Search results for "ALLOYS"

showing 10 items of 1689 documents

A preliminary comparison between finite element and meshless simulations of extrusion

2009

In this paper the extrusion process of a cross-shaped profile was investigated. In particular, the study was focused on the distortion of extruding profiles when the workpiece and die axis are not aligned. The process was simulated using the finite element method (FEM) and the natural element method (NEM), both implemented in an updated-Lagrangian formulation, in order to avoid the burden associated with the description of free surfaces in ALE or Eulerian formulations. Furthermore, an experimental equipment was developed in order to obtain reliable data in terms of deformed entity, required process load and calculated pressure. At the end, a comparison between the numerical predictions and …

Regularized meshless methodMaterials scienceFinite element limit analysisbusiness.industryMetals and AlloysMixed finite element methodStructural engineeringBoundary knot methodIndustrial and Manufacturing EngineeringFinite element methodDiscrete element methodComputer Science Applicationsextrusion modellingModeling and SimulationCeramics and CompositesSmoothed finite element methodmeshless methodbusinessSettore ING-IND/16 - Tecnologie E Sistemi Di LavorazioneExtended finite element methodJournal of Materials Processing Technology
researchProduct

Review of methodologies for evaluating university social responsability

2015

The article presents a review of methodologies for the assessment of the so-called University Social Responsibility from the analysis of indicator systems in the area of higher education in Ibero-America. A publication-based research was conducted, compiling progress made between the years 2006-2013. A total of two doctoral theses that presented evaluation systems in students; two models proposed by universities in Peru and Spain; and the papers of two university networks that designed a University Social Responsibility conceptual development and indicator systems for its assessment were identified. The article points out that despite the spectrum of conceptual proposals produced during the…

Responsabilidad socialLC8-6691metodologíasMechanical EngineeringResponsabilidad SocialMetals and Alloysmethodologyeducación superiorSocial responsibilityIbero-americaLSpecial aspects of educationEducationIberoaméricaMetodologíasMechanics of Materialshigher educationEducación superiorIberoamérica.
researchProduct

Influence of some relevant process parameters on the dimensional accuracy in incremental forming: a numerical and experimental investigation

2004

Abstract As known, incremental forming is a flexible and innovative sheet metal forming process which allows complex shape shells forming without the need for any die. For these reasons, incremental forming is nowadays suggested for rapid prototyping and customised products. The present paper is focused on material formability in incremental forming and, in particular, on the evaluation and compensation of elastic springback. The latter significantly modifies the imposed shape. For this purpose, a deeper assessment of the process was developed following three different approaches. First of all, a wide experimental investigation on the influence of some relevant process parameters was develo…

Reverse engineeringFEMEngineeringbusiness.product_categorybusiness.industryIncremental formingDesign toolMetals and AlloysProcess (computing)Forming processesStructural engineeringGeometrical accuracycomputer.software_genreIndustrial and Manufacturing EngineeringFinite element methodComputer Science ApplicationsModeling and Simulationvisual_artCeramics and Compositesvisual_art.visual_art_mediumFormabilityDie (manufacturing)Sheet metalbusinesscomputerJournal of Materials Processing Technology
researchProduct

Crystal structure and microstructure of synthetic hexagonal magnesium–cobalt cordierite solid solutions (Mg2−2xCo2xAl4Si5O18)

2013

Co2+-containing cordierite glasses, of nominal compositions (Mg1−xCox)2Al4Si5O18(withx= 0, 0.2, 0.4, 0.6, 0.8 and 1), were prepared by melting colloidal gel precursors. After isothermal heating at 1273 K for around 28 h, a single-phase α-cordierite (high-temperature hexagonal polymorph) was synthesized. All materials were investigated using X-ray powder diffraction and field-emission scanning electron microscopy. The crystal structure and microstructure were determined from X-ray diffraction patterns. Rietveld refinement confirmed the formation of magnesium–cobalt cordierite solid solutions. The unit-cell volume increased with the increase of cobalt content in the starting glass. The crysta…

Rietveld refinementChemistryMetals and AlloysNucleationCordieriteGeneral Medicineengineering.materialMicrostructureGeneral Biochemistry Genetics and Molecular BiologyAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionCrystallographylawMaterials ChemistryengineeringCrystalliteCrystallizationPowder diffractionSolid solutionActa Crystallographica Section B Structural Science, Crystal Engineering and Materials
researchProduct

Structure determination of three polymorphs of xylazine from laboratory powder diffraction data

2014

The crystal structures of three xylazine hydrochloride [N-(2,6-dimethylphenyl)-5,6-dihydro-4H-1,3-thiaz-2-amine hydrochloride] polymorphsA,ZandXhave been solved from powder diffraction data and refined using Rietveld refinement. Data were obtained with Cu Kα radiation. All polymorphs were found to have structures withZ′ = 1 andZ= 4. All the structures determined contained strong hydrogen bonds between the amino groups and chloride anions. The crystal structures of formsAandXfeatured π–π stacking interactions.

