Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis

2015

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…

AdultVisual acuityCorneal Wavefront AberrationSmartphone/utilizaçãogenetic structuresVisual AcuityComputadores de mão/utilizaçãoStimulus (physiology)Refraction Ocular01 natural sciencesNear visual acuity010309 optics03 medical and health sciences0302 clinical medicinelcsh:Ophthalmology0103 physical sciencesAberrometrymedicineHumansWavefrontbusiness.industryAberrometryComputadores/utilizaçãoGeneral MedicineAmplitude of accommodationOphthalmologySpherical aberrationAcomodação ocularlcsh:RE1-994Accommodation ocular030221 ophthalmology & optometryOptometrySmartphonemedicine.symptombusinessPsychologyAccommodationCell PhoneComputers handheld
researchProduct

The effect of simulated normal and amblyopic higher-order aberrations on visual performance.

2012

Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …

Adultmedicine.medical_specialtyVisual acuityCorneal Wavefront Aberrationgenetic structuresmedia_common.quotation_subjectVisual AcuityAmblyopiaPupilContrast SensitivityYoung AdultOphthalmologyOptical transfer functionmedicineContrast (vision)Humansmedia_commonContrast levelbusiness.industryAberrometryPupil sizeAstigmatismPupilModels TheoreticalRefractive Errorseye diseasesOphthalmologyAberrations of the eyePediatrics Perinatology and Child HealthOptometrysense organsSpatial frequencymedicine.symptombusinessJournal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

Visual quality with corneo-scleral contact lenses for keratoconus management

2018

Purpose: To assess the visual quality achieved by fitting corneo-scleral contact lenses (CScL) for keratoconus management. Methods: Thirty patients with keratoconus presented to have CScL fitted because of the unsatisfactory visual quality they experienced with their contact lenses or spectacles. The eye examination included visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelialcell count, contrast sensitivity and aberrometry. The fitting process was performed using a diagnostic trial set. Subjective visual quality and comfort, and contact lens wear time were also reported. Patients were monitored for one year. Results: Thr…

Keratoconusmedicine.medical_specialtyVisual acuityCorneal ectasiagenetic structuresmedia_common.quotation_subjectKeratoconus03 medical and health sciences0302 clinical medicineOphthalmologyAberrometrymedicineContrast (vision)In patientmedia_commonmedicine.diagnostic_testbusiness.industryMean ageCorneoscleral contact lensGeneral Medicinemedicine.diseaseeye diseasesContact lensOphthalmologyEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryOptometry
researchProduct

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

2014

Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…

Lenses IntraocularWavefrontPhysicsOptics and PhotonicsCorneal Wavefront Aberrationbusiness.industryZernike polynomialsAberrometryAstigmatismComa (optics)General MedicineModels TheoreticalOptical qualityOphthalmologyAlcon LaboratoriesSpherical aberrationsymbols.namesakeOpticsLens Implantation IntraocularIntraocular lensesAberrometrysymbolsHumansbusinessEuropean Journal of Ophthalmology
researchProduct

Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.

2019

To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…

MaleCorneal Wavefront AberrationPseudophakiaMesopic visionZernike polynomialsmedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPupillaw.inventionsymbols.namesakeLens Implantation IntraocularlawmedicineHumansProspective StudiesRetinoscopyMathematicsAgedPhacoemulsificationmedicine.diagnostic_testKeratometerAberrometryMiddle AgedMultifocal Intraocular LensesSensory SystemsOphthalmologyAutorefractorsymbolsOptometrySurgeryFemalePhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management

2019

Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…

MaleCorneal Wavefront AberrationVisual acuitygenetic structuresVisual Acuity0302 clinical medicineIntracorneal ring segmentProsthesis FittingContrast (vision)media_commonmedicine.diagnostic_testQuality assessmentCorneoscleral contact lensProstheses and ImplantsGeneral MedicineMiddle AgedRefractive ErrorsEye examinationFemalemedicine.symptomScleraAdultmedicine.medical_specialtyKeratoconusCorneal ectasiaContact LensesCorneal Stromamedia_common.quotation_subjectKeratoconusContrast SensitivityProsthesis ImplantationYoung Adult03 medical and health sciencesOphthalmologyAberrometrymedicineHumansIntracorneal ring segmentbusiness.industryAberrometryCorneal Topographymedicine.diseaseeye diseasesContact lensOphthalmology030221 ophthalmology & optometrysense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Changes in the objective amplitude of accommodation with pupil size.

2014

PURPOSE We evaluate the effect of pupil size on objectively measured amplitude of accommodation (AA). METHODS Pupil diameter and wavefront aberrometry were obtained in 15 eyes when stimulus swept across the range of clear vision in steps of 0.5 diopters. Wavefront refraction techniques were used to compute objective AA as the maximum refractive change. Measurements were obtained monocularly under low and high ambient room lighting conditions with a fixed luminance of the fixation target. Amplitude of accommodation computations were performed taking into account just paraxial rays (paraxial AA) or including the effects of the change of spherical aberration during accommodation (minRMS AA). R…

MiosisAdultMaleCorneal Wavefront AberrationLightRefraction OcularLuminancePupilCorneaYoung AdultOpticsmedicineHumansDioptrePhysicsbusiness.industryAberrometryParaxial approximationAccommodation OcularPupilAmplitude of accommodationOphthalmologySpherical aberrationFemalemedicine.symptombusinessAccommodationOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Validation of a method for measuring the retinal thickness with Shack–Hartmann aberrometry in an artificial eye

2015

In Shack–Hartmann aberrometry, it is assumed that a wave front emerges from a single point focused on a retina. However, the retina is a multi-layered structure and reflections may occur from several layers. This may result in several overlapping spot patterns on the CCD due to different vergences of the outgoing wave fronts. The amount by which these spot patterns are displaced may contain information about the retinal thickness. In this study, we perform simulations of formation of double spots in a living eye and also apply this method to measure the thickness of an artificial retina with a simple structure. We also compare the results obtained with artificial eye and compare them to the…

PhysicsWavefrontRetinabusiness.industryRetinalLensletAtomic and Molecular Physics and Opticschemistry.chemical_compoundOpticsmedicine.anatomical_structurechemistrySimulated dataAberrometrymedicinesense organsSingle pointbusinessJournal of Modern Optics
researchProduct