Search results for "ACCURACY"

showing 10 items of 277 documents

Modeling wave propagation in elastic solids via high-order accurate implicit-mesh discontinuous Galerkin methods

2022

A high-order accurate implicit-mesh discontinuous Galerkin framework for wave propagation in single-phase and bi-phase solids is presented. The framework belongs to the embedded-boundary techniques and its novelty regards the spatial discretization, which enables boundary and interface conditions to be enforced with high-order accuracy on curved embedded geometries. High-order accuracy is achieved via high-order quadrature rules for implicitly-defined domains and boundaries, whilst a cell-merging strategy addresses the presence of small cut cells. The framework is used to discretize the governing equations of elastodynamics, written using a first-order hyperbolic momentum-strain formulation…

Implicitly-defined meshesMechanical EngineeringApplied MathematicsMathematicsofComputing_NUMERICALANALYSISComputational MechanicsDiscontinuous Galerkin methodsGeneral Physics and AstronomyImplicitly-defined mesheNumerical Analysis (math.NA)Mathematical SciencesComputer Science ApplicationsHigh-order accuracyEngineeringMechanics of MaterialsEmbedded-boundary methodDiscontinuous Galerkin methodFOS: MathematicsElastodynamicsEmbedded-boundary methodsMathematics - Numerical Analysis
researchProduct

Quadrature coils for magnetic resonance spectroscopy in the detection of prostate cancer: Single voxel acquisition does not improve the diagnostic ac…

2011

Abstract Objective To determine the viability of quadrature coils for detecting prostate cancer using single voxel and multivoxel spectroscopy images. Material and methods We used a quadrature coil on a 1.5T MR scanner to evaluate 23 patients with suspected prostate cancer and prostate specific antigen levels greater than 4 ng/ml (mean 12 ± 8 ng/ml), independently of findings at digital rectal examination. We acquired T2-weighted images and MR spectroscopy images. We also acquired single voxel studies in areas in which the T2-weighted images or the multivoxel images were altered. We used a citrate solution to verify the spectroscopic calibration. Results Using spectroscopy images and a (Cho…

In vivo magnetic resonance spectroscopyMaterials sciencebusiness.industrySingle voxelDiagnostic accuracyNuclear magnetic resonance spectroscopymedicine.diseaseProstate cancerProstate-specific antigenNuclear magnetic resonancemedicineGeneral Earth and Planetary SciencesCutoffSpectroscopyNuclear medicinebusinessGeneral Environmental ScienceRadiología (English Edition)
researchProduct

Randomized pilot study and qualitative evaluation of a clinical decision support system for brain tumour diagnosis based on SV 1H MRS: Evaluation as …

2014

The results of a randomized pilot study and qualitative evaluation of the clinical decision support system Curiam BT are reported. We evaluated the system's feasibility and potential value as a radiological information procedure complementary to magnetic resonance (MR) imaging to assist novice radiologists in diagnosing brain tumours using MR spectroscopy (1.5 and 3.0T). Fifty-five cases were analysed at three hospitals according to four non-exclusive diagnostic questions. Our results show that Curiam BT improved the diagnostic accuracy in all the four questions. Additionally, we discuss the findings of the users' feedback about the system, and the further work to optimize it for real envir…

In vivo magnetic resonance spectroscopyRandomized pilot studymedicine.medical_specialtymedicine.diagnostic_testbusiness.industryBrain tumoursClinical decision support systemsHealth InformaticsDiagnostic accuracyMagnetic resonance imagingQualitative evaluationClinical decision support systemComputer Science ApplicationsClinical trialFISICA APLICADAMedicineRadiological information procedureMedical physicsbusinessSimulation
researchProduct

Accuracy evaluation of orthodontic movements with aligners: a prospective observational study.

2022

Abstract Background Since their introduction in orthodontics, clear aligners have been appreciated by patients, including adults, for their comfort and low aesthetic impact. Despite the enormous mobilization of financial resources all over the world aimed at producing new product lines, few clinical studies or high-quality evidence have been produced regarding the real effectiveness of such treatment. Given the few limited kinds of research on the subject, this study aims to produce and critically evaluate other data, to establish the concrete reliability of clear aligners in orthodontic therapy. Results Significant sample sizes were obtained for intrusion, vestibulo/lingual (V/L) crown tip…

IncisorCuspidTooth Movement TechniquesAccuracy Aligner treatment Orthodontic forces Orthodontic tooth movement Orthodontic predictability assessment InvisalignSettore MED/28 - Malattie OdontostomatologicheOrthodontic Appliances RemovableHumansOrthodontic Appliance DesignReproducibility of ResultsOrthodontics
researchProduct

The smoothed particle hydrodynamics method via residual iteration

2019

Abstract In this paper we propose for the first time an iterative approach of the Smoothed Particle Hydrodynamics (SPH) method. The method is widespread in many areas of science and engineering and despite its extensive application it suffers from several drawbacks due to inaccurate approximation at boundaries and at irregular interior regions. The presented iterative process improves the accuracy of the standard method by updating the initial estimates iterating on the residuals. It is appealing preserving the matrix-free nature of the method and avoiding to modify the kernel function . Moreover the process refines the SPH estimates and it is not affected by disordered data distribution. W…