Rietveld refinementHydrogen bondChemistryHydrochlorideMetals and AlloysStackingCrystal structureChlorideAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialschemistry.chemical_compoundCrystallographyPolymorphism (materials science)Materials ChemistrymedicinePowder diffractionmedicine.drugActa Crystallographica Section B Structural Science, Crystal Engineering and Materials
researchProduct

Formation of an interlocked double-chain from an organic-inorganic [2]rotaxane.

2019

Here we show that a structure containing a polymeric interlocking daisy chain is obtained from the reaction of an inorganic–organic [2]rotaxane [HB{CrIII7NiII(μ-F)8(O2CtBu)16}], where B is an organic thread terminated with a bi-pyridyl unit, with an oxo-centered metal carboxylate triangle [FeIII2CoII(μ3-O)(O2CtBu)6(HO2CtBu)3].

Rotaxane010405 organic chemistryChemistryMetals and AlloysGeneral Chemistry010402 general chemistry01 natural sciencesCatalysis0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsDouble chainMetalchemistry.chemical_compoundTheoryofComputation_ANALYSISOFALGORITHMSANDPROBLEMCOMPLEXITYvisual_artPolymer chemistryOrganic inorganicMaterials ChemistryCeramics and Compositesvisual_art.visual_art_mediumCarboxylateDaisy chainChemical communications (Cambridge, England)
researchProduct

Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…

2015

OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…

RoxolidMaleSmall diameterSLActive surfaceDentistrychemistry.chemical_elementMandibleCONVENTIONAL COMPLETE DENTURESlaw.inventionDouble blindRETROSPECTIVE EVALUATION IMPLANTDouble-Blind MethodRandomized controlled triallawMARGINAL BONE LOSSHumansJaw EdentulousMedicineMANDIBULAR 2-IMPLANT OVERDENTURES610 Medicine & healthAgedDental ImplantsTitaniumPATIENT SATISFACTIONTitanium/zirconiumSTRESS-DISTRIBUTIONbusiness.industryDental Implantation Endosseoustechnology industry and agricultureWITHIN-SUBJECT COMPARISONSSoft tissueDIFFERENT LOADING PROTOCOLSDenture Overlayequipment and suppliesTitanium zirconiumddc:617.6Treatment OutcomeDental Prosthesis DesignchemistryImplant typesedentulousFemaleZirconiumImplantFINITE-ELEMENT-ANALYSISOral SurgerybusinessDental AlloysTitaniumClinical Oral Implants Research
researchProduct

Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…

2015

BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …

RoxolidSmall diameterSplit-mouthDentistrychemistry.chemical_element610 Medicine & healthMandiblelaw.inventionTiZrDouble blindstomatognathic systemRandomized controlled trialDouble-Blind MethodlawOverdenturesAlloysMedicineHumansJaw Edentulous610 Medicine & healthGeneral DentistrySurvival rateOrthodonticsDental ImplantsTitaniumbusiness.industryDentistry(all)Ti Grade IVDental Implantation Endosseoustechnology industry and agricultureSLActiveequipment and suppliesDenture OverlayTitanium zirconiumddc:617.6stomatognathic diseaseschemistryDental Prosthesis DesignOral and maxillofacial surgeryImplantZirconiumbusinessTitaniumFollow-Up StudiesResearch Article
researchProduct

Restyling para una nueva etapa

2021

Salud mentalMechanics of MaterialsMechanical EngineeringMetals and AlloysRevista Española de Enfermería de Salud MentalEnfermería
researchProduct

Towards sarcosine determination in urine for prostatic carcinoma detection

2019

Abstract Sarcosine, a potential biomarker for prostate cancer, can be detected in a solid state enzyme based biosensor using sarcosine oxidase, with particle immobilised reagents. A novel fusion protein of the fluorescent protein, mCherry, sarcosine oxidase (SOx), and the polypeptide R5 (R52-mCherry-SOx-R5-6 H), was explored, which allowed self-immobilization on silica microparticles and long-term (90 days +) retention of activity, even at room temperature. In contrast, commercial wildtype SOx lost activity in a few days. A silica-R52-mCherry-SOx-R5-6H microparticle sensor for determination of sarcosine in urine, linked the SOx coproduct, H2O2, to a measurement catalysed by horseradish pero…

Sarcosine02 engineering and technologyUrine010402 general chemistry01 natural sciencesHorseradish peroxidasechemistry.chemical_compoundMaterials ChemistryElectrical and Electronic EngineeringMicroparticleInstrumentationSarcosine oxidasechemistry.chemical_classificationChromatographybiologyMetals and Alloys021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsEnzymechemistrybiology.proteinUric acid0210 nano-technologyBiosensorSensors and Actuators B: Chemical
researchProduct