Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
2011
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…
Eye Movement Involvement in Parry-Romberg Syndrome: A Clinicopathologic Case Report
2008
We report the case of a 38-year-old woman who developed a progressive bilateral disease in which the eye motility disorder-diplopia-is the outstanding feature over a period of 12 years. The muscle biopsy of the medial rectus muscle did not show any trace of striated muscle. To the best of our knowledge, this is the first pathological report in an affected extraocular muscle of a patient with Parry-Romberg syndrome (PRS). Previous rare reports of diplopia in PRS have been attributed to enophthalmos, progressive atrophy of the orbit, ocular motor nerve dysfunction, or mechanical restrictions.
Effects of Early Postfiltration Ocular Hypotony on Visual Acuity, Long-term Intraocular Pressure Control, and Posterior Segment Morphology
2001
Purpose To determine whether hypotony after filtration surgery has any influence on visual acuity and intraocular pressure (IOP) lowering. Patients and methods We prospectively investigated 43 eyes of 43 patients undergoing trabeculectomy without the use of antimetabolites for 12 months. Results The lowest postoperative IOP valued 4.9 +/- 3.6 mm Hg (range, 0-14 mm Hg). It correlated statistically significant with the IOP 6 weeks (P = 0.016), 6 months (P = 0.009), and 1 year after surgery (P = 0.027). Eyes with a deterioration of visual acuity 6 weeks after surgery had undergone a stronger postoperative hypotony (correlation with lowest postoperative IOP, P = 0.035). The mean period with an …
Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation
2000
BACKGROUND—Standard examination of contrast sensitivity under conditions of glare disability is performed with incandescent light. A new halogen glare test that simulates glare as seen with oncoming vehicle headlights was used to measure glare disability in patients implanted with multifocal and monofocal intraocular lenses (IOLs). METHODS—28 patients with an average age of 69 years (SD 12 years) were implanted with a monofocal IOL (SI-40NB, Allergan) and 28 patients with an average of 66 years (12 years) were implanted with a refractive multifocal IOL (Array-SA-40N, Allergan). All patients were followed for 5 months postoperatively. Contrast sensitivity at four spatial frequencies (3, 6, 1…
Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields
1996
Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects
2006
To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…
The relationship between central corneal thickness and Goldmann applanation tonometry
2003
The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…