Search results for "ACOUSTIC"

showing 10 items of 1590 documents

Contribution of thallium-201-SPECT to the grading of tumorous alterations of the brain

1992

Single photon emission computed tomography (SPECT) with thallium-201-chloride (201Tl) was used in 22 patients to assess the grade of malignancy of brain tumors. Low- and high-grade malignant gliomas could be well differentiated by calculating the Grade Index (GI), i.e., 201Tl uptake in the tumor area relative to a contralateral brain region. Low-grade gliomas (WHO-grade I-II) usually showed a GI of1.5. Tumors classified histologically as high-grade malignant (WHO-grade III-IV) had GI values greater than 1.42 and a mean value of 1.89. Until labelled amino-acid tracers for gamma-cameras become commercially available, thallium-201 brain-SPECT can provide an independent and complementary method…

AdenomaAdultMalemedicine.medical_specialtychemistry.chemical_elementAstrocytomaSingle-photon emission computed tomographyMalignancyDiagnosis DifferentialMeningeal NeoplasmsmedicineHumansPituitary NeoplasmsGrading (tumors)AgedNeoplasm StagingTomography Emission-Computed Single-Photonmedicine.diagnostic_testBrain Neoplasmsbusiness.industryBrainGliomaNeuroma AcousticGeneral MedicineMiddle Agedmedicine.diseaseThallium RadioisotopeschemistryPositron emission tomographyThalliumFemaleSurgeryNeurology (clinical)NeurosurgeryMeningiomabusinessNuclear medicineNeurosurgical Review
researchProduct

Tissue characterization of benign brain tumors: Use of NMR-tissue parameters

1988

Abstract To evaluate the potentials of NMR tissue parameters for tissue characterization we investigated 68 patients with benign brain tumors. Tissue parameters were accurately measured by a recently developed interlaced triple sequence. Each individual tumor was characterized by a set of three numbers (relaxation times T 1 and T 2 and proton density Rho). Different tumors exhibited significant overlaps of the three tissue parameters. Therefore a reliable prediction of the histological diagnosis based on the quantitative analysis of tissue parameters alone was not possible. T 2 -prolongation correlated well with water content and “regressive changes” in meningiomas and neuromas.

AdenomaPathologymedicine.medical_specialtyBrain NeoplasmsChemistryBiomedical EngineeringBiophysicsBenign brain tumorsBrainNeuroma AcousticTissue characterizationImage EnhancementMagnetic Resonance ImagingModels StructuralCraniopharyngiomaBody WaterHistological diagnosismedicineHumansPituitary NeoplasmsRadiology Nuclear Medicine and imagingMeningiomaProton densityQuantitative analysis (chemistry)Magnetic Resonance Imaging
researchProduct

SINGLE-TRIAL BASED INDEPENDENT COMPONENT ANALYSIS ON MISMATCH NEGATIVITY IN CHILDREN

2010

Independent component analysis (ICA) does not follow the superposition rule. This motivates us to study a negative event-related potential — mismatch negativity (MMN) estimated by the single-trial based ICA (sICA) and averaged trace based ICA (aICA), respectively. To sICA, an optimal digital filter (ODF) was used to remove low-frequency noise. As a result, this study demonstrates that the performance of the sICA+ODF and aICA could be different. Moreover, MMN under sICA+ODF fits better with the theoretical expectation, i.e., larger deviant elicits larger MMN peak amplitude.

AdolescentLearning DisabilitiesComputer Networks and CommunicationsSpeech recognitionMismatch negativityElectroencephalographyGeneral MedicineIndependent component analysisNoiseAcoustic StimulationAttention Deficit Disorder with HyperactivityEvoked Potentials AuditoryHumansSingle trialChildEvoked PotentialsDigital filterAlgorithmsMathematicsInternational Journal of Neural Systems
researchProduct

Amusic does not mean unmusical: Beat perception and synchronization ability despite pitch deafness

2013

Pitch deafness, the most commonly known form of congenital amusia, refers to a severe deficit in musical pitch processing (i.e., melody discrimination and recognition) that can leave time processing--including rhythm, metre, and "feeling the beat"--preserved. In Experiment 1, we show that by presenting musical excerpts in nonpitched drum timbres, rather than pitched piano tones, amusics show normal metre recognition. Experiment 2 reveals that body movement influences amusics' interpretation of the beat of an ambiguous drum rhythm. Experiment 3 and a subsequent exploratory study show an ability to synchronize movement to the beat of popular dance music and potential for improvement when give…

