Search results for " vol"
showing 10 items of 3179 documents
Radiofrequency tissue volume reduction for treatment of auricle keloids
2010
Objectives/Hypothesis: Keloids are often refractive to treatment, and recurrences occur quite frequently. Radiofrequency tissue volume reduction (RFTVR) is a surgical technology that induces extensive fibrosis at the target tissues. Methods: We applied RFTVR in 14 patients (19 auricles, 5 patients treated bilaterally; 9 female, 5 male; range, 10–66 years) with keloids of the auricle. Keloids were located at the earlobe in 4 patients (5 auricles), helix in 9 patients (12 auricles), and at both earlobe and helix in 1 patient (2 auricles). In 6 patients (8 auricles) RFTVR was the sole treatment modality applied, and in 7 patients (10 auricles) intralesional steroid injection was also performed…
The effect of training on aerobic power characteristics of young cross-country skiers.
1987
The influences of growth, training and various training methods were investigated by analysing long-term training effects in young cross-country and biathlon skiers (n = 129). Some athletes (n = 49) were studied six times in three years and some at least once a year during a four year period (n = 48). During three summer training periods skiers emphasized either intensive training or distance training or continued to train normally. The results indicated that maximal oxygen uptake (VO2 max) and heart volume increased between 15 and 20 years of age and the most significant changes in heart volume were observed between 16 and 18 years of age. International level skiers were able to increase t…
Relationship of Metabolic Syndrome With Pulse Pressure in Patients With Essential Hypertension
2006
BACKGROUND: Pulse pressure is largely dependent on arterial stiffness. Recent studies have documented reduced large artery compliance in nondiabetic subjects with metabolic syndrome (MS). The aim of our study was to analyze, in a group of patients with essential hypertension and without diabetes mellitus, the influence of MS on clinic and 24-h pulse pressures. METHODS: A total of 528 hypertensive subjects, aged 18 to 72 years, who were free of cardiovascular and renal diseases were enrolled. Of the subjects, 41% had MS. In all subjects routine blood chemistry, echocardiographic examination, and 24-h ambulatory blood pressure monitoring were performed. RESULTS: When compared with subjects wi…
Noninvasive Determination of Anaerobic Threshold Based on the Heart Rate Deflection Point in Water Cycling
2015
This study compared heart rate (HR), oxygen uptake (V[Combining Dot Above]O2), percentage of maximal HR (%HRmax), percentage of maximal V[Combining Dot Above]O2, and cadence (Cad) related to the anaerobic threshold (AT) during a water cycling maximal test between heart rate deflection point (HRDP) and ventilatory (VT) methods. In addition, the correlations between both methods were assessed for all variables. The test was performed by 27 men in a cycle ergometer in an aquatic environment. The protocol started at a Cad of 100 b·min-1 for 3 minutes with subsequent increments of 15 b·min-1 every 2 minutes until exhaustion. A paired two-tailed Student's t-test was used to compare the variables …
Hybrid Functional Electrical Stimulation Exercise Training Alters the Relationship Between Spinal Cord Injury Level and Aerobic Capacity
2014
Objective To test the hypothesis that hybrid functional electrical stimulation (FES) row training would improve aerobic capacity but that it would remain strongly linked to level of spinal cord lesion because of limited maximal ventilation. Design Longitudinal before–after trial of 6 months of FES row training. Setting Exercise for persons with disabilities program in a hospitaL. Participants Volunteers (N=14; age range, 21–63y) with complete spinal cord injury (SCI) (T3-11) who are >2 years postinjury. Intervention Six months of FES row training preceded by a variable period of FES strength training. Main Outcome Measures Peak aerobic capacity and peak exercise ventilation before and after…
Corneal Thickness Response after Anesthetic Eye Drops: Our Own Results and Meta-Analysis.
2017
We aimed to test if there are different patterns in the central corneal thickness (CCT) response after instilling oxybuprocaine anesthetic eye drops and also to determine whether there is a significant change in the CCT. CCT was measured in 60 eyes of 60 healthy subjects before and during the hour after oxybuprocaine 0.4% eye drops were instilled. In addition, a systematic review and meta-analysis were carried out in order to answer the following PICO (patient, intervention, comparison, and outcome) question: What effect do anesthetic eye drops have on CCT values? We found no significant changes in the mean CCT values during the hour’s observation (ANOVA, p=0.209), and the meta-analysis rev…
Dependence of motion sickness in automobiles on the direction of linear acceleration.
1982
Thirty-eight normal volunteers were tested in an ambulance car while being accelerated in one of the following positions: (1) sitting upright facing forward in the car, (2) lying supine on a stretcher head forward, (3) supine position head backward. Consecutive short periods of negative horizontal acceleration (0.7–0.95 g) were achieved by brisk braking manoeuvres of the car, followed by weak reacceleration (0.15 g). Motion sickness symptoms were observed and recorded after each experiment using a special motion sickness scaling index which was weighted according to the strength of any particular symptom. The results indicate that horizontal linear acceleration in a car, such as experienced…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Lithium prevents grey matter atrophy in patients with bipolar disorder: an international multicenter study
2020
AbstractBackgroundLithium (Li) is the gold standard treatment for bipolar disorder (BD). However, its mechanisms of action remain unknown but include neurotrophic effects. We here investigated the influence of Li on cortical and local grey matter (GM) volumes in a large international sample of patients with BD and healthy controls (HC).MethodsWe analyzed high-resolution T1-weighted structural magnetic resonance imaging scans of 271 patients with BD type I (120 undergoing Li) and 316 HC. Cortical and local GM volumes were compared using voxel-wise approaches with voxel-based morphometry and SIENAX using FSL. We used multiple linear regression models to test the influence of Li on cortical an…
Electrophysiological Investigations of Shape and Reproducibility of Oropharyngeal Swallowing: Interaction with Bolus Volume and Age
2015
Electrophysiological assessment provides valuable information on physiological and pathophysiological characteristics of human swallowing. Here, new electrophysiological measures for the evaluation of oropharyngeal swallowing were assessed: (1) the activation pattern of the submental/suprahyoid EMG activity (SHEMG); (2) the reproducibility of the oral and pharyngeal phases of swallowing, by calculating the similarity index (SI) of the SHEMG (SI-SHEMG) and of the laryngeal-pharyngeal mechanogram (SI-LPM) during repeated swallows; and (3) kinesiological measures related to the LPM. An electrophysiological-mechanical method for measuring the activation pattern of the SHEMG, the SI-SHEMG, and t…