Search results for "BED"

showing 10 items of 1605 documents

CFD prediction of bubble behavior in two-dimensional gas-solid fluidized beds

2009

This work focuses on the computational fluid dynamics (CFD) simulation of a laboratory-scale, two-dimensional fluidized bed and the relevant experiments in order to validate the prediction capability of the adopted codes and models. Both experimental and computational quantitative data were analyzed by means of an original digital image analysis technique, allowing for coherent comparison of computational and experimental results. In particular, this work analyzes the capability of the CFD simulations in predicting the fluctuating behavior of bubbling fluidized beds by means of frequency analysis of bubble-related phenomena.

Materials sciencebusiness.industryBubbleGeneral EngineeringMechanicsComputational fluid dynamicsCondensed Matter PhysicsAnnealing (glass)Physics::Fluid DynamicsModeling and SimulationDigital image analysisTwo-dimensional gasdigital image analysisFluidizationbusinessBond fluctuation modelBubbling fluidized bedBubbling fluidized bedCFD SIMULATIONS
researchProduct

Heteroepitaxial growth of Co on W(110) investigated by scanning tunneling microscopy

2003

We investigated the growth of Co submonolayers on bcc W(110) by scanning tunneling microscopy. Due to the strong Co-W bonding, monolayers of Co grow in equilibrium pseudomorphically on W(110) until the monolayer is almost completed. When excess atoms are deposited atop the pseudomorphic monolayer, it transforms to a close-packed (cp) monolayer with misfit dislocation lines parallel to $[11\ifmmode\bar\else\textasciimacron\fi{}0]$ (Nishiyama-Wassermann orientation). The structure of the cp monolayer, as concluded from atomically resolved STM images, deviates from the rigid hard-sphere model of a cp (111) layer. Details of the structure are compared to a structure model previously proposed by…

Materials sciencebusiness.industrylaw.inventionCrystallographyOpticslawMonolayerDislocationStructured modelScanning tunneling microscopebusinessLayer (electronics)Embedded atom modelBar (unit)Physical Review B
researchProduct

SU-E-T-691: Shielding Evaluation of a Treatment Room with An Electronic Brachytherapy System

2015

Purpose: Esteya™ (Elekta) is a brachytherapy electronic system used for treating skin cancer lesions. This unit is based on a 69.5 kV X-ray source and a surface applicator which produces a circular beam of a specific diameter, which varies from 1 to 3 cm. This study aims to establish the radiation protection measures for the system. Methods: A characterization of the scattered and leakage radiation of the system was implemented by means of experimental measurements. The scattered radiation measurements were performed with a Berthold LB133 ionization chamber, evaluating the dose rate for different distances from the applicator surface. The patient was simulated through water equivalent solid…

Materials sciencebusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineIonizing radiationLead shieldingAbsorbed doseIonization chamberElectromagnetic shieldingmedicineDosimetryRadiation protectionbusinessNuclear medicineMedical Physics
researchProduct

SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

2016

Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose r…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineCollimated lightAbsorbed dosemedicineDosimetryRadiochromic filmNuclear medicinebusinessDose rateSkin lesionMedical Physics
researchProduct

Study and design of a controlled oscillator for an embedded system to measure the complex impedance of PEM fuel cell »

2017

We present in this paper the study and the design of a voltage controlled oscillator (VCO) for an embedded system to diagnose the PEM fuel cell. Some problems related to fuel cells used in the electric vehicle field are the management of its efficiency and the lifetime of its membranes. To do this, the diagnosis using measuring the complex impedance is an important phase. It is based on the injection of a perturbation signal at the output of the PEM fuel cell, then we observe its behavior by measuring its impedance. The used measurement method is the electrochemical impedance spectroscopy (EIS) using the load modulation technique, which is implemented in an embedded measurement system based…

Materials sciencebusiness.product_categorybusiness.industry[SPI] Engineering Sciences [physics]System of measurementAutomatic frequency controlProton exchange membrane fuel cell02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesDielectric spectroscopyMicrocontrollerVoltage-controlled oscillator[SPI]Engineering Sciences [physics]Embedded systemElectric vehicle0210 nano-technologybusinessElectrical impedanceComputingMilieux_MISCELLANEOUS
researchProduct

Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.

