Search results for "AREs"

showing 10 items of 1717 documents

Direct determination of minerals in human diets by infrared spectroscopy and X-ray fluorescence

2014

The use of near and mid infrared spectroscopy and X-ray fluorescence (XRF) to determine the concentration of mineral elements in Spanish human diets was investigated. Thirty-five commercial baby foods, 6 children fast food menus and 13 university canteen menu samples were analysed by infrared and XRF spectroscopy and spectra evaluated by using reference data obtained by inductively coupled plasma optical emission spectroscopy (ICP-OES). Models for calcium, potassium, iron, magnesium, sodium and zinc determination were built and validated. Spectra were pre-treated by using different pre-processing algorithms (multiplicative scatter correction, standard normal variation, first derivate, ortho…

ChemistryInfraredPotassiumPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopychemistry.chemical_elementX-ray fluorescenceInductively coupled plasmaSpectroscopySpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct

Evaluation of infrared spectroscopy as a screening tool for serum analysis

2013

Abstract The application of attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy to the determination of clinical parameters in serum using partial least squares (PLS) has been evaluated as a point-of-care diagnostic tool. In this study the effect of using an increased size of the calibration set and the influence of the origin of samples and their interyear variation on the prediction capability of the method were considered. PLS-ATR-FT-IR provides a green, fast and cheap point-of-care tool for the determination of total protein. Albumin, glucose, urea, HDL, LDL and total cholesterol were predicted with relative errors between 15 and 32%. The analytical predicti…

ChemometricsAnalyteStandard errorChemistryCalibration (statistics)Attenuated total reflectionPrincipal component analysisPartial least squares regressionStatisticsSample (statistics)SpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct

Multivariate data analysis and bivariate regression studies applied to comparison of two multi-elemental methods for analysing wine samples

2002

Two inductively coupled plasma mass spectrometry (ICP-MS) methods which permit multi-elemental analysis in wine samples have been compared following two strategies. First, a multivariate tool based on principal component analysis (PCA) was employed for a global (all analytes) qualitative comparison of the two methods. A single plot based on the confidence limits of the Q and T2 PCA model statistics corresponding to the ‘standard’ method results (calibration set) was used to check the comparability of the ‘candidate’ method (test samples). The residual matrix (after test matrix interpolation into the PCA model) gives qualitative information about the nature of the main errors. This approach …

ChemometricsMultivariate statisticsApplied MathematicsPrincipal component analysisStatisticsLinear regressionEconometricsBivariate analysisMissing dataLeast squaresAnalytical ChemistryMathematicsInterpolationJournal of Chemometrics
researchProduct

Quantitative determination of surface area of silica gel particles by near infrared spectroscopy and chemometrics

2008

Abstract Surface areas of silica gel particles have been quantitatively determined by using near infrared spectrometry and chemometrics. Surface areas of six silica gel samples with varying surface area (300–750 m2/g) have been determined by the common Brunauer–Emmett–Teller (BET) method and used in preparing mixtures of silica gel samples with varying surface area in the ranges 300–474 and 500–750 m2/g. The near infrared spectra of the mixtures were measured and the spectral profiles calibrated against the calculated surface area of the mixtures as dependent variable using partial least squares (PLS) technique. The models obtained from the calibrations were then used in predicting the surf…

Chemometricschemistry.chemical_compoundColloid and Surface ChemistryChemistrySilica gelNear-infrared spectroscopyPartial least squares regressionAnalytical chemistryCalibrationParticleInfrared spectroscopyBET theoryColloids and Surfaces A: Physicochemical and Engineering Aspects
researchProduct

Partial least squares attenuated total reflectance IR spectroscopy versus chromatography: the greener method

2012

Method election is a complex task that must be done carefully in order to ensure the capability of analytical methodologies to provide appropriate data for problem solving. This is a real challenge in all fields, but especially with bioanalysis, which in many cases involves the need to do a large number of determinations in complex

ChromatographyBioanalysisChromatographyChemistryClinical BiochemistryInfrared spectroscopyGreen Chemistry TechnologyGeneral MedicineAnalytical ChemistryMedical Laboratory TechnologyAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionLeast-Squares AnalysisGeneral Pharmacology Toxicology and PharmaceuticsBioanalysis
researchProduct

Determination of critical eluent composition for polyethylenglycols using on-line liquid chromatography-Fourier transform infrared spectrometry.

