Search results for "AOC"

showing 10 items of 504 documents

Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry

2021

PURPOSE To analyze the agreement of the predicted intraocular lens (IOL) power obtained with ANTERION, IOLMaster 700 and Pentacam AXL biometers. METHODS We calculated the monofocal and trifocal IOL power using the SRK/T, Haigis, Barrett Universal II and Hoffer Q formulas for 106 eyes. IOL power agreement between devices was evaluated using the Bland-Altman method. RESULTS We found significant differences between biometers comparisons (p  0.05), with the same outcomes for medium- and long-eyes. No significant differences were found using the SRK/T, Haigis, or Hoffer Q formulas for short-eyes (p > 0.1). However, Barrett Universal II formula produced significant differences (p < 0.05) and thes…

Lenses IntraocularPhysicsmedicine.medical_specialtyBiometrymedicine.diagnostic_testmedicine.medical_treatmentLimits of agreementScheimpflug principleBiomedical EngineeringReproducibility of ResultsIntraocular lensGeneral MedicineAxial Length EyeInterferometryOptical coherence tomographyIntraocular lens powerPartial coherence interferometryOphthalmologymedicineHumansOptical biometerSurgeryTomography Optical CoherenceRetrospective StudiesExpert Review of Medical Devices
researchProduct

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

2014

Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…

Lenses IntraocularWavefrontPhysicsOptics and PhotonicsCorneal Wavefront Aberrationbusiness.industryZernike polynomialsAberrometryAstigmatismComa (optics)General MedicineModels TheoreticalOptical qualityOphthalmologyAlcon LaboratoriesSpherical aberrationsymbols.namesakeOpticsLens Implantation IntraocularIntraocular lensesAberrometrysymbolsHumansbusinessEuropean Journal of Ophthalmology
researchProduct

A rapid method for measuring intraocular lens power in vitro with a focimeter.

2015

In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.

Lenses Intraocularmedicine.medical_specialtyOptics and PhotonicsMaterials sciencegenetic structuresmedicine.medical_treatmentReproducibility of ResultsIntraocular lensDiagnostic Techniques Ophthalmologicaleye diseasesSensory Systemslaw.inventionLens (optics)Cellular and Molecular NeuroscienceOphthalmologylawIntraocular lens powerOphthalmologymedicinesense organsExperimental eye research
researchProduct

Incisional Keratotomy to Toric Intraocular Lenses: An Overview of the Correction of Astigmatism in Cataract and Refractive Surgery

2003

Lenses Intraocularmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentAstigmatismCataract ExtractionAstigmatismmedicine.diseasePhotorefractive KeratectomyRefractive Surgical ProceduresCorneaOphthalmologyPostoperative ComplicationsLens Implantation IntraocularIntraocular lensesOphthalmologyRefractive surgerymedicineHumansLasers ExcimerbusinessKeratotomy RadialInternational Ophthalmology Clinics
researchProduct

Semicarbazide-sensitive amine oxidase/vascular adhesion protein-1 deficiency reduces leukocyte infiltration into adipose tissue and favors fat deposi…

2009

1525-2191 (Electronic) Journal Article; Obesity is associated with low-grade inflammation and leukocyte infiltration in white adipose tissue (WAT) and is linked to diabetic complications. Semicarbazide-sensitive amine oxidase, also known as vascular adhesion protein-1 (SSAO/VAP-1), is a membrane protein that is highly expressed in adipocytes and is also present on the endothelial cell surface where it is involved in leukocyte extravasation. We studied fat deposition and leukocyte infiltration in WAT of mice with a null mutation in the amine oxidase copper-containing-3 (AOC3) gene encoding SSAO/VAP-1. Both epididymal and inguinal WATs were larger in 6-month-old AOC3-KO males than in age-matc…

