Search results for "ACOUSTIC"
showing 10 items of 1590 documents
Correlation of local disorder and electronic properties in the Heusler alloy Co2Cr0.6Fe0.4Al
2007
For the fully ordered Heusler alloy Co2Cr0.6Fe0.4Al half-metallic ferromagnetism has been predicted. Local disorder other than the Al–Cr/Fe (B2)-type disorder is known to destroy the half-metallic bandgap. The usage of appropriate buffer layers improves the structural quality of thin films. We correlate the structural properties of thin magnetron sputtered films determined by x-ray diffraction with details of the x-ray magnetic circular dichroism spectra. From the value of the magnetic moment located at the Cr atom and features of the Co absorption spectra we conclude that the buffer layers lead also to an improvement in the local atomic order. The atomic ordering gradually approaches the l…
Using the methods of radiospectroscopy (EPR, NMR) to study the nature of the defect structure of solid solutions based on lead zirconate titanate (PZ…
2014
The nature of intrinsic and impurity point defects in lead zirconate titanate (PZT) ceramics has been explored. Using electron paramagnetic resonance (EPR), nuclear magnetic resonance (NMR), and X-ray photoelectron spectroscopy (XPS) methods, several impurity sites have been identified in the materials, including the Fe 3+ -oxygen vacancy (VO) complex and Pb ions. Both of these centers are incorporated into the PZT lattice. The Fe 3+ -V paramagnetic complex serves as a sensitive probe of the local crystal field in the ceramic; the symmetry of this defect roughly correlates with PZT phase diagram as the composition is varied from PbTiO 3 to PbZrO 3 . NMR spectra 207 Pb in PbTiO 3 , PbZrO 3 ,…
Influence of laser–target interaction regime on composition and properties of surface layers grown by laser treatment of Ti plates
2009
Surface laser treatment of commercially pure titanium plates was performed in air using two different Nd : YAG sources delivering pulses of 5 and 35 ns. The laser fluence conditions were set to obtain with each source either yellow or blue surface layers. Nuclear reaction analysis (NRA) was used to quantify the amount of light elements in the formed layers. Titanium oxinitrides, containing different amounts of oxygen and nitrogen, were mainly found, except in the case of long pulses and high laser fluence, which led to the growth of titanium dioxide. The structure of the layers was studied by x-ray diffraction and Raman spectroscopy. In addition, reflectance spectra showed the transition fr…
Ultrasonic cavitation induced water in vegetable oil emulsion droplets--a simple and easy technique to synthesize manganese zinc ferrite nanocrystals…
2012
In the present investigation, synthesis of manganese zinc ferrite (Mn(0.5)Zn(0.5)Fe(2)O(4)) nanoparticles with narrow size distribution have been prepared using ultrasound assisted emulsion (consisting of rapeseed oil as an oil phase and aqueous solution of Mn(2+), Zn(2+) and Fe(2+) acetates) and evaporation processes. The as-prepared ferrite was nanocrystalline. In order to remove the small amount of oil present on the surface of the ferrite, it was subjected to heat treatment at 300 °C for 3h. Both the as-prepared and heat treated ferrites have been characterized by X-ray diffraction (XRD), infrared spectroscopy (IR), TGA/DTA, transmission electron microscopy (TEM) and energy dispersion X…
Covalent bonding and the nature of band gaps in some half-Heusler compounds
2005
Half-Heusler compounds \textit{XYZ}, also called semi-Heusler compounds, crystallize in the MgAgAs structure, in the space group $F\bar43m$. We report a systematic examination of band gaps and the nature (covalent or ionic) of bonding in semiconducting 8- and 18- electron half-Heusler compounds through first-principles density functional calculations. We find the most appropriate description of these compounds from the viewpoint of electronic structures is one of a \textit{YZ} zinc blende lattice stuffed by the \textit{X} ion. Simple valence rules are obeyed for bonding in the 8-electron compound. For example, LiMgN can be written Li$^+$ + (MgN)$^-$, and (MgN)$^-$, which is isoelectronic wi…
Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.
2013
Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…
Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study
2007
Determination of cortical bone thickness is warranted, e.g., for assessing the level of endosteal resorption in osteoporosis or other bone pathologies. We have shown previously that the velocity of the fundamental antisymmetric (or flexural) guided wave, measured for bone phantoms and bones in vitro, correlates with the cortical thickness significantly better than those by other axial ultrasound methods. In addition, we have introduced an inversion scheme based on guided wave theory, group velocity filtering and 2-D fast Fourier transform, for determination of cortical thickness from the measured velocity of guided waves. In this study, the method was validated for tubular structures by usi…
Thickness sensitivity of ultrasound velocity in long bone phantoms
2004
One approach to bone disease diagnosis such as osteoporosis is to measure the velocity of ultrasound propagating axially along long bones. In this study, the variation in velocity as a function of radial position was assessed using two polyvinyl chloride (PVC) bone phantoms with cross-sectional geometry similar to the human tibia but differing in medullary cavity diameter. Two ultrasonometers were used: these were a commercial device operating at a relatively high frequency (HF) of 1.25 MHz and a prototype low frequency (LF) device operating at approximately 200 kHz. The LF measurements showed a larger variation with radial position, with changes in velocity of up to 20% occurring around th…
Improvement of oxidation resistance of polymer-based nanocomposites through sonication of carbonaceous nanoparticles
2020
Abstract The work aim is focused on two different aspects: first, the investigation of the effect of extended ultra-sound-assisted treatment (us) of carbonaceous nanoparticles, such as carbon nanotubes (CNTs) and carbon black (CB), on their radical scavenging activity, and second, the investigation of the oxidative resistance of polymer-based nanocomposites, containing us-treated CNTs and CB. Particularly, the CNTs and CB have been subjected to us sonication for different time intervals and the performed analysis reveals that both kinds of nanoparticles show decreased average hydrodynamic diameters and large content of surface defects. Really, the increased content of CNTs and CB defects, a…