Search results for " volunteers"
showing 10 items of 229 documents
Establishing the 99th percentile for high sensitivity cardiac troponin i in healthy blood donors from southern italy
2019
Introduction: The knowledge of high sensitivity cardiac troponin I (hsTnI) distribution in a reference population is mandatory for its introduction in clinical practice. The aim of this study was to define the Upper Reference Limit (URL) of hsTnI measured by Single Molecule Counting technology (SMC) in an accurately selected reference population. Materials and methods: In the study 1140 blood donors were included and selected on the basis of medical history and biomarkers. High sensitivity cardiac troponin I was measured by SMC technology (Clarity, Singulex, Alamed, USA). The 99th percentile was calculated by the non-parametric method according to the Clinical and Laboratory Standard Instit…
TRANSCRANIAL DIRECT CURRENT STIMULATION ENHANCES SUCKING OF A LIQUID BOLUS IN HEALTHY HUMANS
2014
Abstract Background Transcranial direct current stimulation (tDCS) is a non-invasive technique used for modulating cortical excitability in vivo in humans. Here we evaluated the effect of tDCS on behavioral and electrophysiological aspects of physiological sucking and swallowing. Methods Twelve healthy subjects underwent three tDCS sessions (anodal, cathodal and sham stimulation) on separate days in a double-blind randomized order. The active electrode was placed over the right swallowing motor cortex. Repeated sucking and swallowing acts were performed at baseline and at 15 and 60 min after each tDCS session and the mean liquid bolus volume ingested at each time point was measured. We also…
T2-mapping of the sacroiliac joints at 1.5 Tesla: a feasibility and reproducibility study
2018
Objective: To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Materials and methods: Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between…
Long-Term Physical Activity May Modify Brain Structure and Function: Studies in Young Healthy Twins
2019
Background: Physical activity (PA) is said to be beneficial to many bodily functions. However, the effects of PA in the brain are still inadequately known. The authors aimed to uncover possible brain modulation linked with PA. Here, they combine 4 of their studies with monozygotic twins, who were within-pair discordant in PA for a minimum of 1 year. Methods: The authors performed brain imaging, brain electrophysiology, and cardiovascular and body composition assessments, and collected questionnaire-based data. The present synopsis elucidates the differences associated with differing PA history in conditions without genetic variability. They present new structural and electrophysiological re…
Multimodal Device for Real-Time Monitoring of Skin Oxygen Saturation and Microcirculation Function
2019
The present study introduces a recently developed compact hybrid device for real-time monitoring of skin oxygen saturation and temperature distribution. The prototype involves a snapshot hyperspectral camera, multi-wavelength illuminator, thermal camera, and built-in computer with custom-developed software. To validate this device in-vivo we performed upper arm vascular occlusion on eight healthy volunteers. Palm skin oxygen saturation maps were analyzed in real-time using k-means segmentation algorithm and two-layer optical diffuse model. The prototype system demonstrated a satisfying performance of skin hyperspectral measurements in the spectral range of 507&ndash
Reference Values of Thyroid Hormones During the First Trimester of Pregnancy in Valencian Community (Spain) and Their Relationship with Iodine Intake
2020
Thyroid hormones require special monitoring during the first trimester of gestation. Local reference values should be applied if available, especially in iodine-deficient areas, as generalized iodine supplementation is controversial. The aim of the present study was to establish thyroid stimulating hormone (TSH) and free thyroxine (FT4) reference values in the first trimester of gestation in the Valencian community (Spain) and relate them to iodine intake. A total of 261 healthy pregnant women participated in the study. The calculated reference values were 0.128&ndash
A fully automated system for the evaluation of masseter silent periods.
1997
Exteroceptive suppression of masseter muscle activity, 'masseter inhibitory reflex', comprises one or 2 silent periods (SP1 and SP2) interrupting the voluntary activation. The main problem when evaluating exteroceptive suppression is the lack of an objective and precise measure for the onset and end of the silent period which so far has not been overcome by various automated systems. We describe a new fully automated system for determining the onset and end of the masseter silent period. The decision approach is essentially based upon deterministic properties of median filters which are used to partition the local variances of the EMG traces into constant segments and edges between them. Th…
Assessment of haemophilic arthropathy through balance analysis: a promising tool
2019
[EN] The purpose of this study was to develop a tool able to distinguish between subjects who have haemophilic arthropathy in lower limbs and those who do not by analyzing the centre of pressure displacement. The second objective was to assess the possible different responses of haemophiliacs and healthy subjects by creating a classifier that could distinguish between both groups. Fiftyfour haemophilic patients (28 with and 26 without arthropathy) and 23 healthy subjects took part voluntarily in the study. A force plate was used to measure postural stability. A total of 276 centre of pressure displacement parameters were calculated under different conditions: unipedal/bipedal balance with e…
Comparison of Lateral Abdominal Musculature Activation during Expiration with an Expiratory Flow Control Device Versus the Abdominal Drawing-in Maneu…
2020
Background and Objectives: The purpose of the present study was to quantify and compare lateral abdominal musculature thickness, including the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles, via rehabilitative ultrasound imaging (RUSI) during the use of the expiratory flow control device (EFCD) versus the classic abdominal drawing-in maneuver (ADIM). Materials and Methods: A cross-sectional observational pilot study. Twenty-one women were recruited and assessed the thickness of each muscle (TrA, IO, and EO) by ultrasound imaging at rest, during the ADIM, and during expiration with the EFCD. Waist circumference was also measured under the same circumstan…
Effects of intra-session exercise sequence during water-based concurrent training.
2013
The aim was to investigate the effects of the intra-session exercise order during water-based concurrent training on the neuromuscular adaptations in young women. 26 women (25.1±2.9 years) were placed into 2 groups: resistance prior to (RA) or after (AR) aerobic training. Subjects performed resistance (sets at maximal effort) and aerobic training (exercises at heart rate corresponding to the second ventilatory threshold) twice a week over 12 weeks, performing both exercise types in the same training session. Upper (elbow flexion) and lower-body (knee extension) one-repetition maximum test (1RM) and peak torque (PT) were evaluated. The muscle thickness (MT) of upper (sum of MT of biceps brac…