Search results for "ARIA"
showing 10 items of 17848 documents
District heating networks: enhancement of the efficiency
2019
International audience; During the decades the district heating's (DH) advantages (more cost-efficient heat generation and reduced air pollution) overcompensated the additional costs of transmission and distribution of the centrally produced thermal energy to consumers. Rapid increase in the efficiency of low-power heaters, development of separated low heat density areas in cities reduce the competitiveness of the large centralized DH systems in comparison with the distributed cluster-size networks and even local heating. Reduction of transmission costs, enhancement of the network efficiency by optimization of the design of the DH networks become a critical issue. The methodology for determ…
Bleaching efficacy of at home 16% carbamide peroxide. A long-term clinical follow-up study.
2019
OBJECTIVE To assess the whitening efficacy of a 16% carbamide peroxidase (CP) gel after 42 months of clinical follow-up. MATERIALS AND METHODS A retrospective clinical study was carried out involving 95 participants. CP 16% was applied for 90 minutes a day for 4 weeks using individualized trays. Tooth color was assessed using spectrophotometry at baseline, 1 week after the end of treatment, and every 6 months until completing 42 months of follow-up. Color parameters were compared using analysis of variance for repeated measures. The analysis by teeth groups was performed using two-way ANOVA. RESULTS The mean baseline L* was 81.7 ± 5.2 versus 83.6 ± 8.8 after 42 months (P<.01). L* showed a d…
Comments on “Overflow characteristics of streamlined weirs based on model experimentation” by Bagheri S. and Kabiri-Samani A
2021
Abstract In this paper the stage-discharge equation of a streamlined weir is theoretically deduced applying the Π-Theorem of dimensional analysis and the self-similarity theory. The coefficients of the new stage-discharge relationship are estimated using the experimental results by Bagheri and Kabiri-Samani.
Linking the Kinetic Energy Fraction and Equivalent Length Method for Trickle Irrigation Design under Local Losses
2020
New methods using analytical relationships to design drip irrigation laterals and subunits have been introduced in recent years based on the assumption that minor losses can be neglected. This assumption could be relaxed by applying the equivalent method, which makes it possible to account for minor losses, such as those caused by emitter connections, through formulas based on the rationale that an equivalent length of the drip lateral produces the same losses. However, equivalent length formulas are empirical; thus, they do not necessarily cover the entire range of conditions in the real-world contexts in which the formulas will be applied, and their extrapolation could lead to erroneous r…
Experimental study and numerical simulation of inclined rectangular weirs
2018
Inclined rectangular weirs, also named pivot weirs, are used both to adjust the upstream water level and to increase the flow capacity compared with that of normal rectangular weirs. However, the experimental studies available in the literature present contradictory conclusions for the inclined weir discharge capacity. In this paper, new experimental runs and numerical simulations were performed to investigate the effect of the rectangular weir inclination angle on the stage-discharge formula. The experiments were carried out using inclination angles ranging from 30° to 90°. Buckingham's theorem of dimensional analysis was used to obtain an equation for the flow magnification ratio (the dis…
Flow measurement using circular portable flume
2018
Abstract The circular portable flume is a simple device to measure discharge in circular drainage networks. Since the unit can be easily installed and removed, it is helpful in water distribution measurement and management. First in this paper the available studies are reviewed for highlighting the effect of both the contraction ratio and the flume slope on the stage-discharge relationship. Then the Buckingham's Theorem of the dimensional analysis and the self-similarity theory are used to deduce the stage-discharge curve of the circular flume. The new theoretical stage-discharge equation is calibrated by the literature available experimental data and those obtained in this experimental inv…
A comprehensive comparison between halophilic granular and flocculent sludge in withstanding short and long-term salinity fluctuations
2018
The effects of salinity fluctuations on the activity of autochthonous halophilic bacteria in aerobic granular sludge (AGS) and flocculent activated sludge (FAS) reactors were investigated. The response of nitrifiers and denitrifiers activity to drastic and moderate salinity shocks in the short-term (ST) and long-term (LT) was examined. The BOD5removal efficiency decreased only in the reactors subjected to the drastic LT salinity increase. Nevertheless, stable performances were achieved 18 days after the shock in the AGS-R1 (90%), whereas after 27 days in the FAS-R1 (82%). The loss in nitritation efficiency was higher in the FAS reactors and was proportional to the shock intensity. Nitritati…
Testing soil water repellency in a Sicilian area two years after a fire
2019
The water drop penetration time (WDPT) technique was applied in 2018 to check persistence of soil water repellency (SWR) in a Sicilian mountain area affected by a wildfire on June 2016. A total of four sites, that were severely water repellent immediately after burning, were sampled. Depending on the site, wettable soil conditions, less SWR and maintenance of a noticeable SWR were detected two years later. At the site showing a near-constant SWR, WDPTs were particularly high in the top soil layer (0-0.03 m) and they appreciably decreased more in depth. Signs of decreasing SWR in drier soil conditions and in association with coarser soil particles were also detected at this site. High gradie…
Waste activated sludge dewaterability: comparative evaluation of sludge derived from CAS and MBR systems
2016
Nowadays, sludge dewatering is one of the greatest operational cost to wastewater treatment cycle. Specifically, 1t of fresh sludge to be disposed is composed, on average, by 0.25 - 0.30t of suspended solids, with an average cost for treatment and disposal around 280 - 470 €/t of suspended solids. Despite several technologies have been developed with the focus to reduce also the specific sludge production, still mechanical dewatering represents a crucial step to limit the amount of sludge to be disposed. Many physical–chemical parameters influence the sludge dewaterability: floc structure, particle size, bound water content, surface charge and hydrophobicity, Extracellular Polymeric Substan…
The role of extracellular polymeric substances on aerobic granulation with stepwise increase of salinity
2018
Abstract A granular sequencing batch reactor (GSBR) worked for 164 days to study the effect of salinity on aerobic granulation. The feeding had an organic loading rate (OLR) of 1.6 kg COD⋅m −3 ⋅d −1 and a gradual increase of salinity (from 0.30 to 38 g NaCl − ⋅L −1 ) to promote a biological salt-adaptation. First aggregates (average diameter ≈ 0.4 mm) appeared after 14 days. Extracellular polymeric substances (EPSs) analyses revealed that proteins were mainly higher than polysaccharides, and microorganisms metabolized EPSs as additional carbon source, mostly in feast phase, to face the energy demand for salinity adaptation. No significant worsening of organic matter removal was observed. Th…