Search results for "Aortic Aneurysm"
showing 10 items of 255 documents
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
Role of cardiac computed tomography in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic…
2016
OBJECTIVE The aim of our study was to evaluate the diagnostic performance of cardiac computed tomography (CCT) in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic echocardiography. METHODS We conducted a retrospective analysis of patients with an aneurysm 45 mm or greater at transthoracic echocardiography who underwent CCT from 2012 to 2014 in our hospital. We calculated the sensitivity, specificity, and positive and negative predictive values of CCT for the assessment of coronary artery stenosis (<50% or ≥50% stenosis) in patients who underwent conventional coronary angiography. RESULTS We included 104 patients (73 men, aged 64 …
Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…
2016
Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…
A Multicenter Experience With a New Fenestrated-Branched Device for Endovascular Repair of Thoracoabdominal Aortic Aneurysms.
2018
To investigate the outcomes of patients who were treated for thoracoabdominal aortic aneurysms (TAAAs) using custom-made fenestrated-branched stent-grafts.A consecutive series of 108 patients (mean age 73.5 years; 73 men) with TAAA were treated with E-xtra Design Engineering customized fenestrated-branched stent-grafts between November 2011 and January 2017. Data on baseline characteristics, procedures, and clinical follow-up were collected from 6 regional European surgical centers for retrospective analysis of endoleaks, reinterventions, and target vessel patency. The median aneurysm diameter was 6.75 cm (range 5.5-13). The distribution of the TAAA according to the modified Crawford classi…
Repair of TEVAR-Associated Type A Dissection in the Elderly Is Possible With Reasonable Morbidity and Mortality.
2018
Background: Type A aortic dissection (AAD) is a devastating complication of thoracic endovascular repair (TEVAR). In elderly patients, surgery for AAD carries considerable morbidity and mortality. Repair of AAD after previous TEVAR is an even greater challenge as it usually requires the arch to be addressed and a preexisting stent graft to be included into the aortic repair. Methods: A case series of 5 elderly patients who presented with acute AAD after previous TEVAR was reviewed. In 4 cases, there was retrograde AAD with involvement of the arch and stent graft. In 1 patient, intraoperative inspection showed no involvement of the arch. Three underwent ascending and subtotal arch replacemen…
Aortic intramural hemorrhage visualized by transesophageal echocardiography: Findings and prognostic implication
1994
Abstract Objectives. This study describes the transesophageal echocardiographic and follow-up findings in patients with aortic intramural hemorrhage. Background. Localized aortic intramural hemorrhage resulting in layered thickening of the aortic wall seems to represent a variant of acute aortic dissection without communication or a typical moving intimal flap. In autopsy studies this variant, attributed to a rupture of the van vasorum, has been described in 5% to 10% of patients with dissection. Methods. In a prospective transesophageal echocardiographic study in patients with aortic dissection performed between 1986 and 1991, the diagnosis of intramural hemorrhage was established in 15 of…
Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.
2013
To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …
Mid-Term Results of Endovascular Aneurysm Sealing in the Treatment of Abdominal Aortic Aneurysm With Unfavorable Morphology.
2020
Purpose: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR). Methods: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of m…
Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair.
2021
Background Long-term outcomes of accessory renal artery (ARA) coverage after endovascular aneurysm repair (EVAR) are unknown. We analyzed the impact of ARA coverage on renal function long-term. Methods This retrospective, monocentric study included patients treated by EVAR between 2008 and 2016. Patients with at least one ARA covered with EVAR (ARA group) were compared with patients with no covered ARA (control group). Renal function was determined by estimating the glomerular filtration rate (eGFR) and graded according to chronic kidney disease (CKD) classification stages. Results A total of 184 patients were included (ARA group, n = 25; control group, n = 159). Renal risk factors were sim…