Evaluation and elimination of the blank bias error using the H-point standard additions method (HPSAM) in the simultaneous spectrophotometric determi…

1997

Abstract The aim of this report is to demonstrate the usefulness of the HPSAM in all instances where the determination of two analytes requires the use of an absorbent reagent, particularly when it does not present a constant analytical signal because of its consumption. This problem can be treated as a ternary mixture by the HPSAM method and then, the fundamentals of the method for resolving these kind of mixtures can be applied. The method can calculate the concentration of one species from spectral data at two wavelengths where the two other species present the same absorbance relationship. These wavelength pairs are easily found, and can be selected to give the most precise results. The…

AnalyteChromatographyChemistryAnalytical chemistryArsenazo IIIBiochemistrySpectral lineAnalytical ChemistryAbsorbanceStandard additionReagentCalibrationEnvironmental ChemistryTernary operationSpectroscopyAnalytica Chimica Acta
researchProduct

Identification and determination of synthetic cannabinoids in herbal products by dry film attenuated total reflectance-infrared spectroscopy.

2017

A new procedure has been developed for the identification and quantitative determination of synthetic cannabinoids in illicit herbal preparations. The methodology is based on the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) measurement of sample extracts with 2-propanol drying 5µL of the extracts onto the ATR crystal. The qualitative identification was carried out on the 2-propanol extract after identification of the herbal matrix, followed by its subtraction and using a cut-off criterion of 75%. Quantitative determination was made by univariate calibration using the absorbance of the band located at 1520cm-1 of the spectrum. Four different cannabin…

AnalyteChromatographyChemistryCannabinoidsPlant Extracts010401 analytical chemistryInfrared spectroscopy01 natural sciences0104 chemical sciencesAnalytical ChemistryMatrix (chemical analysis)Absorbance03 medical and health sciences0302 clinical medicineAttenuated total reflectionSynthetic cannabinoidsCalibrationSpectroscopy Fourier Transform InfraredmedicineCalibration030216 legal & forensic medicineFourier transform infrared spectroscopymedicine.drugTalanta
researchProduct

Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS
researchProduct

Hyperbolic subtraction method: Determination of the concentration of an analyte in the presence of an unknown interferent via spectral data.

2018

A theoretical model to determine the concentration of an analyte in the presence of unknown interferents using spectral-type data is described. The method involves absorbance measurements at three wavelengths and the calculation of specific absorbances yielding a hyperbolic relationship between absorbance ratios and analyte concentrations. The concentration of the analyte of known spectrum can be determined in the presence of an interferent or mixture of interferents of unknown concentration(s) and spectra can be determined combining data for different sets of wavelengths. Application to indigo and isatin solutions in DMSO related to the so-called Maya blue problem is reported as an illustr…

AnalyteSubtraction methodChemistryIsatinAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and OpticsSpectral lineIndigo0104 chemical sciencesAnalytical ChemistryAbsorbancechemistry.chemical_compoundWavelength0210 nano-technologySpectroscopyInstrumentationSpectroscopySpectrochimica acta. Part A, Molecular and biomolecular spectroscopy
researchProduct

Determination of biochemical parameters in human serum by near-infrared spectroscopy

2014

NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipopr…

AnalyteVery low-density lipoproteinChromatographyMean squared errorChemistryCholesterolGeneral Chemical EngineeringNear-infrared spectroscopyGeneral EngineeringAnalytical chemistryAnalytical ChemistryAbsorbancechemistry.chemical_compoundPartial least squares regressionCalibrationAnalytical Methods
researchProduct

Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations

1998

The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…

Analytegenetic structuresResolution (mass spectrometry)ChemistrySample (material)Analytical chemistryPhysics::OpticsBiochemistrySpectral lineAnalytical ChemistryChemometricsAbsorbanceWavelengthStandard additionElectrochemistryEnvironmental Chemistrysense organsSpectroscopyThe Analyst
researchProduct

Lidocaine inhibits potassium efflux and hemolysis in erythrocytes during oxidative stress in vitro.

2000

Lidocaine is a widely used local anesthetic agent. The aim of this work was to study the action of lidocaine on human red blood cells exposed to an oxidative stress in vitro. Blood was obtained from healthy volunteers. After separation from plasma, the erythrocytes were suspended in phosphate buffer. Oxidative stress was induced by incubation with a free radical generator, the 2,2' azobis (2-amidinopropane) hydrochloride (AAPH). Erythrocytes were incubated with or without lidocaine at two concentrations (36.93 and 73.85 microM) and with or without AAPH (20 mM). Electron paramagnetic resonance (EPR) spectroscopy was performed to identify the free radical species generated by AAPH using the s…

AntioxidantErythrocytesOxygen radical absorbance capacityLidocaineRadicalPotassiummedicine.medical_treatmentAmidineschemistry.chemical_elementIn Vitro Techniquesmedicine.disease_causeHemolysisAntioxidantsmedicineHumansAnesthetics LocalPharmacologyChromatographyElectron Spin Resonance SpectroscopyLidocaineBiological Transportmedicine.diseaseOxidantsHemolysisRed blood cellOxidative Stressmedicine.anatomical_structureBiochemistrychemistryPotassiumOxidative stressmedicine.drugGeneral pharmacology
researchProduct

