Search results for "Artery"
showing 10 items of 2026 documents
Endothelium-dependent component in the contractile responses of human omental arteries to adrenergic stimulation
1993
Abstract The present study was designed to investigate the influence of endothelium-derived nitric oxide on the contractile responses of isolated human omental arteries to electrical field stimulation and noradrenaline. We measured isometric tension in artery rings obtained from portions of human omentum during the course of abdominal operations (32 patients). Electrical field stimulation induced frequency-dependent contractions which were abolished by tetrodotoxin (10−6 M) and prazosin (10−6 M), thus indicating that this effect was due to noradrenaline released from adrenergic nerves acting on α1-adrenoceptors. The increases in tension induced by electrical field stimulation were of greate…
A case of atypical sporadic hemiplegic migraine associated with PFO and hypoplasia of vertebro-basilar system.
2009
We describe the case of a patient with atypical hemiplegic migraine and associated basilar symptoms, where a large patent foramen ovale (PFO) and hypoplasia of basilar artery were found. The longer period of 4-year remission of the headache attacks was coincident with the percutaneous PFO closure. When 5 years after, hemiplegic migraine attacks relapsed, with more relevant basilar symptoms, a mild re-opening of PFO was found. The atypical presentation of attacks with basilar symptoms and prolonged hemiplegia does not strictly fit the diagnostic criteria of ICHD-II.
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Measurement of the local aortic stiffness by a non-invasive bioelectrical impedance technique.
2011
International audience; Aortic stiffness measurement is well recognized as an independent predictor of cardiovascular mortality and morbidity. Recently, a simple method has been proposed for the evaluation of the local aortic stiffness (AoStiff) using a non-invasive bioelectrical impedance (BI) technique. This approach relies on a novel interpretation of the arterial stiffness where AoStiff is computed from the measurement of two new BI variables: (1) the local aortic flow resistance (AoRes) exerted by the drag forces onto the flow; (2) the local aortic wall distensibility (AoDist). Herein, we propose to detail and compare these three indices with the reference pulse wave velocity (PWV) mea…
Acute effects of coffee on QT interval in healthy subjects
2011
Abstract The coronary endothelial function is recognized to have an important role in the physiology of the diastolic ventricular relaxation, a phase of the heart cycle that influences the electrocardiographic QT interval. Endothelial function is investigated in vivo by flow mediated dilation (FMD) in the brachial artery and has proven to be a strong predictor of both coronary endothelial function and cardiovascular events. It has been reported that coffee acutely induces FMD changes. In particular, the brachial artery FMD seems to decrease after caffeinated coffee (CC) and to increase after decaffeinated coffee (DC) ingestion. Since the cardiovascular effects of coffee are still a debated …
Dose-dependent effects of decaffeinated coffee on endothelial function in healthy subjects
2009
ackground/Objectives: Coffee is known to contain antioxidant substances whose effects may be blunted because of caffeine that may unfavorably affect the cardiovascular system. This study was designed to investigate the acute dose-dependent effects of decaffeinated coffee (DC) on endothelial function measured by the brachial artery flow-mediated dilation (FMD). Subjects/Methods: A total of 15 (8 men and 7 women) healthy nonobese subjects underwent a single-blind, crossover study. Subjects ingested one and two cups of decaffeinated Italian espresso coffee in random order at 5- to 7-day intervals. Results: In the hour following the ingestion of two cups of DC, FMD increased (mean±s.e.m.): 0 mi…
Erectile dysfunction is associated with low total serum testosterone levels and impaired flow-mediated vasodilation in intermediate risk men accordin…
2015
Background: The role erectile dysfunction (ED) coupled with low testosterone levels as early markers of atherosclerosis is not well understood. Objectives: To analyze the relationship between serum testosterone levels with both ED and brachial artery flow-mediated vasodilation (FMD), in a primary prevention sample of men. Methods: We enrolled 802 asymptomatic, intermediate CV risk patients, according to the Framingham Risk Score, aged 40e80 years, who underwent the ultrasound examination of FMD, the evaluation of ED and the assessment of total serum testosterone levels. Results: Testosterone levels correlated both with FMD (r ¼ 0.85; p < 0.0001) and IIEF-5 score (rs ¼ 0.65; p < 0.0001…
Noninvasive peripheral vascular function and atrial fibrillation in the general population.
2019
Background Arterial stiffness is a strong predictor of atrial fibrillation in the community. Whether noninvasively measured conduit artery function and peripheral vascular reactivity are related to atrial fibrillation remains unknown. Methods and results In 15 010 individuals of the population-based Gutenberg Health Study, mean age 55 ± 11 years, 50.5% men, we determined noninvasive vascular function by flow-mediated dilation (FMD) and peripheral arterial tonometry (PAT) in relation to manifest atrial fibrillation (N = 466). Patients with atrial fibrillation exhibited a higher mean brachial artery diameter [4.81 mm (4.17, 5.33) in atrial fibrillation vs. 4.31 mm (3.67, 4.93)] and baseline p…
Five-year prospective study on cardiovascular events, in patients with erectile dysfunction and hypotestosterone.
2017
Objective: Testosterone levels play a role in cardiac and vascular pathology. In the present study we investigated the prognostic significance of this hormone for cardiovascular outcome, in a 5-year follow-up. Materials and methods: Our cohort included 802 adult subjects, from 40 to 80 years. Patients were excluded if they had a past history of peripheral or coronary artery disease, and revascularization. A blood sample was drawn to valuate testosterone level, and we considered normal testosterone levels 300 ng/dl. FMD (flow mediated dilatation) of the brachial artery was assessed by measuring the increase of the brachial artery diameter during reactive hyperemia after transient forearm isc…
Comparison of selective internal iliac pharmaco-angiography, penile brachial index and duplex sonography with pulsed Doppler analysis for the evaluat…
1990
AbstractBetween July 1987 and February 1988 selective internal iliac angiography was performed before and after intracavernous injection of papaverine plus phentolamine in 43 patients with erectile dysfunction. In 63% of the patients stenosis or occlusion of the pudendal artery was found. The penile brachial index was calculated and duplex sonography with pulsed Doppler analysis was performed in 23 patients. Angiography and penile brachial index correlated in only 39% of the patients, whereas selective internal iliac angiography and duplex sonography correlated in 91% (21 of 23). In 2 patients duplex sonography with pulsed Doppler analysis rendered better information about penile arterial p…