Iterative and incremental developmentComputer scienceMechanical EngineeringComputational MechanicsProcess (computing)General Physics and Astronomy010103 numerical & computational mathematicsBivariate analysisIterated residualResidual01 natural sciencesComputer Science Applications010101 applied mathematicsSmoothed-particle hydrodynamicsSettore MAT/08 - Analisi NumericaDistribution (mathematics)Smoothed particle hydrodynamicMechanics of MaterialsConvergence (routing)Test functions for optimization0101 mathematicsConvergenceAlgorithmAccuracyKernel based method
researchProduct

Accuracy of the clinical diagnosis of dementia with Lewy bodies (DLB) among the Italian Dementia Centers: a study by the Italian DLB study group (DLB…

2022

Introduction: Dementia with Lewy bodies (DLB) may represent a diagnostic challenge, since its clinical picture overlaps with other dementia. Two toolkits have been developed to aid the clinician to diagnose DLB: the Lewy Body Composite Risk Score (LBCRS) and the Assessment Toolkit for DLB (AT-DLB). We aim to evaluate the reliability of these two questionnaires, and their ability to enhance the interpretation of the international consensus diagnostic criteria. Methods: LBCRS and AT-DLB were distributed to 135 Italian Neurological Centers for Cognitive Decline and Dementia (CDCDs), with the indication to administer them to all patients with dementia referred within the subsequent 3 months. We…

Lewy Body DiseaseClinical diagnosiDementia with Lewy bodieConsensus criteriaDementia with Lewy bodiesDermatologybehavioral disciplines and activitiesDiagnostic accuracyDiagnosis DifferentialAlzheimer DiseaseDiagnosismental disordersHumansReproducibility of ResultsDiagnostic toolkitGeneral MedicineClinical diagnosis; Cognitive impairment; Consensus criteria; Dementia; Dementia with Lewy bodies; Diagnostic accuracy; Diagnostic toolkitsClinical diagnosisnervous system diseasesSettore MED/26 - NEUROLOGIAPsychiatry and Mental healthCognitive impairmentItalyDifferentialDiagnostic toolkitsDementiaNeurology (clinical)
researchProduct

qFIBS: A Novel Automated Technique for Quantitative Evaluation of Fibrosis, Inflammation, Ballooning, and Steatosis in Patients With Nonalcoholic Ste…

2020

[Background and Aims] Nonalcoholic steatohepatitis (NASH) is a common cause of chronic liver disease. Clinical trials use the NASH Clinical Research Network (CRN) system for semiquantitative histological assessment of disease severity. Interobserver variability may hamper histological assessment, and diagnostic consensus is not always achieved. We evaluate a second harmonic generation/two‐photon excitation fluorescence (SHG/TPEF) imaging‐based tool to provide an automated quantitative assessment of histological features pertinent to NASH.

Liver CirrhosisMale0301 basic medicineBiopsyChronic liver diseaseSeverity of Illness IndexGastroenterologyHepatitis0302 clinical medicineNon-alcoholic Fatty Liver DiseaseFibrosisNonalcoholic fatty liver diseaseqFibrosisNASH; automated; qFIBS; qFibrosis; quantitative evaluationNASH FIBROSISmedicine.diagnostic_testNASHMiddle AgedReference Standards3. Good healthLiverDimensional Measurement AccuracyLiver biopsyFemale030211 gastroenterology & hepatologyAlgorithmsmedicine.medical_specialtydigestive systemWhite People03 medical and health sciencesAsian PeopleInternal medicineImage Interpretation Computer-AssistedSeverity of illnessmedicineHumansqFIBSHepatologyReceiver operating characteristicbusiness.industryReproducibility of Resultsmedicine.diseasequantitative evaluationdigestive system diseasesConfidence intervalFatty Liver030104 developmental biologyautomatedSteatosisbusinessHepatology
researchProduct

Design, implementation, and evaluation of the adolescents and surveillance system for the obesity prevention project

2016

Abstract The Adolescents Surveillance System for Obesity prevention (ASSO) Project aimed at developing standardized and web-based tools for collecting data on adolescents’ obesity and its potential determinants. This has been implemented and piloted in the local area of Palermo city, Italy. The aim of the present study is to provide an overview of the Project's design, implementation, and evaluation, highlighting all the aspects for a potential scale-up of the surveillance system on the whole national territory and abroad, as a sustainable and effective source of data. The overall structure and management, the ASSO-toolkit, the ASSO-NutFit software, and all developed and used procedures for…

