Search results for "030218 nuclear medicine & medical imaging"
showing 10 items of 1054 documents
Intravoxel incoherent motion diffusion-weighted imaging in nonalcoholic fatty liver disease: a 3.0-T MR study.
2012
International audience; PURPOSE: To compare pure molecular diffusion, D, perfusion-related diffusion, D*, and perfusion fraction, f, determined from diffusion-weighted (DW) magnetic resonance (MR) imaging on the basis of the intravoxel incoherent motion (IVIM) theory in patients with type 2 diabetes with and without liver steatosis. MATERIALS AND METHODS: This prospective study was approved by the appropriate ethics committee, and written informed consent was obtained from all patients. Between December 2009 and September 2011, 108 patients with type 2 diabetes (51 men, 57 women; mean age, 50 years) underwent 3.0-T single-voxel point-resolved proton MR spectroscopy of the liver (segment VII…
Diagnostic Performance of Muscle Echo Intensity and Fractal Dimension for the Detection of Frailty Phenotype
2021
To determine the relationship between muscle echo intensity (EI) and fractal dimension (FD), and the diagnostic performance of both ultrasound parameters for the identification of frailty phenotype. A retrospective interpretation of ultrasound scans from a previous cohort (November 2014–February 2015) was performed. The sample included healthy participants <60 years old, and participants ≥60 divided into robust, pre-frail, and frail groups according to Fried frailty criteria. A region of interest of the rectus femoris from the ultrasound scan was segmented, and histogram function was applied to obtain EI. For fractal analysis, images were processed using two-dimensional box-counting techniq…
Reproducibility of CT Radiomic Features within the Same Patient: Influence of Radiation Dose and CT Reconstruction Settings.
2019
Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the reproducibility of radiomic features, as well as to identify correction factors for mitigating these sources of variability. Materials and Methods This was a secondary analysis of a prospective study of metastatic liver lesions in patients who underwent staging with single-energy dual-source contrast material-enhanced staging CT between September 2011 and April 2012. Technique p…
Evaluation of intraindividual contrast enhancement variability for determining the maximum achievable consistency in CT
2019
OBJECTIVE. The purpose of this study was to quantify temporal variability in vascular and parenchymal enhancement within the same patient and to determine technique-related factors contributing to this variability. MATERIALS AND METHODS. We identified 100 patients who underwent four CT scans within 12 months with identical acquisition and contrast injection parameters. Enhancement was recorded in the abdominal aorta, main portal vein, liver parenchyma, and subcutaneous fat. Patient demographic and body habitus data were recorded. Injection-related factors were recorded including delay time from contrast injection to image acquisition. All pairwise differences in enhancement within each pati…
Quantification of epicardial adipose tissue in coronary calcium score and CT coronary angiography image data sets: comparison of attenuation values, …
2016
The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image data sets.In 76 patients (mean age 59 ± 13 years) who underwent CS and CTCA owing to suspected coronary artery disease (CAD), EAT was quantified in terms of density (Hounsfield units), thickness and volume. The EAT volume was extracted with a semi-automatic software.A moderate correlation was found between EAT density in CS and CTCA image data sets (-100 ± 19 HU vs -70 ± 24 HU; p 0.05, r = 0.55). The distribution of EAT was not symmetrical with a maximal thickness at the right atrioventricular groove (14.2 ± 5.3 mm in CS, 15.…
Comparison of Diffusion MRI Acquisition Protocols for the In Vivo Characterization of the Mouse Spinal Cord: Variability Analysis and Application to …
2016
Diffusion-weighted Magnetic Resonance Imaging (dMRI) has relevant applications in the microstructural characterization of the spinal cord, especially in neurodegenerative diseases. Animal models have a pivotal role in the study of such diseases; however, in vivo spinal dMRI of small animals entails additional challenges that require a systematical investigation of acquisition parameters. The purpose of this study is to compare three acquisition protocols and identify the scanning parameters allowing a robust estimation of the main diffusion quantities and a good sensitivity to neurodegeneration in the mouse spinal cord. For all the protocols, the signal-to-noise and contrast-to noise ratios…
Deep Learning Techniques for Automatic MRI Cardiac Multi-Structures Segmentation and Diagnosis: Is the Problem Solved?
2018
Delineation of the left ventricular cavity, myocardium, and right ventricle from cardiac magnetic resonance images (multi-slice 2-D cine MRI) is a common clinical task to establish diagnosis. The automation of the corresponding tasks has thus been the subject of intense research over the past decades. In this paper, we introduce the “Automatic Cardiac Diagnosis Challenge” dataset (ACDC), the largest publicly available and fully annotated dataset for the purpose of cardiac MRI (CMR) assessment. The dataset contains data from 150 multi-equipments CMRI recordings with reference measurements and classification from two medical experts. The overarching objective of this paper is to measure how f…
Discrimination of retinal images containing bright lesions using sparse coded features and SVM
2015
Diabetic Retinopathy (DR) is a chronic progressive disease of the retinal microvasculature which is among the major causes of vision loss in the world. The diagnosis of DR is based on the detection of retinal lesions such as microaneurysms, exudates and drusen in retinal images acquired by a fundus camera. However, bright lesions such as exudates and drusen share similar appearances while being signs of different diseases. Therefore, discriminating between different types of lesions is of interest for improving screening performances. In this paper, we propose to use sparse coding techniques for retinal images classification. In particular, we are interested in discriminating between retina…
[18F]PR04.MZ PET/CT Imaging for Evaluation of Nigrostriatal Neuron Integrity in Patients With Parkinson Disease.
2020
Introduction Degeneration of dopaminergic, nigrostriatal neurons is the hallmark of Parkinson disease (PD), and PET quantification of dopamine transporters is a widely accepted method for differential diagnosis between idiopathic PD and essential tremor. [18F]PR04.MZ is a new PET tracer with excellent imaging properties allowing for precise quantification of striatal and extrastriatal dopamine transporter. Here we describe our initial experience with [18F]PR04.MZ PET/CT in a larger cohort of healthy controls and PD patients as a proof-of-concept study for this tracer. Methods Eighteen healthy subjects, 19 early PD patients (Hoehn-Yahr I–II), and 13 moderate-advanced PD patients (Hoehn-Yahr …
Stereotactic Ablative Radiation Therapy for Lung Oligometastases: Predictive Parameters of Early Response by (18)FDG-PET/CT
2017
Abstract Objectives The objective of this study was to investigate fludeoxyglucose F 18 positron emission tomography/computed tomography ( 18 FDG-PET/CT) parameters as predictive of response after stereotactic ablative radiotherapy (SABR) for lung oligometastases. Methods The inclusion criteria of the current retrospective study were as follows: (1) lung oligometastases treated by SABR, (2) presence of 18 FDG-PET/CT before and after SABR for at least two subsequent evaluations, (3) Karnofsky performance status higher than 80, and (4) life expectancy longer than 6 months. All patients were treated with a biologically equivalent dose of at least 100 Gy with an alpha/beta ratio of 10. The foll…