Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.
2012
Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…
The effect of aberrations on objectively assessed image quality and depth of focus
2017
The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…
Optical factors influencing the amplitude of accommodation
2017
AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
2013
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery
2013
To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…
Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens
2011
PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…
On-eye optical quality of daily disposable contact lenses for different wearing times
2012
Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…
Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas.
2015
To evaluate the visual quality results of fitting a corneoscleral contact lens with multiaspheric geometry design (MAGD CScL) in subjects with irregular corneas after laser-assisted in situ keratomileusis (LASIK) surgery.From a database of patients evaluated for scleral contact lenses, we identified those with irregular corneas and visual problems after they underwent LASIK surgery for correcting myopia. They manifested unsatisfactory visual quality with their current contact lenses or glasses. Therefore, a MAGD CScL was fitted and monitored according to standardized fitting methodology. A diagnostic trial set was used in the fitting process. Visual acuity (VA), subjective visual quality (S…
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…