AdultAuditory perceptionmedicine.medical_specialtyCognitive NeuroscienceEmotionsExperimental and Cognitive PsychologyAmusiaAudiologyDiscrimination PsychologicalRhythmArts and Humanities (miscellaneous)otorhinolaryngologic diseasesDevelopmental and Educational PsychologymedicineHumansPitch PerceptionBeat deafnessCommunicationbusiness.industryAuditory Perceptual DisordersBody movementmedicine.diseasehumanitiesPersons With Hearing ImpairmentsNeuropsychology and Physiological PsychologyAcoustic StimulationTone deafnessCase-Control Studiesta6131Auditory PerceptionFemalebusinessPsychologyBeat (music)MusicPitch (Music)Cognitive Neuropsychology
researchProduct

Ultrasonographic Detection of Vascularity of Focal Breast Lesions: Microvascular Imaging Versus Conventional Color and Power Doppler Imaging.

2021

To compare microvascular flow imaging (MVFI) to conventional Color-Doppler (CDI) and Power-Doppler (PDI) imaging in the detection of vascularity of Focal Breast Lesions (FBLs). A total of 180 solid FBLs (size: 3.5–45.2 mm) detected in 180 women (age: 21–87 years) were evaluated by means of CDI, PDI, and MVFI. Two blinded reviewers categorized lesion vascularity in absent or present, and vascularity pattern as (a) internal; (b) vessels in rim; (c) combined. The presence of a “penetrating vessel” was assessed separately. Differences in vascularization patterns (chi2 test) and intra- and inter-observer agreement (Fleiss method) were calculated. ROC analysis was performed to assess performance…

AdultBreast Neoplasms01 natural sciencesSensitivity and Specificity030218 nuclear medicine & medical imagingDiagnosis Differential03 medical and health sciencessymbols.namesakePower dopplerYoung Adult0302 clinical medicineVascularity0103 physical sciencesmedicineHumansRadiology Nuclear Medicine and imagingBreastUltrasonography Doppler Color010301 acousticsAgedAged 80 and overRadiological and Ultrasound Technologybusiness.industryUltrasonography DopplerMiddle AgedROC CurvesymbolsFemalebreast Doppler imaging microvessels ultrasonographymedicine.symptomUltrasonographyNuclear medicinebusinessDoppler effectMicrovascular flowUltrasonic imaging
researchProduct

The influence of temporal factors on automatic priming and conscious expectancy in a simple reaction time task.

2009

In a previous study, we reported a dissociation between subjective expectancy and motor behaviour in a simple associative learning task (Perruchet, Cleeremans, & Destrebecqz, 2006). According to previous conditioning studies (Clark, Manns, & Squire, 2001), this dissociation is observed when the to-be-associated events coterminate and thus overlap in time (a training regimen called delay conditioning), but not when they are separated by a temporal delay (trace conditioning). In this latter situation indeed, there tends to be a direct relationship between subjective expectancy and behaviour. In this study, we further investigated this issue in a series of experiments where conscious …

AdultDissociation (neuropsychology)Time FactorsAdolescentConsciousnessPhysiologymedia_common.quotation_subjectExperimental and Cognitive PsychologyStimulus (physiology)Neuropsychological TestsAutomatism (medicine)Developmental psychologyYoung AdultPhysiology (medical)medicineReaction TimeHumansAttentionGeneral Psychologymedia_commonExpectancy theoryAnalysis of VarianceCognitionGeneral MedicineAutomatismAssociative learningSurpriseInhibition PsychologicalNeuropsychology and Physiological PsychologyAcoustic Stimulationmedicine.symptomPsychologyPriming (psychology)Psychomotor PerformanceCognitive psychologyQuarterly journal of experimental psychology (2006)
researchProduct

Sound-Induced Flash Illusions Support Cortex Hyperexcitability in Fibromyalgia

2022

Objectives. Fibromyalgia (FM) is characterized by spontaneous chronic widespread pain in combination with hyperalgesia to pressure stimuli. Sound-induced flash illusions (SIFIs) reflect cross-modal interactions between senses allowing to assess a visual cortical hoerexcitability (VCH) by evaluating the fission and fusion illusions disruption. The aims of the present study were to explore whether SIFIs are perceived differently in patients with fibromyalgia as compared to healthy controls (HCs) and how migraine affects fission and fusion illusions in fibromyalgia. Methods. A single flash (F) accompanied by 0 to 4 beeps (B) was presented to induce the fission illusion while multiple flash (i.…