MESH: SemicarbazidesAOC3Obesity/geneticsAdipose tissueMESH: Flow CytometryWhite adipose tissueInbred C57BLMESH: Mice KnockoutTransgenicMiceLeukocytesMESH: ObesityMESH: AnimalsMice KnockoutAmine oxidase (copper-containing)food and beveragesNatural killer T cellFlow CytometryLeukocyte extravasationSemicarbazidesCell Adhesion Molecules/*deficiency/*geneticsAdipose TissueMESH: Cell Adhesion MoleculesLeukocytes/*physiologyAmine Oxidase (Copper-Containing)medicine.symptomInfiltration (medical)MESH: Adipose Tissuemedicine.medical_specialtyMESH: Mice TransgenicKnockoutMice TransgenicInflammation[SDV.BC]Life Sciences [q-bio]/Cellular BiologyBiologyMESH: Monoamine OxidasePathology and Forensic MedicineMESH: LeukocytesMonoamine Oxidase/*deficiencyMESH: Mice Inbred C57BLInternal medicinemedicineAnimalsHumansObesityMonoamine OxidaseMESH: Mice[SDV.BC] Life Sciences [q-bio]/Cellular BiologyMESH: HumansAmine Oxidase (Copper-Containing)/*deficiency/*geneticsmedicine.diseaseAdipose Tissue/pathology/*physiologyMice Inbred C57BLEndocrinologyImmunologyMESH: Amine Oxidase (Copper-Containing)Semicarbazides/*pharmacologyCell Adhesion MoleculesRegular Articles
researchProduct

Effect of Riboflavin/UVA Collagen Cross-linking on Central Cornea, Limbus and Intraocular Pressure. Experimental Study in Rabbit Eyes

2016

The Purpose of present study was to investigate the effect of riboflavin/ultraviolet-A-induced collagen cross-linking (CXL) on central cornea, limbus and intraocular pressure (IOP). This was an animal experimental study. The right corneas of 10 rabbits were ultraviolet-A irradiated (3 mW/cm2 for 30 minutes) after de-epithelialization and instillation of 0.1% riboflavin / 20% Dextran drops. Left corneas served as controls. Samples were examined histologically one month postoperatively. Before and after treatment, IOP measurements were recorded bilaterally. At central cornea of eyes underwent CXL keratocyte repopulation, normal arrangement of collagen fibres and a statistically significant ch…

Male0301 basic medicineIntraocular pressuremedicine.medical_specialtyCollagen cross linkinggenetic structuresUltraviolet RaysIntraocular pressureRiboflavinlcsh:MedicineRiboflavinLimbus CorneaeCornea03 medical and health sciences0302 clinical medicineCollagen fibresOphthalmologyCorneamedicineAnimalsLimbusPhotosensitizing Agentsbusiness.industrylcsh:RSignificant differenceCorneal CrosslinkingGeneral Medicineeye diseasesCross-Linking Reagents030104 developmental biologymedicine.anatomical_structure030221 ophthalmology & optometryCollagenRabbitssense organsCentral corneabusinessAfter treatmentActa Medica (Hradec Kralove, Czech Republic)
researchProduct

Contrast sensitivity and color perception with orange and yellow intraocular lenses

2012

To evaluate contrast sensitivity function (CSF) and color vision after implantation of either orange or yellow-tinted intraocular lenses (IOLs).Fifty-six eyes of 28 cataract patients who had bilateral implantation of orange-tinted (PC440Y Orange, Ophtec), yellow-tinted (AcrySof Natural SN60AT, Alcon), or clear (AcrySof SA60AT, Alcon) IOLs were examined. Six months postoperatively, monocular CSF under photopic and mesopic (with and without glare) conditions were measured using the Functional Visual Analyzer. Color discrimination was determined with the Farnsworth-Munsell 100-Hue test.Patients implanted with orange-tinted, yellow-tinted, or clear IOLs displayed similar CSF values, with no sta…

Male0301 basic medicinemedicine.medical_specialtygenetic structuresColor visionmedicine.medical_treatmentMesopic VisionVisual AcuityOrange (colour)Prosthesis DesignColor discriminationContrast Sensitivity03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOphthalmologyHumansMedicineProsthesis designProspective StudiesAgedLenses IntraocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationeye diseasesOphthalmology030104 developmental biologyIntraocular lenses030221 ophthalmology & optometryFemalesense organsbusinessColor PerceptionEuropean Journal of Ophthalmology
researchProduct

Canaloplasty with mitomycin C after previous combined cataract surgery and Schlemm's canal microstent implantation.

