Accuracy and accommodation capability of a handheld autorefractor
2000
Purpose: To determine the accuracy of measurement by the Nikon Retinomax handheld autorefractor and its ability to relax accommodation. Setting: Pediatric Section, Department of Ophthalmology, University of Mainz, Germany. Methods: To perform a series of comparative measurements, autorefractor readings were obtained on healthy young adults (students) and on children aged 2 to 12 years. The autorefractor readings were compared with subjective refractions of the young adults and with cycloplegic retinoscopy of the children. Results: In adults, the accuracy of the handheld autorefractor measurements was comparable to that of conventional tabletop autorefractors. In children, the autorefractor …
Heritability of refractive astigmatism: a population-based twin study among 63- to 75-year-old female twins.
2013
PURPOSE: To examine the heritability of refractive astigmatism in older women. METHODS: Astigmatism was measured with an autorefractor in 88 monozygotic and 82 dizygotic female twin pairs aged 63 to 75 years. The prevalence and distribution of astigmatism and polar values J0 and J45 were estimated by standard statistical methods. Bivariate maximum likelihood model fitting was used to estimate genetic and environmental variance components using information from both eyes. RESULTS: Mean astigmatism of the more astigmatic eye was 0.93 diopters (D; SD ±0.58). Astigmatism of at least 0.25 D, 0.5 D, 0.75 D, or 1.0 D in either eye was present in 99.7%, 88.5%, 66.5%, and 46.2% of cases, respectivel…
Heritability of Spherical Equivalent
2010
Purpose To examine the heritability of spherical equivalent (SE) in older women. Design Population-based twin study. Participants Ninety monozygotic (MZ) and 86 dizygotic (DZ) female twin pairs aged 63 to 76 years who were born from 1924 through 1937. Methods Ocular refraction was measured using an autorefractor and controlled by the subjective method. The contributions of genetic and environmental factors to individual differences in SE were estimated by applying an independent pathway model to twin data. Main Outcome Measures Contribution of genetic and environmental effects to the variation in SE. Results Mean SE of the study population was 1.68 (standard deviation, ±1.82) with no differ…
Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.
2019
To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…
Relative Peripheral Myopia Induced by Fractal Contact Lenses
2018
[EN] Purpose: To assess the peripheral refraction induced by Fractal Contact Lenses (FCLs) in myopic eyes by means of a two-dimensional Relative Peripheral Refractive Error (RPRE) map. Materials and Methods: This study involved 26 myopic subjects ranging from -0.50 D to -7.00 D. FCLs prototypes were custom-manufactured and characterized. Corneal topographies were taken in order to assess correlations between corneal asphericity and lens decentration. Two-dimensional RPREs were measured with an open-field autorefractor at 67 points, covering the central 60 x 30 degrees of the visual field. The bidimensional RPRE vector components: M, J(0) and J(45) of the difference between the values obtain…
Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses
2021
Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…
A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects
2008
A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
2017
Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…