2008

In this work, it has been extended to methanol:water mobile phases, the use of a background correction method for on-line LC-FTIR measurements named Univariate background correction based on the use of a reference spectra matrix (UBC-RSM) and absorbance ratios. It permits to overcome the problem related to spectral changes occurring during the gradient elution, which in the past limited the on-line coupling of LC and FTIR to isocratic elutions. The combined use of the aforementioned background correction technique in on-line isocratic and gradient LC-FTIR, and partial least squares (PLS) has been applied for the search of the critical conditions for polymers. Polyethylenglycol (PEG) has bee…

ChromatographyChemistryAnalytical chemistryInfrared spectroscopyBiochemistryFourier transform spectroscopyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceColumn chromatographyPartial least squares regressionEnvironmental ChemistryBackground Correction MethodFourier transform infrared spectroscopySpectroscopy
researchProduct

Direct determination of Mancozeb by photoacoustic spectrometry

2006

Abstract A solvent free, fast and environmentally friendly photoacoustic-infrared-based methodology (PAS-FTIR) was developed for the determination of Mancozeb in agrochemicals. This methodology was based on the direct measurement of the transmittance spectra of solid samples and a multivariate calibration model to determine the active ingredient concentration. The proposed partial least squares (PLS) model was made using nine standards prepared by mixing different amounts of kaolin and Mancozeb, with concentrations between 5.43 and 88.10% (w/w). A hierarchical cluster analysis was made in order to classify the samples in terms of similarity in the PAS-FTIR spectra. From their spectra differ…

ChromatographyChemistryDirect methodAnalytical chemistryPhotoacoustic imaging in biomedicineMass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundPartial least squares regressionCalibrationEnvironmental ChemistryMancozebSample preparationMetalaxylSpectroscopyAnalytica Chimica Acta
researchProduct

Prediction of wheat dough W and P/L inflation test parameters by capillary zone electrophoresis of a protein extract followed by multivariate regress…

2004

A procedure for the evaluation of the wheat flour hardness, based on capillary electrophoresis of a protein extract in an isoelectric acidic buffer, was developed. The 13 flour samples were extracted twice, and two injections of each extract were made. Separations were performed in a background electrolyte (BGE) containing 40 mM aspartic acid, 6 M urea, and 0.5% hydroxyethylcellulose at 60 degrees C. Using the normalized and corrected areas of 79 peaks and peak groups, a partial least squares regression (PLS1) model was able to predict the flour strength or dough deformation work (W) and the dough tenacity/extensibility ratio (P/L) (Alveograph parameters) with an average relative standard d…

ChromatographyChemistryfungiClinical BiochemistryWheat flourAnalytical chemistryfood and beveragesElectrophoresis CapillaryRegression analysisBreadBiochemistryAnalytical ChemistryElectrophoresischemistry.chemical_compoundIsoelectric pointCapillary electrophoresisPartial least squares regressionLinear regressionMultivariate AnalysisUreaRegression AnalysisIndicators and ReagentsTriticumPlant ProteinsElectrophoresis
researchProduct

Determination of cow's milk and ripening time in nonbovine cheese by capillary electrophoresis of the ethanol-water protein fraction

2000

A novel method is reported for analyzing adulteration of goat and ewe cheeses with cow's milk: capillary zone electrophoresis (CZE) in isoelectric, acidic buffers (50 mM imino diacetic acid, IDA, pH = pI 2.3). The cheese samples were extracted with a 20:80 v/v ethanol-water mixture in presence of 3 M urea and 1% beta-mercaptoethanol for 1 h. After centrifugation and lipid extraction, the samples were dissolved in 50 mM IDA, 6 M urea and 0.5% hydroxyethyl cellulose and analyzed by CZE at 700 V/cm. A total of 18 characteristic peaks were resolved among the three types of cheeses and 18 variables were defined as their respective areas. There was excellent similarity among the electrophoretic p…

ChromatographyClinical BiochemistryCheese ripeningRipeningBiochemistryAnalytical ChemistryElectrophoresischemistry.chemical_compoundIsoelectric pointCapillary electrophoresischemistryPartial least squares regressionUreaFood scienceHydroxyethyl celluloseElectrophoresis
researchProduct

Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.

2007

The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…

ChromatographyDiffuse reflectance infrared fourier transformChemistryAttenuated total reflectionDirect methodPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopyFourier transform infrared spectroscopyFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct