Search results for "ACL"

showing 10 items of 906 documents

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

2017

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

AdultMaleCorneal PachymetryIntraclass correlationmedicine.medical_treatmentCoefficient of variationBiomedical Engineeringlaw.inventionCorneaYoung Adult03 medical and health sciences0302 clinical medicineOpticslawRefractive surgerymedicineHumansCorneal pachymetryMathematicsKeratometermedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCorneal topographySpherical aberration030221 ophthalmology & optometryFemaleSurgerybusinessTomography Optical Coherence030217 neurology & neurosurgeryBiomedical engineeringExpert Review of Medical Devices
researchProduct

Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.

2012

Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…

AdultMaleCorneal Wavefront AberrationIntraclass correlationZernike polynomialsmedicine.medical_treatmentRefraction Ocularsymbols.namesakeYoung AdultOpticsRefractive surgeryAberrometrymedicineHumansProspective StudiesMathematicsWavefrontObserver VariationReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityWavefront sensorMiddle AgedRefractive ErrorsOphthalmologysymbolsOptometryFemalebusinessAmerican journal of ophthalmology
researchProduct

Severe meningo-/encephalitis after daclizumab therapy for multiple sclerosis.

2019

Background: Daclizumab is a monoclonal antibody that binds the high-affinity interleukin-2 receptor and was approved for the treatment of relapsing multiple sclerosis. Due to severe inflammatory brain disorders, the approval was suspended in March 2018. Objective and Methods: This retrospective cohort study summarizes clinical, laboratory, radiological, and histological findings of seven patients who developed meningo-/encephalitis after daclizumab therapy. Results: Patients presented with encephalitis and/or meningitis and suffered from systemic symptoms such as fever (5/7), exanthema (5/7), or gastrointestinal symptoms (4/7). Secondary autoimmune diseases developed. Blood analysis reveale…

AdultMaleDaclizumabMultiple Sclerosismedicine.drug_classMonoclonal antibodyAutoimmune Diseases03 medical and health sciences0302 clinical medicineDaclizumabmedicineHumansLymphocytes030304 developmental biologyRetrospective Studies0303 health sciencesbusiness.industryMultiple sclerosisMeningoencephalitisAntibodies MonoclonalBrainMiddle Agedmedicine.disease3. Good healthNeurologyImmunologyEncephalitisFemaleNeurology (clinical)business030217 neurology & neurosurgeryEncephalitisImmunosuppressive Agentsmedicine.drugMultiple sclerosis (Houndmills, Basingstoke, England)
researchProduct

Comparing indirect methods of digit ratio (2D:4D) measurement.

2008

The ratio of the lengths of the second and fourth finger (2D:4D) has been proposed to index prenatal exposure to androgens. Different methods have been utilized to measure digit ratio, however, their measurement precision and economy have not been systematically compared yet. Using different indirect methods (plastic ruler, caliper, computer software), three independent raters measured finger lengths of 60 participants. Generally, measurement precision (intraclass correlation coefficient, technical error of measurement, and relative technical error of measurement) was acceptable for each method. However, precision estimates were highest for the computer software, indicating excellent measur…

AdultMaleDigit ratioAnthropometryIntraclass correlationbusiness.industryFourth fingerContrast (statistics)Reproducibility of ResultsFingersSoftwareSample size determinationAnthropologyStatisticsGeneticsAndrogensCalipersHumansFemaleAnatomybusinessEcology Evolution Behavior and SystematicsReliability (statistics)SoftwareMathematicsAmerican journal of human biology : the official journal of the Human Biology Council
researchProduct

Reliability and validity of the form 90 interview.

2004

<i>Objective:</i> Alcohol consumption is a central variable in substance abuse research and treatment. The study reports the psychometric characteristics of the German version of the Form 90 interview for the assessment of recent alcohol consumption. <i>Method:</i> Reliability was evaluated in a test-retest study (7 days) with 30 consecutively admitted psychiatric inpatients with alcohol dependence. Validity of Form 90 was assessed with a second sample of 60 alcohol-dependent inpatients. <i>Results:</i> Form 90 demonstrated good to excellent retest reliability for the central variables of alcohol consumption. Retest reliability Pearson correlation coeffic…

AdultMaleHealth (social science)Alcohol DrinkingPsychometricsIntraclass correlationSubstance-Related DisordersTemperanceStatistics as TopicMedicine (miscellaneous)AlcoholComorbidityMedical RecordsAlcohol Withdrawal Deliriumchemistry.chemical_compoundsymbols.namesakeGermanyInterview PsychologicalmedicineHumansReliability (statistics)Mental DisordersAlcohol dependenceReproducibility of ResultsMiddle Agedmedicine.diseaseConfidence intervalPearson product-moment correlation coefficientSubstance abuseHospitalizationPsychiatry and Mental healthAlcoholismchemistryStructured interviewsymbolsPatient ComplianceFemalePsychologyClinical psychologyFollow-Up StudiesEuropean addiction research
researchProduct

Posterior tibial tendon dysfunction: Clinical and magnetic resonance imaging findings having histology as reference standard.

