vowels; PhonologyNosePhonologyLanguage and Linguisticshearer perceptionPhoneticsReaction TimeSpeech PerceptionHumansPerceptionnasal vowelsVDP::Humaniora: 000::Språkvitenskapelige fag: 010
researchProduct

Liver Steatosis and Fibrosis in OSA patients After Long-term CPAP Treatment: A Preliminary Ultrasound Study.

2015

In cases of morbid obesity, obstructive sleep apnea (OSA) was associated with biopsy-proven liver damage. The role of non-invasive techniques to monitor liver changes during OSA treatment with continuous positive airway pressure (CPAP) is unknown. We used non-invasive ultrasound techniques to assess liver steatosis and fibrosis in severe OSA patients at diagnosis and during long-term CPAP treatment. Fifteen consecutive patients with severe OSA (apnea hypopnea index 52.5 ± 19.1/h) were studied by liver ultrasound and elastography (Fibroscan) at 6-mo (n = 3) or 1-y (n = 12) follow-up. Mean age was 49.3 ± 11.9 y, body mass index (BMI) was 35.4 ± 6.4 kg/m(2). Adherence to CPAP was ≥5 h/night. A…

Liver CirrhosisMalemedicine.medical_specialtyAcoustics and Ultrasonicsmedicine.medical_treatmentBiophysicsSettore MED/10 - Malattie Dell'Apparato RespiratorioGastroenterologyBody Mass IndexTime03 medical and health sciences0302 clinical medicineFibrosisInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingObesityContinuous positive airway pressureNon-invasive assessmentUltrasonographySleep Apnea ObstructiveRadiological and Ultrasound Technologymedicine.diagnostic_testContinuous Positive Airway Pressurebusiness.industryFatty liverLiver fibrosiMiddle Agedmedicine.diseaseObstructive sleep apneanervous system diseasesrespiratory tract diseasesSurgeryObstructive sleep apneaFatty Liver030228 respiratory systemApnea–hypopnea indexLiverLiver steatosiFeasibility Studies030211 gastroenterology & hepatologyFemaleElastographyLongitudinal studySteatosisbusinessBody mass indexUltrasound in medicinebiology
researchProduct

DOSE–RESPONSE RELATIONSHIPS BETWEEN WHOLE-BODY VIBRATION AND LUMBAR DISK DISEASE—A FIELD STUDY ON 388 DRIVERS OF DIFFERENT VEHICLES

1998

Abstract In a longitudinal study, the dose–response relationships between long term occupational exposure to whole-body vibration and degenerative processes in the lumbar spine caused by the lumbar disks were examined. From 1990 to 1992, 388 vibration-exposed workers from different driving jobs were examined medically and by lumbar X-ray. For each individual, a history of all exposure conditions was recorded, and a cumulative vibration dose was calculated allowing comparisons between groups of low, middle, and high intensity of exposure. 310 subjects were selected for a follow-up four years later, of whom 90·6% (n=281) agreed to participate. In comparing the exposure groups, the results ind…

Longitudinal studymedicine.medical_specialtyAcoustics and Ultrasonicsbusiness.industryMechanical EngineeringDiseaseCondensed Matter PhysicsLumbarMechanics of MaterialsRelative riskAnesthesiaEpidemiologyMedicineWhole body vibrationCumulative incidenceLumbar spinebusinessJournal of Sound and Vibration
researchProduct

Impact of local order and stoichiometry on the ultrafast magnetization dynamics of Heusler compounds

2015

Nowadays, a wealth of information on ultrafast magnetization dynamics of thin ferromagnetic films exists in the literature. Information is, however, scarce on bulk single crystals, which may be especially important for the case of multi-sublattice systems. In Heusler compounds, representing prominent examples for such multi-sublattice systems, off-stoichiometry and degree of order can significantly change the magnetic properties of thin films, while bulk single crystals may be generally produced with a much more well-defined stoichiometry and a higher degree of ordering. A careful characterization of the local structure of thin films versus bulk single crystals combined with ultrafast demag…

Magnetization dynamicsKerr effectMaterials scienceAcoustics and UltrasonicsCondensed matter physicsBand gapDemagnetizing fieldPhysics::OpticsFermi energyElectronic structureCondensed Matter PhysicsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsCondensed Matter::Materials ScienceFerromagnetismCondensed Matter::SuperconductivityThin filmJournal of Physics D: Applied Physics
researchProduct

Interface magnetization of ultrathin epitaxial Co2FeSi(110)/Al2O3films

2007

Element-specific magnetic properties of ultrathin epitaxial Co2FeSi(110) films were measured using x-ray magnetic circular dichroism (XMCD). The epitaxial Heusler films were grown by RF magnetron sputtering on substrates. The magnetization of thicker films as determined by XMCD is smaller than expected for a half-metallic material. In addition, the magnetization decreases considerably for films thinner than 10 nm. The thickness dependence of the magnetic moment can be described by introducing a certain number of dead layers representing a deficiency of magnetization at the interfaces. Quantitative evaluation results in a dead layer thickness of 0.8 nm at room temperature, consisting of a te…