Polyphenol Characterization, Antioxidant and Skin Whitening Properties of Alnus cordata Stem Bark

2019

In this study, we investigated the phenolic composition of the crude extract (MeOH 80 %) of Alnus cordata (Loisel.) Duby stem bark (ACE) and its antioxidant and skin whitening properties. RP-LC-DAD analysis showed a high content of hydroxycinnamic acids (47.64 %), flavanones (26.74 %) and diarylheptanoids (17.69 %). Furthermore, ACE exhibited a dose-dependent antioxidant and free-radical scavenging activity, expressed as half-maximal inhibitory concentration (IC50 ): Oxygen radical absorbance capacity (ORAC, IC50 1.78 μg mL-1 )>Trolox equivalent antioxidant capacity (TEAC, IC50 3.47 μg mL-1 )>2,2-Diphenyl-1-picrylhydrazyl (DPPH, IC50 5.83 μg mL-1 )>β-carotene bleaching (IC50 11.58 μg mL-1 )…

AntioxidantOxygen radical absorbance capacityDPPHmedicine.medical_treatmentTrolox equivalent antioxidant capacityBioengineeringAlnus cordata; antimelanogenic activity; Betulaceae; mushroom tyrosinase; polyphenols; RP-LC-DAD analysis; zebrafish; Alnus; Animals; Antioxidants; Biphenyl Compounds; Enzyme Inhibitors; Monophenol Monooxygenase; Picrates; Plant Bark; Plant Extracts; Polyphenols; Skin; ZebrafishAlnus01 natural sciencesBiochemistryAntioxidantschemistry.chemical_compoundPicratesmedicineAnimalsFood scienceEnzyme InhibitorsMolecular BiologyIC50ZebrafishSkinbiologyMonophenol MonooxygenasePlant Extracts010405 organic chemistryBiphenyl CompoundsPolyphenolsSkin whiteningGeneral ChemistryGeneral Medicinebiology.organism_classificationAlnus cordata0104 chemical sciences010404 medicinal & biomolecular chemistrychemistryPolyphenolPlant BarkMolecular Medicine
researchProduct

Quality parameters, bioactive compounds and their correlation with antioxidant capacity of commercial fruit-based baby foods

2013

Comprehensive research is required to achieve the optimization of the antioxidant protection through baby foods, in particular, the commercially available fruit-based baby foods. This study investigated the physicochemical properties, ascorbic acid (AA), total carotenoids (TC), total phenolic content (TPC), trolox equivalent antioxidant capacity (TEAC) and oxygen radical absorbance capacity (ORAC) of 23 different commercially available fruit-based baby foods. The main contribution to the total antioxidant capacity (trolox equivalent antioxidant capacity and oxygen radical absorbance capacity) was provided by ascorbic acid, followed by phenolic compounds, in accordance with a mathematical e…

AntioxidantOxygen radical absorbance capacityGeneral Chemical Engineeringmedicine.medical_treatmentTrolox equivalent antioxidant capacityAscorbic AcidAntioxidantsIndustrial and Manufacturing EngineeringMathematical equationsPhenolsmedicineHumansFood scienceChromansCarotenoidchemistry.chemical_classificationChemistryCommerceInfantAscorbic acidCarotenoidsAntioxidant capacityFruitInfant FoodSteam cookingFood ScienceFood Science and Technology International
researchProduct

Accelerated Solvent Extraction and Pulsed Electric Fields for Valorization of Rainbow Trout (Oncorhynchus mykiss) and Sole (Dover sole) By-Products: …

2021

Fishery by-products are rich in biologically active substances and the use of green and efficient extraction methods to recover these high-added-value compounds is of particular importance. In this study, head, skin and viscera of rainbow trout and sole were used as the target matrices and accelerated solvent extraction (ASE) (45–55 °C, 15 min, pH 5.2–6.8, 103.4 bars) and pulsed electric fields (PEF) (1–3 kV/cm, 123–300 kJ/kg, 15–24 h) were applied as extraction technologies. The results showed that ASE and PEF significantly increased the protein extract efficiency of the fish by-products (p < 0.05) by up to 80%. SDS-PAGE results showed that ASE and PEF treatments changed the molecular size…

AntioxidantantioxidantTime FactorsOxygen radical absorbance capacityFood Handlingmedicine.medical_treatmentPharmaceutical ScienceChemical Fractionation01 natural sciencesAntioxidantschemistry.chemical_compoundDover soleElectricityDrug DiscoveryFood sciencelcsh:QH301-705.5Pharmacology Toxicology and Pharmaceutics (miscellaneous)Polyacrylamide gel electrophoresisABTSTemperature04 agricultural and veterinary sciencesHydrogen-Ion Concentration040401 food science6. Clean waterOncorhynchus mykissFlatfishesMolar mass distributionElectrophoresis Polyacrylamide GelAntioxidantFish Proteinsanimal structuresFish by-productsArticleASE0404 agricultural biotechnologyfoodmedicinePressureAnimals14. Life underwaterWaste Productsfish by-productsOxygen Radical Absorbance CapacityProtein010401 analytical chemistryExtraction (chemistry)PEFfood.food0104 chemical sciencesMolecular Weightlcsh:Biology (General)chemistrySeafoodSolventsRainbow troutproteinSDS-PAGE
researchProduct