Search results for "AOC"

showing 10 items of 504 documents

Ocular Motor Palsy After Spinal Puncture

2017

Abstract Ocular motor palsy is a rare but alarming complication of subarachnoid puncture. In order to better understand this condition, a literature search was performed in English of PubMed articles for cranial nerves III, IV, and VI palsies after spinal puncture. Sixty-five articles (dated 1930–2015) were identified, and 114 cases were obtained for analysis. Subarachnoid anesthesia was the most frequent cause (45.6%), with a higher incidence for females than males. The age of patients was 40.24 ± 13.35 years (age range, 6–71 years). The sixth cranial nerve was the most commonly involved (92.1%), with higher frequency in the right eye. Palsy onset started 7.30 ± 4.09 days after puncture. D…

medicine.medical_specialtyPalsybusiness.industryOcular motorIncidence (epidemiology)Cranial nervesGeneral MedicineExtraocular musclesSurgery03 medical and health sciencesAnesthesiology and Pain Medicinemedicine.anatomical_structure0302 clinical medicineSpinal PunctureFluid therapy030202 anesthesiologyAnesthesia030221 ophthalmology & optometryMedicineComplicationbusiness030217 neurology & neurosurgerySurvey of Anesthesiology
researchProduct

<p>Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens</p>

2019

Purpose To assess visual and refractive results after bilateral implantation of a trifocal intraocular lens (IOL) in patients with hyperopia. Methods In a retrospective nonrandomized study, 196 eyes of 98 patients had bilateral implantation of a trifocal IOL. The Barrett Universal II formula was used for IOL power calculation. Eyes were divided into two groups for their analysis: low-moderate, with IOL power ranging from 22 to 26 D, and high, with IOL power ranging from 25 to 34 D. Refractive error was used to assess predictability, and corrected distance visual acuity (CDVA) and uncorrected distance visual acuity values were used to assess efficacy and safety of the surgery. Results Six mo…

medicine.medical_specialtyRefractive errorDistance visual acuityVisual acuitygenetic structuresbusiness.industrymedicine.medical_treatmentSpherical equivalentIntraocular lensPhacoemulsificationmedicine.diseaseeye diseases03 medical and health sciencesOphthalmology0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicineIn patientsense organsmedicine.symptombusiness030217 neurology & neurosurgeryClinical Ophthalmology
researchProduct

Ergebnisse nach Implantation einer Worst Iris Claw Lens zur Korrektur der hohen Myopie

2001

Fragestellung. Ziel dieser prospektiven klinischen Studie war die Erfassung der Refraktion, des korrigierten Visus und des Vorderkammerreizzustandes nach Implantation einer Worst Iris Claw Lens zur Korrektur der hohen Myopie. Patienten und Methode. Von Dezember 1996 bis Februar 1999 wurde bei insgesamt 44 phaken Augen von 28 Patienten eine Worst Iris Claw Lens implantiert. Es folgte eine Nachbeobachtungszeit von 6 Wochen bzw. 6 Monaten. Ergebnisse. Das mittlere praoperative spharische Aquivalent betrug −17,35±3,57 dpt. Sechs Monate postoperativ lag die Refraktion bei 79% der Augen im Intervall von ±1,0 dpt von der Zielrefraktion entfernt. Der mittlere korrigierte Visus stieg von praoperativ…

medicine.medical_specialtyRefractive errorPolymethyl methacrylatebusiness.industrymedicine.medical_treatmentFollow up studiesIntraocular lensOcular refractionmedicine.diseaseVision disorderOphthalmologyOphthalmologymedicineProsthesis designmedicine.symptombusinessDer Ophthalmologe
researchProduct

Toric phakic intraocular lens

2003

Abstract Objective To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism. Design Prospective, nonrandomized, comparative (self-controlled) multicenter trial. Participants Seventy eyes of 53 patients (mean, 35 years; range, 22–59 years) with preoperative spherical equivalent between +6.50 and −21.25 diopters (D) and cylinder between 1.50 and 7.25 D. Methods Seventy eyes underwent implantation of a TPIOL with an optical zone of 5.0 mm (Artisan, Ophtec, Groningen, The Netherlands). The dioptric power of the intraocular lens…

medicine.medical_specialtyRefractive errorVisual acuitygenetic structuresKeratometerbusiness.industrymedicine.medical_treatmentIntraocular lensAstigmatismmedicine.diseasePhakic intraocular lenseye diseaseslaw.inventionToric lensOphthalmologylawOphthalmologymedicinesense organsmedicine.symptombusinessDioptreOphthalmology
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Patient and ophthalmologist attitudes concerning compliance and dosing in glaucoma treatment.