MagnetizationMaterials scienceAcoustics and UltrasonicsMagnetic momentCondensed matter physicsMagnetic circular dichroismDead layerSputter depositionCondensed Matter PhysicsEpitaxyTemperature inducedSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsJournal of Physics D: Applied Physics
researchProduct

Quantitative Ultrasound Bone Measurements in Pre-Pubertal Children with Type 1 Diabetes

2011

This case-control study aimed to assess bone status in children with type 1 diabetes mellitus (T1DM). Fifty-seven pre-pubertal patients (37 boys, aged 7.9 ± 2.5 years, T1DM duration 3.1 ± 1.6 years) and 171 age-matched healthy controls (111 boys) were studied. Quantitative ultrasound (QUS) was used to measure amplitude dependent speed of sound (Ad-SoS) at hand phalanges (expressed as standard deviation score [SDS]). Anthropometric and disease-related data (including mean HbA(1c) from whole T1DM duration [T], last year [Y], examination day [D]) were collected. Mean Ad-SoS SDS in patients -0.13 ± 1.32 (95% confidence interval [CI] -0.48, 0.22) was similar to that of controls. Subgroups discri…

MaleDiabetes durationmedicine.medical_specialtyHbA1cAcoustics and UltrasonicsBiophysicsSensitivity and SpecificityBone MeasurementsBone and BonesInternal medicineDiabetes mellitusmedicineHumansRadiology Nuclear Medicine and imagingChildBoneProspective cohort studyChildrenUltrasonographyType 1 diabetesRadiological and Ultrasound Technologybusiness.industryReproducibility of ResultsAnthropometrymedicine.diseaseConfidence intervalQuantitative ultrasoundDiabetes Mellitus Type 1Type 1 diabetesEndocrinologyChild PreschoolFemalebusinessQuantitative ultrasoundUltrasound in Medicine & Biology
researchProduct

Prenatal exposure to the CB1 receptor agonist WIN 55,212-2 causes learning disruption associated with impaired cortical NMDA receptor function and em…

2005

The aim of this study was to investigate whether prenatal exposure to the cannabinoid CB1 receptor agonist WIN 55,212-2 (WIN) at a daily dose devoid of overt signs of toxicity and/or gross malformations (0.5 mg/kg, gestation days 5-20), influences cortical glutamatergic neurotransmission, learning and emotional reactivity in rat offspring. Basal and K+-evoked extracellular glutamate levels were significantly lower in cortical cell cultures obtained from pups exposed to WIN during gestation with respect to those measured in cultures obtained from neonates born from vehicle-treated dams. The addition of NMDA to cortical cell cultures from neonates born from vehicle-treated dams concentration-…

MaleMarijuana AbuseCannabinoid receptoractive avoidance behaviour; basal and K+-evoked glutamate levels; cortical cell cultures; homing behaviour; maternal marijuana consumption; ultrasonic vocalizationEmotionsReceptor Cannabinoid CB1Pregnancyactive avoidance behaviourWIN 55212-2Cells CulturedCerebral CortexBehavior AnimalGlutamate receptorBraincortical cell culturesCalcium Channel Blockersactive avoidance behaviour; basal and k plus -evoked glutamate levels; basal and k+-evoked glutamate levels; cortical cell cultures; homing behaviour; maternal marijuana consumption; ultrasonic vocalizationPrenatal Exposure Delayed EffectsChloratesNMDA receptorbasal and K+-evoked glutamate levelsFemaleMicrotubule-Associated Proteinsmedicine.drugAgonistmedicine.medical_specialtyOffspringmedicine.drug_classCognitive NeuroscienceMorpholinesGlutamic Acidmaternal marijuana consumptionNeurotransmissionBiologyNaphthalenesReceptors N-Methyl-D-AspartateCellular and Molecular NeuroscienceGlutamatergicInternal medicinemedicineAvoidance LearningAnimalsRats WistarBenzoxazinesRatsultrasonic vocalizationEndocrinologyAnimals Newbornhoming behaviourVocalization AnimalExtracellular SpaceNeuroscience
researchProduct

Comparison of three ultrasonic axial transmission methods for bone assessment.

2005

Abstract This study compared three approaches to bone assessment using ultrasonic axial transmission. In 41 fresh human radii, velocity of the first arriving signal was measured with a commercial device (Sunlight Omnisense ™ ) operating at 1.25 MHz, a prototype based on 1-MHz bidirectional axial transmission and a low-frequency (200 kHz) prototype, also measuring the velocity of a slower wave. Cortical and trabecular bone mineral density, cortical thickness and cross-sectional area were determined by peripheral quantitative computed tomography. Significant but modest correlation between velocities reflects differences in the nature of the propagating waves and methodological differences. Of…

MaleMaterials scienceAcoustics and UltrasonicsBiophysicsSignalBone and BonesBone DensitymedicineCadaverHumansRadiology Nuclear Medicine and imagingUltrasonicsQuantitative computed tomographyAxial transmissionAgedUltrasonographyAged 80 and overRadiological and Ultrasound Technologymedicine.diagnostic_testAnatomyMiddle AgedTrabecular boneRadiusmedicine.anatomical_structureMineral densityCortical boneUltrasonic sensorFemaleBiomedical engineeringUltrasound in medicinebiology
researchProduct