Search results for "302"
showing 10 items of 27399 documents
Partial discharge detection and localization along medium voltage cables
2017
In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a MV cable and to locate the pulse source through the time arrival difference of the pulses obtained from two sensors installed separately.
Selective Band Gap to Suppress the Spurious Acoustic Mode in Film Bulk Acoustic Resonator Structures
2018
In this work, we investigate numerically the propagation of Lamb waves in a film bulk acoustic resonator (FBAR) structure formed by piezoelectric ZnO layer sandwiched between two Mo electrodes coupled with Bragg reflectors; the system is thus considered as a phononic-crystal (PnC) plate. The aim is to suppress the first-order symmetric Lamb wave mode considered as a spurious mode caused by the establishment of a lateral standing wave due to the reflection at the embedded lateral extremities of the structure; this spurious mode is superposing to the main longitudinal mode resonance of the FBAR. The finite element study, using harmonic and eigen-frequency analyses, is performed on the section…
Cold gas dynamic spray technology: A comprehensive review of processing conditions for various technological developments till to date
2018
Abstract Today, cold gas dynamic spray (CGDS) technology has thrived with considerable capabilities for manufacturing various technological depositions. The deposition conditions have been developed through many years and that have led to produce ample experimental data which is available in the literature. But, recent research and development activities also reveal innovative findings regarding various deposition conditions. This paper contains a review of experimental deposition procedures for the cold spray additive manufacturing. Details of processing conditions are reported and classified into various categories of baseline working conditions, specific processing including deposition o…
2018
Damping distances of surface plasmon polariton modes sustained by different thin titanium nitride (TiN) films are measured at the telecom wavelength of 1.55 μm. The damping distances are correlated to the electrical direct current resistivity of the films sustaining the surface plasmon modes. It is found that TiN/Air surface plasmon mode damping distances drop non-linearly from 40 to 16μm as the resistivity of the layers increases from 28 to 130μΩ.cm, respectively. The relevance of the direct current (dc) electrical resistivity for the characterization of TiN plasmonic properties is investigated in the framework of the Drude model, on the basis of parameters extracted from spectroscopic ell…
Emerging blue-UV luminescence in cerium doped YAG nanocrystals
2016
Physica status solidi / Rapid research letters 10(6), 475 - 479(2016). doi:10.1002/pssr.201600041
High-Performance Flexible Magnetic Tunnel Junctions for Smart Miniaturized Instruments
2018
Current Spreading Length and Injection Efficiency in ZnO/GaN-Based Light-Emitting Diodes
2019
We report on carrier injection features in light-emitting diodes (LEDs) based on nonintentionally doped-ZnO/p-GaN heterostructures. These LEDs consist of a ZnO layer grown by chemical-bath deposition (CBD) onto a p-GaN template without using any seed layer. The ZnO layer (~1- $\mu \text{m}$ thickness) consists of a dense collection of partially coalesced ZnO nanorods, organized in wurtzite phase with marked vertical orientation, whose density depends on the concentration of the solution during the CBD process. Due to the limited conductivity of the p-GaN layer, the recombination in the n-region is strongly dependent on the spreading length of the holes, ${L}_{h}$ , coming from the p-contact…
A new Collinear Apparatus for Laser Spectroscopy and Applied Science (COALA).
2020
We present a new collinear laser spectroscopy setup that has been designed to overcome systematic uncertainty limits arising from high-voltage and frequency measurements, beam superposition, and collisions with residual gas that are present in other installations utilizing this technique. The applied methods and experimental realizations are described, including an active stabilization of the ion-source potential, new types of ion sources that have not been used for collinear laser spectroscopy so far, dedicated installations for pump-and-probe measurements, and a versatile laser system referenced to a frequency comb. The advanced setup enables us to routinely determine transition frequenci…
Guiding and splitting Lamb waves in coupled-resonator elastic waveguides
2018
Abstract We investigate experimentally Lamb wave propagation in coupled-resonator elastic waveguides (CREWs) formed by a chain of cavities in a two-dimensional phononic crystal slab with cross holes. Wide complete bandgaps, extending from 53 to 88 kHz, are first measured in a finite phononic crystal slab sample. A straight waveguide and a wave splitting circuit with 90° bends are then designed, fabricated and measured. Elastic Lamb waves are excited by a piezoelectric patch attached to one side of the phononic slab and detected using a scanning vibrometer. Strongly confined guiding and splitting at waveguide junctions are clearly observed for several guided waves. Numerical simulations are …
Experimental and numerical investigation of laboratory crystal growth furnace for the development of model-based control of CZ process
2019
Abstract The presented study is focused on laboratory Czochralski crystal growth experiments and their mathematical modelling. The developed small-scale CZ crystal growth furnace is described as well as the involved automation systems: crystal radius detection by image recognition, temperature sensors, adjustable heater power and crystal pull rate. The CZ-Trans program is used to model the experimental results – transient, 2D axisymmetric simulation software primarily used for modelling of the industrial-scale silicon crystal growth process. Poor agreement with the experimental results is reached; however, the proven ability to perform affordable, small-scale experiments and successfully mo…