Search results for "Algorithm"
showing 10 items of 4887 documents
Is the V˙o 2 slow component dependent on progressive recruitment of fast-twitch fibers in trained runners?
2001
The goal of this study was to use spectral analysis of EMG data to test the hypothesis that the O2 uptake (V˙o 2) slow component is due to a recruitment of fast fibers. Thirteen runners carried out a treadmill test with a constant speed, corresponding to 95% of the velocity associated with maximal V˙o 2. TheV˙o 2 response was fit with the classical model including three exponential functions. Electrical activity of six lower limb muscles (vastus lateralis, soleus, and gastrocnemius of both sides) was measured using electromyogram surface electrodes. Mean power frequency (MPF) was used to study the kinetics of the electromyogram discharge frequency. Three main results were observed: 1) a co…
Rationale and design of dal-VESSEL: a study to assess the safety and efficacy of dalcetrapib on endothelial function using brachial artery flow-media…
2011
Dalcetrapib increases high-density lipoprotein cholesterol (HDL-C) levels through effects on cholesteryl ester transfer protein (CETP). As part of the dalcetrapib dal-HEART clinical trial programme, the efficacy and safety of dalcetrapib is assessed in coronary heart disease (CHD) patients in the dal-VESSEL study (ClinicalTrials.gov identifier: NCT00655538), the design and methods of which are presented here. RESEARCH DESIGN AND STUDY METHOD: Men and women with CHD or CHD risk equivalent, with HDL-C levels50 mg/dL were recruited for a 36-week, double-blinded, placebo-controlled trial. After a pre-randomisation phase of up to 8 weeks, patients received dalcetrapib 600 mg/day or placebo in …
Deferment of Objective Assessment of Deep Vein Thrombosis and Pulmonary Embolism Without Increased Risk of Thrombosis
2004
Background: Treatment of patients with suspected deep vein thrombosis (DVT) or pulmonary embolism (PE) is problematic if diagnostic imaging is not immediately available. Pretest clinical probability (PCP) and D-dimer assessment can be used to identify patients for whom empirical protective anticoagulation is indicated. To evaluate whether PCP and D-dimer assessment, together with the use of low-molecular-weight heparins (LMWHs), allow objective appraisal of DVT and PE to be deferred for up to 72 hours, patients with suspected DVT and PE were prospectively examined. Methods: Patients identified with a high PCP or a moderate PCP with positive D-dimer test results received a protective full-do…
Benefits of nonlinear analysis indices of walking stride interval in the evaluation of neurodegenerative diseases.
2021
Indices characterising the long-range temporal structure of walking stride interval (SI) variability such as Hurst exponent (H) and fractal dimension (D) may be used in addition to indices measuring the amount of variability like the coefficient of variation (CV). We assess the added value of the former indices in a clinical neurological context. Our aim is to demonstrate that they provide a clinical significance in aging and in frequent neurodegenerative diseases such as Parkinson's disease, Huntington, and amyotrophic lateral sclerosis. Indices assessing the temporal structure of variability are mainly dependent on SI time series length and algorithms used, making quantitative comparisons…
Standing up from a chair as a dynamic equilibrium task: a comparison between young and elderly subjects.
2000
The purpose of this study was to analyze and compare the features of center of mass (CoM) control along anterior/posterior axis in young and elderly subjects during sit-to-stand (STS). From a sitting position, seven healthy young subjects and seven healthy elderly subjects were asked to stand up from a chair under different experimental conditions (visual conditions: normal and blindfolded; speed: normal and as fast as possible). Analysis of results was based upon the concept of a “dynamic equilibrium area” (DEA), which in turn identified the dynamic limits of balance. The results showed that both the maximal CoM velocity in the horizontal axis and the CoM velocity at the instant of seat-of…
Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.
2011
International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…
The intravascular ultrasound morphometry of iliac veins in subjects without severe chronic venous insufficiency and its implications for treatment in…
2019
Objectives The purpose of this study is to report the intravascular ultrasound morphometry of iliac veins and its relation to demographic and anthropometric factors in subjects without chronic venous insufficiency. Methods Thirty-three patients, without chronic venous insufficiency – qualified to great saphenous vein stripping due to unilateral, primary varicose veins – participated in the study. During the surgery, left and right external iliac veins, common iliac veins and inferior vena cava were interrogated with intravascular ultrasound. The morphometric analysis included measurement of a cross-sectional area at normal, non-stenosed vein segments (ref-CSA) and at the point of the most p…
Hepatocellular carcinoma (HCC) vs. non-HCC: accuracy and reliability of Liver Imaging Reporting and Data System v2018
2019
PURPOSE: The Liver Imaging Reporting and Data System (LI-RADS) was created to standardize the diagnostic criteria for hepatocellular carcinoma (HCC), and has undergone multiple revisions including a recent update in 2018 (v2018). The primary aim of this study was to determine the diagnostic performance and interrater reliability (IRR) of LI-RADS v2018 for distinguishing HCC from non-HCC primary hepatic malignancy in patients ‘at-risk’ for HCC. A secondary aim was to assess the impact of changes introduced in the v2018 diagnostic algorithm. METHODS: This retrospective study combined a 10-year experience of pathologically-proven primary liver malignancies from two large liver transplant cente…
Baseline [18F]-FDOPA kinetics are predictive of haloperidol-induced changes in dopamine turnover and cognitive performance: A positron emission tomog…
2007
The telencephalic dopamine innervations contribute to the modulation of cognitive processing. However, the relationship between cognitive effects of D(2/3)-receptor antagonism and dopamine transmission is not described in healthy subjects. We therefore tested effects of acute haloperidol (5 mg/d over 3 days) on continuous performance task (CPT) performance and 6-[(18)F]-fluoro-l-DOPA (FDOPA) PET parameters. Nine physically and mentally healthy male men performed two FDOPA-PET scans including arterial plasma withdrawal. Over 3 days before the second scan, all subjects were treated with 5 mg/d haloperidol orally. Using our novel steady-state analysis, we calculated the intrinsic rate of the c…
Functional MRI of galvanic vestibular stimulation with alternating currents at different frequencies.
2004
Abstract Functional MRI was performed in 28 healthy volunteers to study the effects of galvanic vestibular stimulation with alternating currents (AC-GVS) of different frequencies on brain activation patterns. The aims of this study were (1) to identify specific areas within the vestibular cortical network that are involved in the processing of frequency-specific aspects by correlation analyses, (2) to determine the optimal frequency for stimulation of the vestibular system with respect to perception, and (3) to analyze whether different frequencies of AC-GVS are mediated in different cortical areas or different sites within the vestibular cortex. AC-GVS was performed using sinusoidal stimul…