Search results for "ABDOMINAL AORTIC ANEURYSM"

showing 10 items of 81 documents

Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…

2020

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…

Malemedicine.medical_specialtyAortographyTime FactorsComputed Tomography Angiographymedicine.medical_treatmentComputed tomographyDiagnostic accuracy030204 cardiovascular system & hematology030230 surgeryLikelihood ratios in diagnostic testingEndovascular aneurysm repairAortography03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsPredictive Value of TestsColor duplex ultrasoundMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesUltrasonography Doppler ColorProspective cohort studyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresReproducibility of Resultsmedicine.diseaseAbdominal aortic aneurysmTreatment OutcomeRetreatmentFemaleRadiologyFranceCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalCirculation. Cardiovascular imaging
researchProduct

High incidence of venous thrombosis after surgery for abdominal aortic aneurysm

2009

Objective The incidence of venous thromboembolism (VT) after aortic abdominal aneurysm (AAA) surgery is imprecisely reported. On one hand, thromboprophylaxis has improved, on the other hand, AAA patients have become older and/or present worse comorbidities. Herein, we prospectively analyzed the incidence of VT in a continuous series of patients operated on for AAA repair and looked for predictive factors. Materials and Methods Between January 1, 2005, and December, 31, 2006, 193 consecutive patients (177 men and 16 women), mean age 73 (range, 47-93) underwent elective AAA repair, 137 open (71%) and 56 endovascular (29%), in our institution. Thromboprophylaxis consisted of thigh-length compr…

Malemedicine.medical_specialtyDeep veinDrug Administration ScheduleAortic aneurysmRisk FactorsmedicineHumansProspective StudiesEnoxaparinEarly AmbulationAgedUltrasonographyAged 80 and overVenous Thrombosisbusiness.industryHeparinIncidenceAnticoagulantsTransfusion ReactionPerioperativeVenous ThromboembolismMiddle Agedmedicine.diseaseThrombosisAbdominal aortic aneurysmSurgeryVenous thrombosismedicine.anatomical_structureTreatment OutcomeAnesthesiaSurgeryFemaleFresh frozen plasmaCardiology and Cardiovascular MedicinebusinessVascular Surgical ProceduresStockings CompressionAbdominal surgeryAortic Aneurysm AbdominalJournal of Vascular Surgery
researchProduct

Renewed endovascular repair for recurrent acute abdominal aortic aneurysm

2008

The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperative…

Malemedicine.medical_specialtyEndoleak type IIIRecurrent acuteSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationPostoperative ComplicationsRecurrenceEndovascular repairBack painmedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesAcute abdominal aortic aneurysmAged 80 and overEndoleak type IIbusiness.industrymedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeTreatment Outcomecardiovascular systemEmergency MedicineRadiologymedicine.symptombusinessTomography X-Ray ComputedAortic Aneurysm Abdominal
researchProduct

Editor's Choice – Occurrence and Classification of Proximal Type I Endoleaks After EndoVascular Aneurysm Sealing Using the Nellix™ Device

2017

Objective/Background Proximal type I endoleaks are associated with abdominal aortic aneurysm (AAA) growth and rupture and necessitate repair. The Nellix™ EndoVascular Aneurysm Sealing (EVAS) system is a unique approach to AAA repair, where the appearance and treatment of endoleaks is also different. This study aimed to analyse and categorise proximal endoleaks in an EVAS treated cohort. Methods All patients, treated from February 2013 to December 2015, in 15 experienced EVAS centres, presenting with proximal endoleak were included. Computed tomography scans were analysed by a core laboratory. A consensus meeting was organised to discuss and qualify each case for selection, technical aspects…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentTechnical successEarly detectionComputed tomography030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmRisk FactorsHumansMedicineAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryIncidenceIncidence (epidemiology)Endovascular ProceduresStentMiddle Agedmedicine.diseaseAbdominal aortic aneurysmSurgeryTreatment OutcomeFemaleSurgeryCore laboratoryCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalEuropean Journal of Vascular and Endovascular Surgery
researchProduct

A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.

2015

Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentparallel graftTarget vesselmorbidityperiscope graftEndovascular aneurysm repairpararenal aortic aneurysmSettore MED/22 - Chirurgia Vascolarelaw.inventionendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmlawRecurrencethoracoabdominal aortic aneurysmMedicineHumansRadiology Nuclear Medicine and imagingIn patientChimneyself-expanding covered stentVascular PatencyAgedabdominal aortic aneurysm; chimney graft; endoleak; endovascular aneurysm repair; morbidity; mortality; parallel graft; pararenal aortic aneurysm; patency; periscope graft; reintervention; self-expanding covered stent; stent-graft; target vessel; thoracoabdominal aortic aneurysmreinterventionstent-graftbusiness.industryEndovascular ProceduresChimney graftchimney graftmedicine.diseasemortalityAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisSurvival RateTreatment OutcomeSurgeryFemalePeriscopeCardiology and Cardiovascular Medicinebusinesspatencytarget vesselAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

The predictive role of atherogenic dyslipidemia in subjects with non-coronary atherosclerosis

2009

Abstract Background Recent findings have suggested that subjects with non-coronary atherosclerosis may show elevated prevalence of atherogenic dyslipidemia, including higher triglyceride levels, reduced HDL-cholesterol concentrations and increased levels of small, dense low-density lipoproteins (LDL). These three lipid abnormalities constitute the so-called “atherogenic-lipoprotein-phenotype” (ALP) but its predictive role in these patients still remains to be established. Methods We performed a 2-year follow-up study to assess clinical and biochemical predictors of cardiovascular events in 44 male patients (64 ± 5 years, BMI: 27 ± 3), 26 with peripheral arterial disease and 18 with abdomina…

