Search results for "Auditory Threshold"
showing 10 items of 33 documents
Transient evoked otoacoustic emissions in vestibular neuritis.
2007
Objectives: Partial or total degeneration of the vestibulocochlear anastomosis at its takeoff from the saccular ganglion and regenerating efferent neural buds under the cochlear outer hair cells (OHCs) have been found in the temporal bones of human patients with a history of vestibular neuritis (VN). We sought to test whether VN has any functional impact on the ipsilateral OHCs by means of transient evoked otoacoustic emission (TEOAE) testing. Methods: We retrospectively analyzed prospectively collected TEOAE data of 28 patients (19 female, 9 male; age range, 21 to 60 years; median age, 42.5 years). The pure tone air conduction hearing thresholds at each standard audiometric frequency (0.12…
DPOAE‐Grams in Patients with Acute Tonal Tinnitus
2005
To investigate cochlear outer hair cell function in patients with acute tonal tinnitus and normal or near-normal hearing threshold.Prospective controlled study in an academic tertiary health center. Distortion products of otoacoustic emissions (DPOAE)-grams of 32 ears with acute tonal tinnitus and normal hearing or minimal hearing loss were compared with those of 17 healthy nontinnitus ears.Tinnitus ears exhibited relatively increased amplitudes of DPOAE at high frequencies (4-6.3 kHz) when compared with the group of healthy ears and relatively decreased DPOAE amplitudes at middle frequencies (1650-2400 Hz). Statistically significant ( P0.01) increased mean values of DPOAE amplitudes were o…
Intratympanic Dexamethasone and Hyaluronic Acid in Patients with Low-Frequency and Ménière's-Associated Sudden Sensorineural Hearing Loss
2005
Steroids are widely used for the treatment of cochleovestibular disorders. Direct steroid application in the middle ear cavity, when combined with a round window membrane permeability-modulating substance, increases the level of the steroid reaching the target cells. We measured hearing in patients with idiopathic isolated low-frequency sensorineural hearing loss and in patients with sudden sensorineural hearing loss and a history of Ménière's disease. Contradictory reports about effectiveness of intratympanic steroid therapy on vertigo control and hearing improvement in patients with Ménière's disease exist in the literature.Eighteen patients with isolated low-frequency idiopathic sudden s…
Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipient…
2010
Abstract: The Nucleus CI24RE Freedom device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 μV. However, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C …
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…
Effects of contralateral white noise stimulation on transitory evoked otoacoustic emissions in patients with acoustic neuroma.
1995
Abstract Transitory evoked otoacoustic emissions are normal phenomena observed in most persons with hearing levels greater than 35 dB. Further, masking of the contralateral ear produces amplitude reductions in the transitory evoked otoacoustic emissions. We have undertaken a study of transitory evoked otoacoustic emissions in 20 patients with acoustic neuroma. All patients were assessed for transitory evoked otoacoustic emissions bilaterally, with and without contralateral masking with white band noise at 40, 50, and 60 dB. We found that transitory evoked otoacoustic emissions were present in 30% of ears with tumor and that the presence of transitory evoked otoacoustic emissions is associat…
Influence of nerve branch of origin and extracanalicular extension of the tumor on hearing after middle fossa removal of vestibular schwannoma
2007
Neither nerve branch of origin nor extracanalicular (up to 1 cm) extension of a vestibular schwannoma (VS) influence the postoperative hearing outcome in patients operated via a middle cranial fossa (MCF) approach.To test whether the nerve branch of tumor origin and an extracanalicular, up to 1 cm, tumor extension influences hearing outcome after MCF VS surgery.This was a retrospective case review of 50 patients with postoperative pure-tone audiogram (PTA) performed later than 90 days after surgery. Twenty patients had a superior vestibular nerve (SVN) tumor and 27 patients had an inferior vestibular nerve (IVN) tumor. In three patients the nerve branch of origin of the VS could not be uneq…
Genetic and environmental influences on hearing at different frequencies separately for the better and worse hearing ear in older women
2007
The purpose of the present study was to examine the relative contribution of genetic and environmental effects on the air-conducted hearing threshold levels at low (0.125-0.5 kHz), mid (1-2 kHz), and high (4-8 kHz) frequencies separately for the better and worse hearing ear in older women. We also examined the distribution of audiogram configurations. Data was analysed using quantitative genetic modelling. As part of the Finnish twin study on aging (FITSA), hearing was measured in 103 monozygotic and 114 dizygotic female twin pairs aged 63-76 years. Approximately every third subject had a flat type, and two-thirds a descending type of audiogram configuration. No significant difference was o…
Genetic and environmental influences on hearing in older women.
2007
Background. This study examined the relative contribution of genetic and environmental effects on the air-conducted hearing threshold level (0.5‐4 kHz) and speech recognition threshold level of the better ear as well as self-reported hearing in older women. Methods. Hearing was measured as a part of the Finnish Twin Study on Aging in 103 monozygotic (MZ) and 114 dizygotic (DZ) female twin pairs aged 63‐76 years. Audiometric measured hearing was tested using standardized methods in soundproof conditions. Self-reported hearing was assessed by a structured question. Quantitative genetic modeling was used for data analyses. Results. No significant differences in age, exposure to noise, hearing-…
Are smartphone applications (App) useful to improve hearing?
2020
Le App per smartphone possono essere utili per migliorare l’udito?L’obiettivo dello studio è quello valutare l’efficacia di un’App per smartphone creata con lo scopo di migliorare le performance uditive sia in soggetti normoudenti che in pazienti affetti da ipoacusia da lieve a severa. Si tratta di uno studio analitico multicentrico, eseguito tra giugno e dicembre 2017, che ha analizzato un campione di 68 pazienti di cui 55 ipoacusici e 13 normoudenti; a tutti i pazienti sono stati somministrati test audiologici specifici sia durante l’utilizzo della suddetta App che in assenza di ausili uditivi. Il protocollo di valutazione audiologica prevedeva l’esecuzione di un’audiometria tonale limina…