2021

We report on a 56-year-old male with primary open-angle glaucoma who underwent mitomycin C augmented canaloplasty enabling filtration in the right eye after cataract surgery combined with a Schlemm’s canal microstent 3 years previously. He showed progressive glaucomatous optic neuropathy and was highly myopic (axial length 32.05 mm, spherical equivalent −18.75 dioptres in the right eye). Augmented canaloplasty was performed uneventfully and 360° catheterisation was achieved followed by the placement of a 10-0 polypropylene suture in Schlemm’s canal. Intraocular pressure (IOP) in the first post-operative day was reduced from 19 to 6 mmHg. At 1-month follow-up IOP was 12 mmHg off glaucoma me…

Male030213 general clinical medicinemedicine.medical_specialtygenetic structuresOpen angle glaucomamedicine.medical_treatmentMitomycinGlaucomaAfter cataractTrabeculectomyCataract03 medical and health sciences0302 clinical medicineOphthalmologyMedicineHumansIntraocular PressureSchlemm's canalbusiness.industryMitomycin CGeneral MedicineCataract surgeryMiddle Agedmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometrysense organsbusinessGlaucoma Open-AngleEuropean journal of ophthalmology
researchProduct

Intraocular Pressure Telemetry for Managing Glaucoma during the COVID-19 Pandemic

2021

Purpose To evaluate in glaucoma patients the feasibility and use of remote monitoring of intraocular pressure (IOP) with an implanted telemetry sensor during the coronavirus disease 2019 (COVID-19) lockdown. Design Cross-sectional study. Participants Patients previously implanted with a telemetric IOP sensor (Eyemate; Implandata GmbH) were included. Methods Intraocular pressure measurements acquired by the patients during the lockdown were collected by physicians who were located remotely. A questionnaire was sent to 10 participating study centers to evaluate the clinical impact of remote monitoring of IOP via the IOP sensor system. Main Outcome Measures Number of patients who obtained home…

MaleAgingIntraocular pressuregenetic structuresCross-sectional studyIntraocular pressureOffice visitsGlaucomaComorbidityNeurodegenerative01 natural sciences0302 clinical medicineTelemetryTelemetryProspective StudiesProspective cohort studyCOVID-19 coronavirus disease 2019Sensor systemInfectiousGeneral MedicineEquipment DesignMiddle AgedFemaleSwitzerlandmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)MonitoringClinical Trials and Supportive ActivitiesBioengineeringTonometry03 medical and health sciencesTonometry OcularDisease TransmissionClinical ResearchOcularOphthalmologyLockdownmedicineDisease Transmission InfectiousHumans0101 mathematicsEye Disease and Disorders of VisionPandemicsbusiness.industrySARS-CoV-2IOP010102 general mathematicsNeurosciencesCOVID-19Glaucomamedicine.diseaseIOP intraocular pressureeye diseasesFull-length articles and Review articlesUnited KingdomCross-Sectional Studies030221 ophthalmology & optometrysense organsbusinessFollow-Up StudiesOphthalmology. Glaucoma
researchProduct

Suture Removal After Trabeculectomy With Fornix-based Conjunctival Flap Leads to Faster Visual Recovery but Not Reduced Astigmatism

2019

PReCIS:: The closing limbal suture after trabeculectomy with a fornix-based conjunctival flap plays no critical role in the development of corneal astigmatism and intraocular pressure (IOP). A standard removal is not recommended. Purpose To investigate the effect of removal of the conjunctival suture after trabeculectomy with fornix-based conjunctival flap on corneal astigmatism, visual acuity, and IOP. Methods Eighty-seven cases of trabeculectomy with mitomycin C with a fornix-based conjunctival flap performed in the eyes of 82 patients (5 patients underwent bilateral trabeculectomy) were enrolled in a prospective randomized study. All surgeries were conducted by the same surgeon (J.W.) in…

MaleAlkylating AgentsIntraocular pressuremedicine.medical_specialtyVisual acuitygenetic structuresMitomycinmedicine.medical_treatmentVisual AcuityGlaucomaTrabeculectomyAstigmatismSurgical FlapsTonometry Ocular03 medical and health sciences0302 clinical medicineSuture (anatomy)OphthalmologymedicineHumansTrabeculectomyProspective StudiesIntraocular PressureAgedmedicine.diagnostic_testbusiness.industrySuture TechniquesFornixAstigmatismRecovery of FunctionMiddle AgedCorneal topographymedicine.diseaseeye diseasesOphthalmology030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessConjunctivaGlaucoma Open-Angle030217 neurology & neurosurgeryFollow-Up StudiesJournal of Glaucoma
researchProduct