AdultFibromyalgiaArticle SubjectMigraine DisordersInfant NewbornAnxietyMiddle AgedIllusionsAnesthesiology and Pain MedicineNeurologyIllusionMigraine DisorderAcoustic StimulationAuditory PerceptionHumansSettore MED/26 - NeurologiaFemalePhotic StimulationHumanPain Research and Management
researchProduct

Detection of sound rise time by adults with dyslexia

2005

Low sensitivity to amplitude modulated (AM) sounds is reported to be associated with dyslexia. An important aspect of amplitude modulation cycles are the rise and fall times within the sound. In this study, simplified stimuli equivalent to just one cycle were used and sensitivity to varying rise times was explored. Adult participants with dyslexia or compensated dyslexia and a control group performed a detection task with sound pairs of different rise times. Results showed that the participants with dyslexia differed from the control group in rise time detection and a correlation was found between rise time detection and reading and phonological skills. A subgroup of participants with lower…

AdultHandwritingLinguistics and Languagemedicine.medical_specialtyLoudness PerceptionCognitive Neurosciencemedia_common.quotation_subjectExperimental and Cognitive PsychologyAudiologybehavioral disciplines and activitiesLanguage and LinguisticsDevelopmental psychologyPhonemic contrastDyslexiaSpeech and HearingPhoneticsCommunication disorderReading (process)PerceptionReaction TimemedicineHumansLanguage disordermedia_commonDyslexiaCognitionmedicine.diseaseAcoustic StimulationPattern Recognition VisualReadingRise timePsychologyBrain and Language
researchProduct

Measures of native and non-native rhythm in a quantity language.

2005

The traditional phonetic classification of language rhythm as stress-timed or syllable-timed is attributed to Pike. Recently, two different proposals have been offered for describing the rhythmic structure of languages from acoustic-phonetic measurements. Ramus has suggested a metric based on the proportion of vocalic intervals and the variability ( SD) of consonantal intervals. Grabe has proposed Pairwise Variability Indices (nPVI, rPVI) calculated from the differences in vocalic and consonantal durations between successive syllables. We have calculated both the Ramus and Grabe metrics for Latvian, traditionally considered a syllable rhythm language, and for Latvian as spoken by Russian l…

AdultLinguistics and LanguageSociology and Political ScienceAdolescentFirst languageMultilingualism050105 experimental psychologyLanguage and LinguisticsSpeech Acoustics030507 speech-language pathology & audiology03 medical and health sciencesSpeech and HearingRhythmPhoneticsHumansLearning0501 psychology and cognitive sciencesAcoustic phoneticsMathematicsPikecomputer.programming_languageAgedLanguagePsycholinguistics05 social sciencesIndo-European languagesLatvianPhoneticsGeneral MedicineMiddle Agedlanguage.human_languageLinguisticslanguageSpeech PerceptionSyllable0305 other medical sciencecomputerPsychoacousticsLanguage and speech
researchProduct

Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatit…

2011

Transient elastography (TE) is adequate for a diagnosis of cirrhosis, but its accuracy for milder stages of fibrosis is much less satisfactory. The objective of this study was to compare the performance and the discordance rate of acoustic radiation force impulse (ARFI) and TE with liver biopsy in a cohort of chronic hepatitis C (CHC) patients.One hundred thirty-nine consecutive patients with CHC were enrolled in two tertiary centers, and evaluated for histological (Metavir score) and biochemical features. All patients underwent TE and ARFI.TE was unreliable in nine patients (6.5%), while in no cases (0%) were ARFI invalid measurements recorded (P=0.029). By area under receiver operating ch…

AdultLiver CirrhosisMalemedicine.medical_specialtyHepacivirusLiver fibrosisBiopsyHepacivirusImpulse (physics)behavioral disciplines and activitiesCohort StudiesElasticity Imaging TechniquesBiopsyotorhinolaryngologic diseasesMedicineHumansProspective StudiesAcoustic radiation forceAgedHepatologybiologymedicine.diagnostic_testbusiness.industryarfi fibroscan hcv fibrosisGastroenterologyReproducibility of ResultsHepatitis CHepatitis C ChronicMiddle Agedbiology.organism_classificationmedicine.diseaseROC CurveElasticity Imaging TechniquesRNA ViralFemalesense organsRadiologyTransient elastographybusinesspsychological phenomena and processes
researchProduct