Search results for "Analyte"

showing 10 items of 303 documents

Enhancement of retention predictions in reversed-phase liquid chromatography using reference compounds

2004

Abstract The use of reference compounds to correct errors associated with the preparation of mobile phase is studied, in order to enhance modelling of retention for optimisation purposes in reversed-phase liquid chromatography. The method fits individual retention models for a set of reference compounds, which are present in all injections. In second step, mobile-phase composition is corrected for each chromatogram, according to the fitted models of the reference compounds. The enhanced precision provided by the large number of replicates for the reference compounds is partially propagated to the retention models of the analytes. The approach is assayed in the separation of amino acids, aft…

AnalyteChromatographyIsoindolesChemistryAnalytical chemistryReversed-phase chromatographyBiochemistryAnalytical Chemistrychemistry.chemical_compoundReagentPhase (matter)Environmental ChemistryDerivatizationAcetonitrileSpectroscopyPhthalaldehydeAnalytica Chimica Acta
researchProduct

Capillary electrophoretic and extraction conditions for the analysis of Catha edulis FORKS active principles

2013

A capillary electrophoretic method, which allowed the detection and separation of the active principles of Catha edulis, i.e. cathinone, cathine and phenylpropanolamine, was developed. A suitable internal standard (nicotinamide), which permitted the quantification of the analytes reducing the variability of the migration times due to EOF changes, was identified. The analytical method was validated, assessing linearity, sensitivity and repeatability, showing optimal features for the analysis of the vegetable material. Moreover extraction conditions were investigated to achieve the exhaustion of the plant material in the fastest and most efficient way to meet the requirements of the Court.

AnalyteChromatographyMolecular StructureCathinonePlant ExtractsChemistryCapillary actionPhenylpropanolamineExtraction (chemistry)Vegetable materialElectrophoresis CapillaryReproducibility of ResultsCathaRepeatabilityPathology and Forensic MedicineElectrophoresisAlkaloidsSettore MED/43 - Medicina LegaleCathinone Cathine PhenylpropanolaminemedicineLawCathinemedicine.drug
researchProduct

A new 8-oxo-7,8-2 ' deoxyguanosine nanoporous anodic alumina aptasensor for colorectal cancer diagnosis in blood and urine

2021

Many important human diseases, and especially cancer, have been related to the overproduction of 8-oxo-7,8-dihydro-2 '-deoxyguanosine (8-oxo-dG). This molecule is a product of oxidative stress processes over nucleophilic bases in DNA. In this work, an aptasensor for the rapid, selective and accurate detection of this oncomarker is presented. The aptasensor consists of a nanoporous anodic alumina material loaded with a dye and is functionalized with an aptamer-based "molecular gate". In the presence of target 8-oxo-dG, the capping aptamer displaces from the surface due to the high affinity of the analyte with the capping aptamer, thus inducing delivery of the preloaded fluorescent dye. In co…

AnalyteChromatographyNanoporousColorectal cancerChemistryAptamerDeoxyguanosineCancerUrinemedicine.diseaseFluorescenceNanoporeschemistry.chemical_compound8-Hydroxy-2'-DeoxyguanosineAluminum OxidemedicineHumansDeoxyguanosineGeneral Materials ScienceColorectal Neoplasms
researchProduct

Determination of trimethoprim by the linear absorbances method

1995

The determination of trimethoprim in the presence of dyphylline, proxyphylline, theophylline and caffeine by the linear absorbances method is described. Collinear couples of wavelengths, for the interfering dyphylline-proxyphylline-theophylline-caffeine system (in H2SO4, 0.05 mol/L), are provided in order to allow the determination of the analyte in the presence of these interfering substances.

AnalyteChromatographyProxyphyllineAnalytical chemistryBiochemistryTrimethoprimAnalytical ChemistryDyphyllinechemistry.chemical_compoundchemistrymedicineTrace analysisTheophyllineAnalysis methodmedicine.drugFresenius' Journal of Analytical Chemistry
researchProduct

Theoretical prediction of the native fluorescence of pharmaceuticals

2009

At present, to search fluorescent compounds or to increase the native fluorescence is an active research line specially and not only with analytical purposes. On some analytical areas and from the early times of applications of fluorescence (mid-fifties) the fluorimeter was defined as the suitable detector for determination of pharmaceuticals and subsequently, this detection mode has been widely applied. Therefore, it is mandatory to develop new strategies to discover or to enhance in a simple way the native fluorescence of organic compounds to increase the number of analytes to be determined by direct fluorescence. In the present paper are studied further applications of a new tool suitabl…

AnalyteChromatographyScreening testChemistryFluorescence spectrometryDiscriminant AnalysisModels TheoreticalFluorescenceFluorescenceAnalytical ChemistryPharmaceutical PreparationsFluorometerFluorometryPesticidesBiological systemTalanta
researchProduct

Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

2013

Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane-isopropanol and ethyl acetate-ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample e…

AnalyteChromatographySpectrophotometry InfraredCholesterolCholesterol HDLExtraction (chemistry)Analytical chemistryInfrared spectroscopyCholesterol LDLBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundchemistryLow-density lipoproteinAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionSolventsElectrochemistryHumansEnvironmental ChemistryTriglyceridesSpectroscopyThe Analyst
researchProduct

Optimisation of gradient elution with serially-coupled columns. Part I: single linear gradients.

