Search results for "Absorbance"
showing 10 items of 192 documents
Evaluation and elimination of the blank bias error using the H-point standard additions method (HPSAM) in the simultaneous spectrophotometric determi…
1997
Abstract The aim of this report is to demonstrate the usefulness of the HPSAM in all instances where the determination of two analytes requires the use of an absorbent reagent, particularly when it does not present a constant analytical signal because of its consumption. This problem can be treated as a ternary mixture by the HPSAM method and then, the fundamentals of the method for resolving these kind of mixtures can be applied. The method can calculate the concentration of one species from spectral data at two wavelengths where the two other species present the same absorbance relationship. These wavelength pairs are easily found, and can be selected to give the most precise results. The…
Identification and determination of synthetic cannabinoids in herbal products by dry film attenuated total reflectance-infrared spectroscopy.
2017
A new procedure has been developed for the identification and quantitative determination of synthetic cannabinoids in illicit herbal preparations. The methodology is based on the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurement of sample extracts with 2-propanol drying 5µL of the extracts onto the ATR crystal. The qualitative identification was carried out on the 2-propanol extract after identification of the herbal matrix, followed by its subtraction and using a cut-off criterion of 75%. Quantitative determination was made by univariate calibration using the absorbance of the band located at 1520cm-1 of the spectrum. Four different cannabin…
Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis
2010
Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…
Hyperbolic subtraction method: Determination of the concentration of an analyte in the presence of an unknown interferent via spectral data.
2018
A theoretical model to determine the concentration of an analyte in the presence of unknown interferents using spectral-type data is described. The method involves absorbance measurements at three wavelengths and the calculation of specific absorbances yielding a hyperbolic relationship between absorbance ratios and analyte concentrations. The concentration of the analyte of known spectrum can be determined in the presence of an interferent or mixture of interferents of unknown concentration(s) and spectra can be determined combining data for different sets of wavelengths. Application to indigo and isatin solutions in DMSO related to the so-called Maya blue problem is reported as an illustr…
Determination of biochemical parameters in human serum by near-infrared spectroscopy
2014
NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipopr…
Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations
1998
The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…
Lidocaine inhibits potassium efflux and hemolysis in erythrocytes during oxidative stress in vitro.
2000
Lidocaine is a widely used local anesthetic agent. The aim of this work was to study the action of lidocaine on human red blood cells exposed to an oxidative stress in vitro. Blood was obtained from healthy volunteers. After separation from plasma, the erythrocytes were suspended in phosphate buffer. Oxidative stress was induced by incubation with a free radical generator, the 2,2' azobis (2-amidinopropane) hydrochloride (AAPH). Erythrocytes were incubated with or without lidocaine at two concentrations (36.93 and 73.85 microM) and with or without AAPH (20 mM). Electron paramagnetic resonance (EPR) spectroscopy was performed to identify the free radical species generated by AAPH using the s…
Polyphenol Characterization, Antioxidant and Skin Whitening Properties of Alnus cordata Stem Bark
2019
In this study, we investigated the phenolic composition of the crude extract (MeOH 80 %) of Alnus cordata (Loisel.) Duby stem bark (ACE) and its antioxidant and skin whitening properties. RP-LC-DAD analysis showed a high content of hydroxycinnamic acids (47.64 %), flavanones (26.74 %) and diarylheptanoids (17.69 %). Furthermore, ACE exhibited a dose-dependent antioxidant and free-radical scavenging activity, expressed as half-maximal inhibitory concentration (IC50 ): Oxygen radical absorbance capacity (ORAC, IC50 1.78 μg mL-1 )>Trolox equivalent antioxidant capacity (TEAC, IC50 3.47 μg mL-1 )>2,2-Diphenyl-1-picrylhydrazyl (DPPH, IC50 5.83 μg mL-1 )>β-carotene bleaching (IC50 11.58 μg mL-1 )…
Quality parameters, bioactive compounds and their correlation with antioxidant capacity of commercial fruit-based baby foods
2013
Comprehensive research is required to achieve the optimization of the antioxidant protection through baby foods, in particular, the commercially available fruit-based baby foods. This study investigated the physicochemical properties, ascorbic acid (AA), total carotenoids (TC), total phenolic content (TPC), trolox equivalent antioxidant capacity (TEAC) and oxygen radical absorbance capacity (ORAC) of 23 different commercially available fruit-based baby foods. The main contribution to the total antioxidant capacity (trolox equivalent antioxidant capacity and oxygen radical absorbance capacity) was provided by ascorbic acid, followed by phenolic compounds, in accordance with a mathematical e…
Accelerated Solvent Extraction and Pulsed Electric Fields for Valorization of Rainbow Trout (Oncorhynchus mykiss) and Sole (Dover sole) By-Products: …
2021
Fishery by-products are rich in biologically active substances and the use of green and efficient extraction methods to recover these high-added-value compounds is of particular importance. In this study, head, skin and viscera of rainbow trout and sole were used as the target matrices and accelerated solvent extraction (ASE) (45–55 °C, 15 min, pH 5.2–6.8, 103.4 bars) and pulsed electric fields (PEF) (1–3 kV/cm, 123–300 kJ/kg, 15–24 h) were applied as extraction technologies. The results showed that ASE and PEF significantly increased the protein extract efficiency of the fish by-products (p < 0.05) by up to 80%. SDS-PAGE results showed that ASE and PEF treatments changed the molecular size…