Malemedicine.medical_specialtyMultivariate analysis1303 BiochemistryClinical Biochemistry10265 Clinic for Endocrinology and Diabetology610 Medicine & health1308 Clinical Biochemistry2704 Biochemistry (medical)Biochemistrychemistry.chemical_compoundRisk Factorsatherogenic dyslipidemiaInternal medicineDiabetes mellitusmedicineHumansFamily historyCoronary atherosclerosisDyslipidemiasPeripheral Vascular DiseasesUnivariate analysisTriglyceridebusiness.industryBiochemistry (medical)Cholesterol LDLGeneral MedicineMiddle AgedAtherosclerosismedicine.diseaseAbdominal aortic aneurysmPeripheralPhenotypechemistryCase-Control StudiesMultivariate AnalysisCardiologyAtherosclerosis HDL-cholesterol Triglycerides Small dense LDL Atherogenic lipoprotein phenotypebusinessAortic Aneurysm AbdominalFollow-Up Studies
researchProduct

A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm

2013

We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.

Malemedicine.medical_specialtyRadiology Nuclear Medicine and ImagingBridging (networking)Common iliac aneurysmProsthesis DesignIliac ArterySettore MED/22 - Chirurgia VascolareWire-loop techniqueFollow-Up StudieBlood Vessel Prosthesis ImplantationmedicineStentHumanscardiovascular diseasesAgedEndovascular; Iliac aneurysm; Wire-loop technique; Aged; Aortic Aneurysm Abdominal; Blood Vessel Prosthesis Implantation; Follow-Up Studies; Humans; Iliac Aneurysm; Iliac Artery; Male; Prosthesis Design; Treatment Outcome; Blood Vessel Prosthesis; Stents; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineRuptured abdominal aortic aneurysmEndovascularbusiness.industrySynthetic graftStandard techniqueSurgeryBlood Vessel ProsthesisIliac aneurysmBlood Vessel Prosthesisurgical procedures operativemedicine.anatomical_structureTreatment OutcomeStentsRadiologybusinessCardiology and Cardiovascular MedicineWire loopArteryFollow-Up StudiesAortic Aneurysm AbdominalHuman
researchProduct

Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…

2016

Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…

Malemedicine.medical_specialtyThree dimensional analysisTime FactorsEndoleak3d analysisComputed tomography030204 cardiovascular system & hematologyProsthesis DesignAortography030218 nuclear medicine & medical imagingBlood Vessel Prosthesis Implantation03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineAneurysmForeign-Body MigrationPredictive Value of TestsHumansMedicineRadiology Nuclear Medicine and imagingAgedRetrospective StudiesComputed tomography angiographyAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresMean ageMiddle Agedmedicine.diseaseAbdominal aortic aneurysmBlood Vessel ProsthesisTreatment OutcomeRadiographic Image Interpretation Computer-AssistedFemaleStentsSurgeryRadiologyCardiology and Cardiovascular MedicinebusinessAfter treatmentAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

A Multicenter Experience With a New Fenestrated-Branched Device for Endovascular Repair of Thoracoabdominal Aortic Aneurysms.

2018

To investigate the outcomes of patients who were treated for thoracoabdominal aortic aneurysms (TAAAs) using custom-made fenestrated-branched stent-grafts.A consecutive series of 108 patients (mean age 73.5 years; 73 men) with TAAA were treated with E-xtra Design Engineering customized fenestrated-branched stent-grafts between November 2011 and January 2017. Data on baseline characteristics, procedures, and clinical follow-up were collected from 6 regional European surgical centers for retrospective analysis of endoleaks, reinterventions, and target vessel patency. The median aneurysm diameter was 6.75 cm (range 5.5-13). The distribution of the TAAA according to the modified Crawford classi…

Malemedicine.medical_specialtyTime Factors030204 cardiovascular system & hematologyThoracoabdominal Aortic AneurysmsProsthesis Design03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsRisk FactorsmedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseases030212 general & internal medicineVascular PatencyAgedRetrospective StudiesAged 80 and overAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresSpinal cord ischemiaMiddle AgedSurgeryBlood Vessel ProsthesisEuropesurgical procedures operativeTreatment Outcomecardiovascular systemSurgeryFemaleStentsCardiology and Cardiovascular MedicinebusinessJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Mid-Term Results of Endovascular Aneurysm Sealing in the Treatment of Abdominal Aortic Aneurysm With Unfavorable Morphology.

2020

Purpose: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR). Methods: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of m…

Malemedicine.medical_specialtyTime FactorsDatabases Factualmedicine.medical_treatmentMid term results030204 cardiovascular system & hematologyEndovascular aneurysm repairRisk AssessmentNellix device03 medical and health sciencesBlood Vessel Prosthesis Implantationabdominal aortic aneurysm0302 clinical medicineAneurysmPostoperative ComplicationsRisk Factorschimney graftsmedicineHumans030212 general & internal medicineVascular PatencyAgedendovascular aneurysm sealingbusiness.industryEndovascular ProceduresGeneral MedicineMiddle Agedmedicine.diseaseAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisProsthesis FailureTreatment OutcomeSurgeryFemaleStentsCardiology and Cardiovascular Medicinebusinessoutside IFUAortic Aneurysm AbdominalVascular and endovascular surgery
researchProduct