Male0301 basic medicineProgram evaluationPediatric ObesityProcess managementQuality managementAdolescentObesity fitness testing cardiorespiratory assessment body compositionMEDLINE03 medical and health sciencesSoftware DesignSurveys and QuestionnairesInterimQuality Improvement StudyHumansMedicineObesityLife StyleSWOT analysisInternetbody composition6600030109 nutrition & dieteticsData collectionbusiness.industryData CollectionHealth Plan ImplementationGeneral MedicineQuality Improvementcardiorespiratory assessmentData AccuracyItalyfitness testingPopulation SurveillanceMEDICINE Adolescents Surveillance System for Obesity prevention (ASSO) ProjectSoftware designFemaleThe InternetbusinessResearch Article
researchProduct

Head-to-head comparison of plasma cTnI concentration values measured with three high-sensitivity methods in a large Italian population of healthy vol…

2019

Abstract Background The study aim is to compare cTnI values measured with three high-sensitivity (hs) methods in apparently healthy volunteers and patients admitted to emergency department (ED) with acute coronary syndrome enrolled in a large multicentre study. Methods Heparinized plasma samples were collected from 1511 apparently healthy subjects from 8 Italian clinical institutions (mean age: 51.5 years, SD: 14.1 years, range: 18–65 years, F/M ratio:0.95). All volunteers denied chronic or acute diseases and had normal values of routine laboratory tests. Moreover, 1322 heparinized plasma sample were also collected by 9 Italian clinical institutions from patients admitted to ED with clinica…

Male0301 basic medicineprincipal component analysisvery elderlyClinical BiochemistryheparinizationBiochemistryPatient Admission0302 clinical medicineReference ValuesLimit of Detectionblood analysisTroponin IHealthy volunteers80 and overMyocardial infarctionAcute coronary syndrome; Cardiac troponins; High-sensitivity methods; Myocardial infarction; Reference population values; Acute Coronary Syndrome; Adolescent; Adult; Aged; Aged 80 and over; Blood Chemical Analysis; Female; Humans; Italy; Male; Middle Aged; Myocardium; Patient Admission; Reference Values; Troponin I; Young Adult; Emergency Service Hospital; Healthy Volunteers; Limit of DetectionReference population valuescomparative studyHigh-sensitivity methodsAged 80 and overemergency wardEmergency Servicehospital emergency servicetroponin I acute coronary syndromeSettore BIO/12clinical trialGeneral Medicinecardiac troponin 1 CLIAMiddle AgedHealthy Volunteerspriority journalItaly030220 oncology & carcinogenesisCardiac troponinFemaleAcute coronary syndromeEmergency Service HospitalAdultmedicine.medical_specialtyAcute coronary syndromecardiac muscleAdolescentHead to headheart infarctionArticleYoung AdultHospital03 medical and health sciencesbloodInternal medicinemedicinesexHumanscontrolled studyADVIA Centaurdiagnostic test accuracy studyhumannormal humanproceduresAgedbusiness.industryMyocardiumTroponin IBiochemistry (medical)reference valueEmergency departmentmedicine.diseasemajor clinical studyhospital admissionyoung adult Acute Coronary SyndromeHigh-sensitivity methodMyocardial infarctionmulticenter study030104 developmental biologySettore BIO/12 - Biochimica Clinica E Biologia Molecolare Clinicaageprotein blood levelReference valuesCardiac troponinsbusinessmetabolismBlood Chemical Analysis
researchProduct

Influence of image reconstruction parameters on cardiovascular risk reclassification by Computed Tomography Coronary Artery Calcium Score

2018

Objective: To investigate the influence of different CT reconstruction parameters on coronary artery calcium scoring (CACS) values and reclassification of predicted cardiovascular (CV) risk. Methods: CACS was evaluated in 113 patients undergoing ECG-gated 64-slice CT. Reference CACS protocol included standard kernel filter (B35f) with slice thickness/increment of 3/1.5 mm, and field-of-view (FOV) of 150–180 mm. Influence of different image reconstruction algorithms (reconstructed slice thickness/increment 2.0/1.0–1.5/0.8–3.0/2.0–3.0/3.0 mm; slice kernel B30f-B45f; FOV 200–250 mm) on Agatston score was assessed by Bland-Altman plots and concordance correlation coefficient (CCC) ana…

MaleAccuracy and precisionRadiology Nuclear Medicine and ImagingCardiac computed tomographyComputed Tomography AngiographyComputed tomographyIterative reconstructionCoronary Artery Disease030204 cardiovascular system & hematologyRisk Assessment030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImage reconstruction algorithmRisk FactorsImage Processing Computer-AssistedMedicineHumansReconstruction parameterProspective StudiesVascular CalcificationAgedReconstruction parametersmedicine.diagnostic_testCoronary artery calcium scorebusiness.industryCoronary artery calcium scoreCardiovascular risk classificationGeneral MedicineMiddle AgedCardiovascular riskConcordance correlation coefficientCardiovascular DiseasesCardiac computed tomography; Cardiovascular risk; Cardiovascular risk classification; Coronary artery calcium score; Reconstruction parametersFemalebusinessAgatston scoreNuclear medicineSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCoronary Artery Calcium ScoringAlgorithms
researchProduct