Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement.
2020
Left ventricular outflow tract (LVOT) obstruction is a feared complication of transcatheter mitral valve replacement (TMVR). This procedure leads to an elongation of LVOT in the left ventricle (namely, the neoLVOT), ultimately portending hemodynamic impairment and death. This study sought to understand the biomechanical implications of LVOT obstruction in two patients who underwent TMVR as an "off-label" application of the Edwards SAPIEN 3 (S3) Ultra transcatheter heart valve (THV). A computational framework of TMVR was developed to assess the neoLVOT area and quantify the sub-aortic flow structure. We observed that the annuloplasty ring serves as the key anchor zone of S3 Ultra THV. A good…
A Multi-Variate Predictability Framework to Assess Invasive Cardiac Activity and Interactions during Atrial Fibrillation
2017
Objective: This study introduces a predictability framework based on the concept of Granger causality (GC), in order to analyze the activity and interactions between different intracardiac sites during atrial fibrillation (AF). Methods: GC-based interactions were studied using a three-electrode analysis scheme with multi-variate autoregressive models of the involved preprocessed intracardiac signals. The method was evaluated in different scenarios covering simulations of complex atrial activity as well as endocardial signals acquired from patients. Results: The results illustrate the ability of the method to determine atrial rhythm complexity and to track and map propagation during AF. Conc…
Three-dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions
2017
Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely "bicuspid aortopathy") is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting from s…
Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire
2019
Background Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected to cyclic fatigue tests. Material and Methods 40 new NiTi instruments with a length of 25 mm were tested: 20 Wave One Gold Medium (WOG), tip size 35 and variable taper (Dentsply Maillefer, Ballaigues, Switzerland) and 20 Edge One Fire (EOF) (EdgeEndo, Albuquerque, New Mexico) tip size 35 and the same variable taper. A mobile support for the electric handpiece and a stainless-steel block containin…
Self-selected running gait modifications reduce acute impact loading, awkwardness, and effort
2021
Impact loading has been associated with running-related injuries, and gait retraining has been suggested as a means of reducing impact loading and lowering the risk of injury. However, gait retraining can lead to increased perceived awkwardness and effort. The influence of specifically trained and self-selected running gait modifications on acute impact loading, perceived awkwardness and effort is currently unclear. Sixteen habitual rearfoot/midfoot runners performed forefoot strike pattern, increased step rate, anterior trunk lean and self-selected running gait modifications on an instrumented treadmill based on real-time biofeedback. Impact loading, perceived awkwardness and effort scores…
Effect of the Alterations in Contractility and Morphology Produced by Atrial Fibrillation on the Thrombosis Potential of the Left Atrial Appendage
2021
Atrial fibrillation (AF) is a common arrhythmia mainly affecting the elderly population, which can lead to serious complications such as stroke, ischaemic attack and vascular dementia. These problems are caused by thrombi which mostly originate in the left atrial appendage (LAA), a small muscular sac protruding from left atrium. The abnormal heart rhythm associated with AF results in alterations in the heart muscle contractions and in some reshaping of the cardiac chambers. This study aims to verify if and how these physiological changes can establish hemodynamic conditions in the LAA promoting thrombus formation, by means of computational fluid dynamic (CFD) analyses. In particular, sinus …
Information transfer and information modification to identify the structure of cardiovascular and cardiorespiratory networks
2017
To fully elucidate the complex physiological mechanisms underlying the short-term autonomic regulation of heart period (H), systolic and diastolic arterial pressure (S, D) and respiratory (R) variability, the joint dynamics of these variables need to be explored using multivariate time series analysis. This study proposes the utilization of information-theoretic measures to measure causal interactions between nodes of the cardiovascular/cardiorespiratory network and to assess the nature (synergistic or redundant) of these directed interactions. Indexes of information transfer and information modification are extracted from the H, S, D and R series measured from healthy subjects in a resting…
Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation
2020
The severity of aortic stenosis (AS) has traditionally been graded by measuring hemodynamic parameters of transvalvular pressure gradient, ejection jet velocity, or estimating valve orifice area. Recent research has highlighted limitations of these criteria at effectively grading AS in presence of left ventricle (LV) dysfunction. We hypothesized that simulations coupling the aorta and LV could provide meaningful insight into myocardial biomechanical derangements that accompany AS. A realistic finite element model of the human heart with a coupled lumped-parameter circulatory system was used to simulate AS. Finite element analysis was performed with Abaqus FEA. An anisotropic hyperelastic mo…
Modern Strategies in the Prevention of Implant-Associated Infections
2005
The application of medical devices either for temporary or permanent use has become an indispensible part of almost all fields of medicine. However, foreign bodies are associated with a substantial risk of bacterial and fungal infections. Implant-associated infections significantly contribute to the still increasing problem of nosocomial infections. To reduce the incidence of such infections, specific guidelines providing evidence-based recommendations and comprising both technological and nontechnological strategies for prevention have been established. Strict adherence to hygienic rules during insertion or implantation of the device are aspects of particular importance. Besides such basi…
Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system
2016
Background: The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Material and Methods: Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the …