2011

Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…

Materials sciencegenetic structuresUltraviolet Raysmedicine.medical_treatmentIntraocular lensRadiationmedicine.disease_causelaw.inventionOpticsRadiation ProtectionlawLens CrystallinemedicineAnimalsHumansIrradiationLenses Intraocularbusiness.industryMediterranean RegionAlbedoeye diseasesLens (optics)OphthalmologyWavelengthmedicine.anatomical_structureSunlightHuman eyesense organsRabbitsbusinessUltravioletJournal francais d'ophtalmologie
researchProduct

Gamma-ray irradiation tests of CMOS sensors used in imaging techniques

2014

Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were car ried out by means of IGS-3 gamma irradiation facility of Palermo Uni ver sity, based on 60Co sources with dif fer ent ac tiv i ties. To re duce the dose rate and re al ize a nar row gamma-ray beam, a lead-collimation sys tem was pur posely …

Materials scienceimaging technique CMOS image sensor gamma irradiationPixelSettore ING-IND/20 - Misure E Strumentazione Nuclearibusiness.industryImage qualityRadiationimaging techniqueSettore ING-INF/01 - Elettronicagamma irradiationBackground noiseNuclear Energy and EngineeringCMOSCMOS image sensorAbsorbed doseOptoelectronicslcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityIrradiationImage sensorSafety Risk Reliability and QualitybusinessNuclear Technology and Radiation Protection
researchProduct

A New Technique of Invariant Statistical Embedding and Averaging in Terms of Pivots for Improvement of Statistical Decisions Under Parametric Uncerta…

2021

In this chapter, a new technique of invariant embedding of sample statistics in a decision criterion (performance index) and averaging this criterion via pivotal quantities (pivots) is proposed for intelligent constructing efficient (optimal, uniformly non-dominated, unbiased, improved) statistical decisions under parametric uncertainty. This technique represents a simple and computationally attractive statistical method based on the constructive use of the invariance principle in mathematical statistics. Unlike the Bayesian approach, the technique of invariant statistical embedding and averaging in terms of pivotal quantities (ISE&APQ) is independent of the choice of priors and represents …

Mathematical optimizationComputer scienceMathematical statisticsPrior probabilityBayesian probabilityEmbeddingDecision ruleInvariant (mathematics)ConstructiveParametric statistics
researchProduct

Adaptive memory programming for constrained global optimization

2010

The problem of finding a global optimum of a constrained multimodal function has been the subject of intensive study in recent years. Several effective global optimization algorithms for constrained problems have been developed; among them, the multi-start procedures discussed in Ugray et al. [1] are the most effective. We present some new multi-start methods based on the framework of adaptive memory programming (AMP), which involve memory structures that are superimposed on a local optimizer. Computational comparisons involving widely used gradient-based local solvers, such as Conopt and OQNLP, are performed on a testbed of 41 problems that have been used to calibrate the performance of su…

Mathematical optimizationGlobal optimumGeneral Computer ScienceMultimodal functionAdaptive methodModeling and SimulationTestbedConstrained optimizationManagement Science and Operations ResearchGlobal optimizationTabu searchAdaptive memory programmingMathematicsComputers & Operations Research
researchProduct

On multi-objective optimal reconfiguration of MV networks in presence of different grounding

2015

The present work faces the traditional multi-objective optimal reconfiguration problem of a distribution grid including the safety issue in the objective functions. Actually, in many medium voltage networks still transformers with ungrounded neutral and with resonant grounded neutral coexist in the same area. This may be sometimes cause of problems during a single-line-to-ground fault if the ground electrodes of one or more cabins, initially designed for satisfying the safety conditions in a resonant grounded neutral network, after the reconfiguration are in a grounded neutral one or vice versa. In the paper a safety objective function is defined and the Non dominated Sorting Genetic Algori…

Mathematical optimizationOptimization problemGeneral Computer ScienceComputer science020209 energyDistribution gridGlobal grounding02 engineering and technologyFuzzy logiclaw.inventionMetallawMV network0202 electrical engineering electronic engineering information engineeringTransformerReconfiguration;MV network;Global grounding;Distribution grid;Genetic algorithmGroundbusiness.industryComputer Science (all)Control reconfigurationEarthing systemSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaGenetic algorithmvisual_artEmbedded systemElectrodeReconfigurationvisual_art.visual_art_mediumEvolution strategybusiness
researchProduct