2017

Abstract Objective To investigate the correlation between MRI, clinical tests, histopathologic features of posterior tibial tendon (PTT) dysfunction in patients with acquired adult flatfoot deformity surgically treated with medializing calcaneal osteotomy and flexor digitorum longus tendon transposition. Materials and methods Nineteen patients (11 females; age: 46 ± 15 year, range 18–75) were pre-operatively evaluated using the single heel rise (HR) and the first metatarsal rise (FMR) sign tests. Two reviewers graded the PTT tears on a I–III scale and measured the hindfoot valgus angle on the pre-operative MRI of the ankle. The specimens of the removed portion of PTT were histologically ana…

AdultMaleHistologyHeelAdolescentIntraclass correlationmedicine.medical_treatmentOsteotomyPreoperative care030218 nuclear medicine & medical imagingTendons03 medical and health sciencesYoung Adult0302 clinical medicineRetrospective StudiePreoperative CaremedicineHumansRadiology Nuclear Medicine and imagingPosterior Tibial Tendon DysfunctionTendonAgedRetrospective Studies030222 orthopedicsmedicine.diagnostic_testbusiness.industryFootMagnetic resonance imagingGeneral MedicineMiddle AgedReference Standardsmedicine.diseaseSingle heel riseFlatfootMagnetic Resonance ImagingOsteotomymedicine.anatomical_structureTendinopathyReference StandardFemaleHindfoot valguFirst metatarsal rise signTendinopathyAnklebusinessNuclear medicinePosterior Tibial Tendon DysfunctionHumanEuropean journal of radiology
researchProduct

Intra and intersession repeatability and reliability of the S-Plate® pressure platform.

2017

Abstract Aim The aim of this study was to assess the repeatability and reliability of the S-Plate® pressure platform in a group of healthy subjects. Material and methods Forty subjects, free from physical conditions that would affect normal gait, walked along a five-meter corridor while data were recorded from the pressure platform. A total of 10 steps (five each side) were obtained as well as five static trials; the same measurements were repeated one week later. Peak and mean plantar pressures and contact area were recorded for both dynamic and static trials. Additionally, weight supported on each limb was documented during static trials. To assess intrasession and intersession repeatabil…

AdultMaleIntraclass correlationCoefficient of variationBiophysicsWalking03 medical and health sciences0302 clinical medicinePlate pressurePressureHumansOrthopedics and Sports MedicineGaitReliability (statistics)MathematicsOrthodonticsFootPlantar pressureRehabilitationHealthy subjectsReproducibility of Results030229 sport sciencesRepeatabilityBiomechanical PhenomenaNormal gaitExercise TestFemale030217 neurology & neurosurgeryGaitposture
researchProduct

Reliability, validity and responsiveness of the EQ-5D in assessing and valuing health status in patients with social phobia

2013

Abstract Objective The aim of the study was to analyse the psychometric properties of the EQ-5D in patients with social phobia. Methods We used a sample of 445 patients with social phobia with five measurement points over a 30 month period. The discriminative ability of the EQ-5D was analysed by comparing the patients’ responses with the general population and between different disease severity levels. For test-retest reliability we assessed the level of agreement in patients’ responses over time, when there was no change in the Liebowitz Social Anxiety Scale (LSAS). Construct validity was analysed by identifying correlations of the EQ-5D with more specific instruments. For responsiveness w…

AdultMaleIntraclass correlationHealth StatusPopulationLiebowitz social anxiety scaleValidityPhobic disorderYoung Adult03 medical and health sciences0302 clinical medicineEQ-5DGermanySurveys and QuestionnairesmedicineHumansddc:610030212 general & internal medicineeducationeducation.field_of_studyResearchEQ-5DPublic Health Environmental and Occupational HealthBeck Depression InventoryReproducibility of ResultsConstruct validityResponsivenessGeneral MedicineMiddle AgedReliability030227 psychiatryPhobic DisordersQuality of LifeAnxietyFemalemedicine.symptomSocial phobiaPsychologyClinical psychology
researchProduct

Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.

1999

This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both th…

AdultMaleKnee JointPhysiologyVastus medialisIntraclass correlationIsometric exerciseElectromyographyBicepsIsometric ContractionMedicineHumansMuscle SkeletalHydrotherapyReproducibilityKnee extensorsmedicine.diagnostic_testbusiness.industryElectromyographyPublic Health Environmental and Occupational HealthReproducibility of ResultsWaterAnatomyElectrophysiologyFemalebusinessBiomedical engineeringEuropean journal of applied physiology and occupational physiology
researchProduct

Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…

2007

Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…

AdultMaleLightPsychometricsIntraclass correlationLensletDiagnostic Techniques OphthalmologicalEyeRefraction OcularModels BiologicalSensitivity and SpecificityStandard deviationOpticsmedicineImage Processing Computer-AssistedHumansScattering RadiationMathematicsbusiness.industryObjective measurementCentroidReproducibility of ResultsSmall sampleRepeatabilitySensory SystemsOphthalmologymedicine.anatomical_structureOptometrySurgeryHuman eyeFemalebusinessJournal of cataract and refractive surgery
researchProduct