Influence of core color on final shade reproduction of zirconia crown in single central incisor situation ? An in vivo study
2020
Background A lot of shaded zirconia blocks are being introduced into the market. Their effect on the final shade of the restoration is yet uncertain. Material and methods Twenty-four zirconia crowns were fabricated for 8 patients who needed to restore a single maxillary central incisor, and divided into 3 groups according to the color and type of the zirconia (Zr) used (white Zr core, colored Zr core, and monolithic high translucency (ht) Zr crowns). Using Easyshade spectrophotometer, delta E color difference was calculated between fabricated crown and adjacent tooth. The ΔEs obtained were assessed based on 1.6 ΔE which represented the color difference that could not be detected by the huma…
Influence of substrate design for in vitro mechanical testing
2019
Background: The goal of this study was to evaluate the influence of dental substrate simulator material, and the presence of root and periodontal ligament on the stress distribution in an adhesively-cemented monolithic crown.Material and methods: Five (5) 3D models according to the substrate simulator material and shape were modeled with CAD software for conducting non-linear finite element analysis (FEA): Tooth with and without periodontal ligament - subgroup "pl" (groups Tooth+pl and Tooth-pl), machined tooth in epoxy-resin with and without pulp chamber - subgroup "pc" (ER+pc and ER-pc) and simplified epoxy-resin substrate without pulp chamber and roots (SiER). Next, adhesively-cemented m…
Dental-gingival remodeling with BOPT no-prep veneers
2017
Recent years have seen increasing demand for treatments aimed at improving dental esthetics. In this context, both patients and dentists prefer to preserve dental structures as far as possible; thanks to technological advances, especially in adhesive dentistry, new materials and minimally invasive techniques such as “no-prep” (no preparation) veneers have made this possible. Nevertheless, no-prep veneers have specific indications and suffer certain disadvantages. Objectives: This clinical case describes the rehabilitation of the upper anterior region by means of no-prep veneers, with BOPT (Biologically Oriented Preparation Technique) cervical margins. The patient had requested an aesthetic …
Immediate prosthesis over implants retained using abutments with flexible screws: A preliminary study
2017
Background Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. Material and Methods A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. Results A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and…
Toward completion of the Earth’s proteome: an update a decade later
2017
Protein databases are steadily growing driven by the spread of new more efficient sequencing techniques. This growth is dominated by an increase in redundancy (homologous proteins with various degrees of sequence similarity) and by the incapability to process and curate sequence entries as fast as they are created. To understand these trends and aid bioinformatic resources that might be compromised by the increasing size of the protein sequence databases, we have created a less-redundant protein data set. In parallel, we analyzed the evolution of protein sequence databases in terms of size and redundancy. While the SwissProt database has decelerated its growth mostly because of a focus on i…
Computational fluid dynamics of the ascending aorta before the onset of type A aortic dissection.
2016
We performed a pre-dissection computational fluid analysis of an ascending aortic aneurysm associated with unicuspid aortic valve. The analysis showed an abnormal helical flow pattern inside the aneurysm and an increased wall stress on the right postero-lateral wall of the ascending aorta. These values were largely higher than the theoretical cut-off for aortic wall dissection, their topographic distribution followed the intimal tear site as subsequently diagnosed by computed tomography scan and confirmed during the operation for dissection repair.
Impact of T-cell-mediated immune response on xenogeneic heart valve transplantation: short-term success and mid-term failure.
2017
Objectives Allogeneic frozen cryopreserved heart valves (allografts or homografts) are commonly used in clinical practice. A major obstacle for their application is the limited availability in particular for paediatrics. Allogeneic large animal studies revealed that alternative ice-free cryopreservation (IFC) results in better matrix preservation and reduced immunogenicity. The objective of this study was to evaluate xenogeneic (porcine) compared with allogeneic (ovine) IFC heart valves in a large animal study. Methods IFC xenografts and allografts were transplanted in 12 juvenile merino sheep for 1-12 weeks. Immunohistochemistry, ex vivo computed tomography scans and transforming growth fa…
Markerless 2D kinematic analysis of underwater running : A deep learning approach
2018
Kinematic analysis is often performed with a camera system combined with reflective markers placed over bony landmarks. This method is restrictive (and often expensive), and limits the ability to perform analyses outside of the lab. In the present study, we used a markerless deep learning-based method to perform 2D kinematic analysis of deep water running, a task that poses several challenges to image processing methods. A single GoPro camera recorded sagittal plane lower limb motion. A deep neural network was trained using data from 17 individuals, and then used to predict the locations of markers that approximated joint centres. We found that 300–400 labelled images were sufficient to tra…
static optimal estimation of joint accelerations for inverse dynamics problem solution
2002
In inverse dynamics computations, the accuracy of the solution strongly depends on the accuracy of the input data. In particular, estimated joint moments are highly sensitive to uncertainties in acceleration data. The aim of the present work was to improve classical inverse dynamics computations by providing an accurate estimation of accelerations. Accelerations are usually calculated from noise-polluted position data using numerical double differentiation, which amplifies measurement noise. The objective of the present paper is to use all available imperfect position and force measurements to extract optimum acceleration estimations. A weighted least-squares optimisation approach is used t…
Cytotoxicity, antibacterial and physicochemical properties of a new epoxy resin-based endodontic sealer containing calcium hydroxide
2019
Background This study evaluated the cytotoxicity, antibacterial and physicochemical properties of a new epoxy resin-based endodontic sealer containing calcium-hydroxide Sealer Plus. AH Plus was used as a reference for comparison. Material and Methods Cytotoxicity evaluation was performed according to ISO-10993-5 specifications using MTT assay to check the 3T3 cells viability at 1- to 4-week periods. Antibacterial activity was evaluated using a direct contact test against Enterococcus faecalis. Radiopacity, solubility and flow evaluations were performed according to ISO-6876/2012 specifications. Setting time was assessed following the ANSI/ADA-standard-n.57. The pH level was measured at 3,24…