2014

A mixture of compounds often cannot be resolved with a single chromatographic column, but the analysis can be successful using columns of different nature, serially combined through zero-dead volume junctions. In previous work (JCA 1281 (2013) 94), we developed an isocratic approach that optimised simultaneously the mobile phase composition, stationary phase nature and column length. In this work, we take the challenge of implementing optimal linear gradients for serial columns to decrease the analysis time for compounds covering a wide polarity range. For this purpose, five ACE columns of different selectivity (three C18 columns of different characteristics, a cyano and a phenyl column) we…

AnalyteChromatographySulfonamidesChromatographyAcetonitrilesResolution (mass spectrometry)LogarithmChemistryOrganic solventOrganic ChemistryAnalytical chemistryReproducibility of ResultsWaterGeneral MedicineModels TheoreticalBiochemistryAnalytical ChemistryColumn (typography)Gradient elutionRetention timeCyano columnAlgorithmsJournal of chromatography. A
researchProduct

Capillary electrokinetic fractionation mass spectrometry (CEkF/MS): Technology setup and application to metabolite fractionation from complex samples…

2014

Capillary electrokinetic fractionation (CEkF) is investigated as a new, simple, and robust approach for semipreparative and analytical sample analysis based on pKa -dependant pH-driven electrophoretic mobility. CEkF was optimized with contactless conductivity detection and conducted with 10 kV reverse voltage for 10 min, then coupled on/at-line to ESI/MS. We propose a semi-empirical model with 14 representative compounds based on the correlation between sample/medium pH regulating the partial charge, the electrokinetic loading of the capillary and intensity (I) of analytes. According to the model, an empirical function (I = f (pH)) could be derived to calculate the acid dissociation constan…

AnalyteChromatographySulfur CompoundsChemistryCapillary actionClinical BiochemistryAnalytical chemistryElectrophoresis CapillaryWineFractionationHydrogen-Ion ConcentrationMass spectrometryBiochemistryMass SpectrometryAcid dissociation constantAnalytical ChemistryElectrophoresisElectrokinetic phenomenaModels ChemicalSpectroscopy Fourier Transform InfraredIon cyclotron resonanceELECTROPHORESIS
researchProduct

Preconcentration of aluminium by micellar-enhanced ultrafiltration

1993

Abstract Traces of aluminium were preconcentrated in water samples by forming a complex with lumogallion, and successfully accumulated in the micellar phase obtained from cationic or non-ionic surfactants and filtered through 10 000 molecular weight cut-off ultrafiltration membranes. Studies indicated that, at pH 5.9, with 1 X 10 −3 M lumogallion and 2 X 10 −2 M cetyltrimethylamonium bromide, quantitative retention of aluminium present at μg ml −1 concentration levels was achieved. A micellar-enhanced fluorimetric procedure was employed to analyse the permeate solutions, whereas nitrous oxide-acetylene flame atomic emission spectrometry was used to determine aluminium in the retentate. The …

AnalyteChromatographyUltrafiltrationFluorescence spectrometrychemistry.chemical_elementPermeationBiochemistryAnalytical Chemistrychemistry.chemical_compoundMembranechemistryBromideAluminiumEnvironmental ChemistryAnalytical proceduresSpectroscopyAnalytica Chimica Acta
researchProduct

H-Point Curve Isolation Method for Coupled Liquid Chromatography and UV−Visible Spectrophotometry

2000

The H-point curve isolation method (HPCIM) for the detection of unknown interferences in chromatography is proposed. The method allows one to estimate the UV-vis spectra of interfering species in a sample as well as to test the purity of the chromatographic peaks. Besides the detection of the unknown interferences in a sample, this method allows one to calculate the concentration of an analyte in the presence of unknown compounds. To illustrate the reliability of the proposed method, samples of diuretics and amphetamines have been analyzed by normal- and reversed-phase high-performance chromatography.

AnalyteChromatographymedicine.diagnostic_testChemistryAmphetaminesAnalytical chemistryAnalytical ChemistryChromatography detectorSpectrophotometrymedicineSpectrophotometry UltravioletDiureticsChromatography columnChromatography LiquidAnalytical Chemistry
researchProduct