Search results for "Athen"
showing 10 items of 59 documents
Temperature effects on the performances of the ATHENA X-IFU thermal filters
2016
The X-Ray Integral Field Unit (X-IFU) detector on-board ATHENA is an array of TES micro-calorimeters that will operate at ~50 mK. In the current investigated design, five thermal filters (TF) will be mounted on the cryostat shields to attenuate IR radiative load and avoid energy resolution degradation due to photon shot noise. Each filter consists of a thin polyimide film (~50 nm thick) coated with aluminum (~30 nm thick). Since the TF operate at different temperatures in the range 0.05-300 K, it is relevant to study how temperature affects their mechanical/optical performances (e.g. near edge absorption fine structures of the atomic elements in the filter material). Such results are crucia…
Thermal modelling of the ATHENA X-IFU filters
2018
Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. The X-IFU instrument of the ATHENA mission requires a set of thermal filters to reduce the photon shot noise onto its cryogenic detector and to protect it from molecular contamination. A set of five filters, operating at different nominal temperatures corresponding to the cryostat shield temperatures, is currently baselined. The knowledge of the actual filter temperature profi…
Radio frequency shielding of thin aluminized plastic filters investigated for the ATHENA X-IFU detector
2018
Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. The X-ray Integral Field Unit (X-IFU) is one of the two detectors of the ATHENA astrophysics space mission approved by ESA in the Cosmic Vision 2015-2025 Science Programme. The X-IFU consists of a large array of transition edge sensors (TES) micro-calorimeters covering a field of view of 5' diameter, sensitive in the energy range 0.2-12 keV, and providing a spectral resolution…
The focal plane assembly for the Athena X-ray Integral Field Unit instrument
2016
This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a ~ 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off…
Thermal Filters for the ATHENA X-IFU: Ongoing Activities Toward the Conceptual Design
2016
ATHENA is the L2 mission selected by ESA to pursue the science theme “Hot and Energetic Universe.” One of the two focal plane instruments is the X-ray Integral Field Unit, an array of TES microcalorimeters operated at T $$<$$ 100 mK. To allow the X-ray photons focused by the telescope to reach the detector, windows have to be opened on the cryostat thermal shields. X-ray transparent filters need to be mounted on these open windows to attenuate the IR radiation from warm surfaces, to attenuate RF electromagnetic interferences on TES sensors and SQUID electronics, and to protect the detector from contamination. This paper reviews the ongoing activities driving the design of the X-IFU thermal …
Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution
2018
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining…
The performance of the ATHENA X-ray Integral Field Unit
2018
The X-ray Integral Field Unit (X-IFU) is a next generation microcalorimeter planned for launch onboard the Athena observatory. Operating a matrix of 3840 superconducting Transition Edge Sensors at 90 mK, it will provide unprecedented spectro-imaging capabilities (2.5 eV resolution, for a field of view of 5') in the soft X-ray band (0.2 up to 12 keV), enabling breakthrough science. The definition of the instrument evolved along the phase A study and we present here an overview of its predicted performances and their modeling, illustrating how the design of the X-IFU meets its top-level scientific requirements. This article notably covers the energy resolution, count-rate capability, quantum …
Brief an Garlieb H. Merkel
1798
Ms. 930a, Nr. 10, Bl. 26r-28v Schmidt-Phiseldeck, Konrad von. Brief an Garlieb H. Merkel, Kopenhagen, am 6. März 1798 Autora rokraksts / Autograph, vācu un latīņu val. / Deutsch und Latein [6] lpp. / S. Attēlu numuri / Bildnummern: 930a-010-1 – 930a-010-6 Der Verfasser äußert zum Beginn seines Briefes erneut sein Bedauern über die räumliche Trennung und wünscht sich, nach Italien zu reisen. Weimar, wo Merkel zum gegebenen Zeitpunkt wahrscheinlich weilte, glorifiziert Schmidt-Phiseldeck mit der Bezeichnung als „Weimar-Athen“. Gleichzeitig drückt der Verfasser seine Enttäuschung über die Politik Frankreichs bezüglich der Schweiz aus, erkennt aber in der Neutralität seiner neuen Heimat Dänemar…
Perdere il senno e darsi la morte. Due casi singolari di punizione divina nelle Storie di Erodoto (V 85; VI, 75)
2016
Scopo di questo paper è l’analisi dei temi della follia e del suicidio nella struttura narrativa di Erodoto. I due episodi esaminati sono: a) il racconto della pazzia che colpì gli Ateniesi, che avevano tentato invano di sottrarre agli Egineti le sacre statue di Damia e Auxesia; b) la storia dei disaccordi tra i due re spartani Demarato e Cleomene e il loro tragico esito. Questi due episodi sono profondamente interconnessi: attraverso i rimandi interni, suggeriti dalle scelte linguistiche dello storico, noi vogliamo infine riflettere sul modello causale erodoteo. The aim of this paper is the analysis of the themes of madness and suicide in the narrative structure of Herodotus. Two episodes …
Esclusioni etniche nei regolamenti cultuali greci: la norma di Paros (IG XII 5, 225)
2019
This study aims to examine a well-known inscription (IG XII.5, 225) dated to the mid-fifth century BC and found in Paroikia, near the acropolis of the ancient polis of Paros. It shows a typical formula of access limitation to local cults: according to most scholars, the cult in question is to be identified with the worship of Kore Astos (the Citizen), who is mentioned in the second line. The Dorians are excluded from this cult, as is shown by the expression (xenoi Dorie) appearing at the beginning of the text in a very relevant position. On the basis of a close comparison between this text and other epigraphs as well as literary documents containing proscriptions which prevent foreigners fr…