2005

The aim of this study was to identify research avenues that might improve patient compliance with glaucoma therapy.500 patients and physicians were interviewed by telephone in 5 European countries, and the results were compiled and evaluated by 2 independent physicians.Most physicians believed that pressure reduction is useful (UK (96%), France (94%), Spain (80%), Italy (72%), and Germany (70%), p0.0001). The majority of physicians believed that noncompliance exists in 0%-25% of patients, whereas 34% of patients admitted to noncompliance. Physicians believed patients would prefer once-daily dosing (92%) and that it would help compliance, whereas 60% of patients preferred once-daily dosing, …

medicine.medical_specialtyTime FactorsVisual impairmentGlaucomaDrug complianceCompliance (psychology)Patient Education as TopicmedicineHumansPharmacology (medical)DosingPatient complianceRoyaume uniIntraocular PressurePharmacologyPressure reductionPhysician-Patient Relationsbusiness.industryData CollectionGlaucomamedicine.diseaseSurgeryEuropeOphthalmologyEmergency medicinePatient Compliancemedicine.symptomOphthalmic SolutionsbusinessAttitude to HealthJournal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics
researchProduct

Descemet Membrane Endothelial Keratoplasty for Corneal Decompensation Secondary to Phakic Intraocular Lenses

2019

Purpose. To describe the surgical technique and clinical outcomes of bilensectomy (pIOL explant and phacoemulsification), followed by DMEK performed for bullous keratopathy secondary to pIOL.Methods. Seven eyes of seven patients, who developed corneal decompensation after pIOL implantation, underwent bilensectomy followed by DMEK in a two-step procedure. Main outcome measures included uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), refraction, endothelial cell density (ECD) at 1, 3, 6, and 12 months, and intraoperative and postoperative complications.Results. DMEK was performed at a mean time of 9.83 ± 8.23 months after bilensectomy. BCVA (log MAR) improved in all …

medicine.medical_specialtyVisual acuityDescemet membraneCorneal Decompensationgenetic structuresArticle Subjectbusiness.industrymedicine.medical_treatmentUncorrected visual acuityPhacoemulsificationPhakic intraocular lenseye diseasesOphthalmologylcsh:Ophthalmologylcsh:RE1-994OphthalmologyBullous keratopathymedicinePrimary graft failuremedicine.symptombusinessResearch ArticleJournal of Ophthalmology
researchProduct

ATD perimetry in glaucoma and ocular hypertensive patients. A preliminar study

2007

Purpose: The new ATD perimetry assesses contrast sentivity thresholds for the three afferent sensory pathways of the visual system. Our aim is to compare contrast sensitivity to stimuli with different spatio-temporal frequencies in glaucomatous (G) and ocular hypertensive (OHT) subjects. Methods: Twenty three G and OHT subjects were selected from the ophthalmic clinic, all subjects signed an informed consent. Inclusion criteria were diagnosis of G or OHT, normal Farnsworth-Munsell color test, ametropia less than 6 D, visual acuity over 20/30, absence of previous ocular surgery and experience in perimetry. Twenty locations and the fovea were evaluated in a 60o x 40o fovea-centered field. Eig…

medicine.medical_specialtyVisual acuitybusiness.industryOcular surgeryColor testGlaucomamedicine.diseaseOphthalmologyAfferentOphthalmologymedicineStatistical analysisAnalysis of variancemedicine.symptomHigh intraocular pressurebusinessActa Ophthalmologica Scandinavica
researchProduct

Reading ability with 3 multifocal intraocular lens models.

2006

Purpose To prospectively evaluate reading performance with of 3 types of multifocal intraocular lenses (IOLs) under different lighting conditions based on reading acuity and reading speed tests. Setting Augenklinik, Bad Hersfeld, Germany. Methods This randomized study comprised 60 cataract patients (120 eyes) randomly assigned to receive an SA40N IOL (AMO) (Group 1, 20 patients), Tecnis ZM001 IOL (AMO) (Group 2, 20 patients), or AcrySof ReSTOR SA60D3 IOL (Alcon) (Group 3, 20 patients). Pupil size and reading ability at near (visual acuity, reading speed) without correction, with best distance correction, and with best near correction were assessed 6 weeks postoperatively under low-light con…

medicine.medical_specialtyVisual acuitygenetic structuresLightPseudophakiamedicine.medical_treatmentmedia_common.quotation_subjectEye diseaseVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularOphthalmologyReading (process)medicineHumansProspective Studiesmedia_commonLenses IntraocularPhacoemulsificationbusiness.industrySignificant differencePupil sizePupilMultifocal intraocular lensMiddle Agedmedicine.diseaseDistance correctioneye diseasesSensory SystemsOphthalmologyReadingOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

The Impact on Vision of Aspheric to Spherical Monofocal Intraocular Lenses in Cataract Surgery

2013

Purpose To provide a summary of the impact on vision of an aspheric intraocular lens (IOL) compared with a spherical IOL in cataract surgery. Design Systematic review with meta-analysis. Participants Patients from published randomized controlled trials (RCTs) of cataract surgery with aspheric compared with spherical monofocal IOL implantation. Methods We systematically searched the peer-reviewed literature in MEDLINE, EMBASE, Web of Science, BIOSIS, and the Cochrane Library according to the Cochrane Collaboration method to identify relevant RCTs. The inclusion criteria were RCTs on cataract surgery comparing the use of aspheric versus spherical IOL implantation that assessed visual acuity, …

medicine.medical_specialtyVisual acuitygenetic structuresbusiness.industryMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensCochrane LibraryCataract surgeryeye diseasesOphthalmologyMeta-analysisOphthalmologyContrast (vision)MedicineOptometrysense organsmedicine.symptombusinessmedia_commonPhotopic visionOphthalmology
researchProduct