Search results for "Amplifier"
showing 10 items of 239 documents
A 20-channel receive-only mouse array coil for a 3 T clinical MRI system
2011
A 20-channel phased-array coil for MRI of mice has been designed, constructed, and validated with bench measurements and high-resolution accelerated imaging. The technical challenges of designing a small, high density array have been overcome using individual small-diameter coil elements arranged on a cylinder in a hexagonal overlapping design with adjacent low impedance preamplifiers to further decouple the array elements. Signal-to-noise ratio (SNR) and noise amplification in accelerated imaging were simulated and quantitatively evaluated in phantoms and in vivo mouse images. Comparison between the 20-channel mouse array and a length-matched quadrature driven small animal birdcage coil sh…
Spatial Beam Evolution in Nonlinear Multimode Fibers
2021
We discuss some recent results illustrating the role of input wave-front shaping, propagation dynamics and output beam diagnostics in order to observe spatial beam cleaning in nonlinear multimode fibers and amplifiers.
Investigation on pixellated CZT detectors coupled with a low power readout ASIC
2008
In this work, we investigated on the spectroscopic performances of two pixellated CZT detectors coupled with a custom low noise and low power readout ASIC. The detectors (10 x 10 x 1 mm3 and 10 x 10 x 2 mm3 single crystals) consist of an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 μm BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) characterized by a dynamic range from 10 keV to 100 keV, low power consumption (0.5 mW/channel) and low noise (150–500 electrons r.m.s.). The spectroscopic results point out the good energy resolution of both detectors at room temperature (5.8 % FWHM at 59.5 keV for the 1 mm thick detec…
A novel technique for the CMRR improvement in a portable ECG system
2017
This paper presents a new technique to improve the quality of the ECG signals, increasing the Common Mode Rejection Ratio (CMRR). We developed a portable wireless Bluetooth ECG system able to acquire 12 leads, communicating with Smartphones and PCs. Many experiments have been made for measuring CMRR decay due to the difference on skin-electrodes impedances, the asymmetries of the amplifiers input stages and external components. Using some digital potentiometers, the system is able to compensate for these, increasing the CMRR of about 18 dB.
Optimal Design of an X-Band, Fully-Coaxial, Easily-Tunable Broadband Power Equalizer for a Microwave Power Module
2020
A microwave power module (MPM), which is a hybrid combination of a solid-state power amplifier (SSPA) as a driver and a traveling-wave tube amplifier (TWT) as the final high power stage, is a high-power device largely used for radar applications. A gain equalizer is often required to flatten the TWT output power gain owing to its big gain fluctuations over the operating frequency range. In this paper, the design of an X-band, fully-coaxial, easily-tunable broadband power equalizer for an MPM is presented. The structure is composed of a coaxial waveguide as the main transmission line and a coaxial cavity loaded with absorbing material as a resonant unit. Sensitivity analyses of the attenuati…
Practical system for the generation of pulsed quantum frequency combs
2017
The on-chip generation of large and complex optical quantum states will enable low-cost and accessible advances for quantum technologies, such as secure communications and quantum computation. Integrated frequency combs are on-chip light sources with a broad spectrum of evenly-spaced frequency modes, commonly generated by four-wave mixing in optically-excited nonlinear micro-cavities, whose recent use for quantum state generation has provided a solution for scalable and multi-mode quantum light sources. Pulsed quantum frequency combs are of particular interest, since they allow the generation of single-frequency-mode photons, required for scaling state complexity towards, e.g., multi-photon…
Flashlamp-pumped Nd:KGW laser in MOPA configuration: comparative study of several rods
1999
The laser performance of the Nd:KGW crystal has been studied in a master oscillator and power amplifier configuration (MOPA). Several crystals from two different producers were investigated for the oscillator and the amplifier. A maximum single-pass gain of 25 was observed in free-running and Q-switched mode. We obtained a maximum output amplified energy of 400 mJ at 30 Hz (with a pulse duration of 10 to 30 ns) with a divergence less than 3 mrad. We also studied the limitations of this configuration due to the very high gain of the Nd:KGW crystal.
1.3 µm GaInNAs optically-pumped vertical cavity semiconductor optical amplifier
2003
A GaInNAs/GaAs vertical cavity semiconductor optical amplifier (VCSOA) is reported. This is believed to be the first monolithic VCSOA operating at 1.3 mum. Under continuous-wave optical pumping in a singlemode fibre coupled format, gain figures of up to 17.7 dB were achieved. Amplification with 12 GHz bandwidth,was obtained at 12.8 dB peak gain.
Radiation responses of Yb/Er-doped phosphosilicate optical fibers: hardening mechanisms related to Ce-codoping
2012
International audience; In this paper, we investigated the origins of the Ce positive influence on the radiation response of Yb/Er-doped phosphosilicate optical fibers. To this purpose, we carried out during γ-irradiations an online characterization on active optical fiber prototypes, made with different Ce concentrations and integrated in optical amplifiers. The hardening effect of Ce-codoping is highlighted, as well as some aspects related to the radiation response of the phosphosilicate host glass of the active optical fibers.
Digital CZT detector system for high flux energy-resolved X-ray imaging
2017
Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…