Search results for "BREATH"
showing 10 items of 528 documents
Contrast-enhanced MRI of the lung
2000
The lung has long been neglected by MR imaging. This is due to unique intrinsic difficulties: (1) signal loss due to cardiac pulsation and respiration; (2) susceptibility artifacts caused by multiple air-tissue interfaces; (3) low proton density. There are many MR strategies to overcome these problems. They consist of breath-hold imaging, respiratory and cardiac gating procedures, use of short repetition and echo times, increase of the relaxivity of existing spins by administration of intravenous contrast agents, and enrichment of spin density by hyperpolarized noble gases or oxygen. Improvements in scanner performance and frequent use of contrast media have increased the interest in MR ima…
Functional MRI of the lung using hyperpolarized 3-helium gas
2004
Lung imaging has traditionally relied on x-ray methods, since proton MRI is limited to some extent by low proton density in the lung parenchyma and static field inhomogeneities in the chest. The relatively recent introduction of MRI of hyperpolarized noble gases has led to a rapidly evolving field of pulmonary MRI, revealing functional information of the lungs, which were hitherto unattainable. This review article briefly describes the physical background of the technology, and subsequently focuses on its clinical applications. Four different techniques that have been used in various human investigations are discussed: ventilation distribution, ventilation dynamics, and small airway evaluat…
Silicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
2016
Two of the biggest challenges in medicine today are the need to detect diseases in a noninvasive manner and to differentiate between patients using a single diagnostic tool. The current study targets these two challenges by developing a molecularly modified silicon nanowire field effect transistor (SiNW FET) and showing its use in the detection and classification of many disease breathprints (lung cancer, gastric cancer, asthma, and chronic obstructive pulmonary disease). The fabricated SiNW FETs are characterized and optimized based on a training set that correlate their sensitivity and selectivity toward volatile organic compounds (VOCs) linked with the various disease breathprints. The b…
Hyperpolarized 3helium gas as a novel contrast agent for functional MRI of ventilation.
2002
The use of inhaled hyperpolarized 3He gas in MRI is a recent approach for ventilation imaging. It has recently received enormous interest since it is capable of producing new and regional information on normal and abnormal lung ventilation. Promising preclinical and preliminary clinical results are the driving force to start phase II trials with patients suffering from obstructive and restrictive lung diseases.
Dynamic19F-MRI of pulmonary ventilation using sulfur hexafluoride (SF6) gas
2001
A new method for dynamic imaging of pulmonary wash-in and wash-out kinetics of inhaled sulfur hexafluoride (SF6) gas was developed. Measurements at the fluorine-19 Larmor frequency were performed in pigs using a gradient echo pulse sequence with 0.5 ms echo time and a measurement time of 9.1 s per image. Dynamic MRI was performed during wash-in and wash-out of SF6 gas in mechanically ventilated porcine lungs. A postprocessing strategy was developed for quantitative determination of wash-out time constants in the presence of noise. Mean wash-out constants were 4.78 ± 0.48 breaths vs. 4.33 ± 0.76 breaths for left and right lung when ventilation was performed with low tidal volume, and 1.73 ± …
3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes
2000
MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…
Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*
2000
Objective Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. Material and methods Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). Re…
Computertomographie der Atelektase
1987
After breathing pure oxygen, total atelectasis of one lung was produced in ten dogs; its development and regression was followed by CT and by conventional radiology. 30 seconds after cessation of ventilation, it was possible to show a rise in CT density of the atelectatic lung from -764 +/- 32 HU to -739 +/- 49 HU. The average time from the cessation of ventilation to total atelectasis averaged 5.5 +/- 1.1 minutes. The earliest sign on conventional radiographs was often seen after 30 seconds and usually after 60 seconds and consisted of mediastinal displacement. Extensive atelectasis regressed in only one out of six animals within one hour after resuming ventilation. The experimental method…
Elucidation of structure-function relationships in the lung: contributions from hyperpolarized 3 helium MRI
2002
Magnetic resonance imaging (MRI) using hyperpolarized 3helium (He) gas as the source of signal provides new physiological insights into the structure-function relationships of the lung. Traditionally, lung morphology has been visualized by chest radiography and computed tomography, whereas lung function was assessed by using nuclear medicine. As all these techniques rely on ionizing radiation, MRI has some inherent advantages. 3He MRI is based on 'optical pumping' of the 3He gas which increases the nuclear spin polarization by four to five orders of magnitude translating into a massive gain in signal. Hyperpolarized 3He gas is administered as an inhaled 'contrast agent' and allows for selec…
Helium-3-MRT der Lungenventilation: Erste klinische Anwendungen
1997
PURPOSE: of the study is the visualisation of normal pulmonary ventilation in healthy volunteers and the evaluation of abnormalities in patients with different lung diseases using 3He magnetic resonance imaging (3He-MRI). MATERIAL AND METHODS: Hyperpolarized 3He gas (V = 300 ml, p = 3 x 10(5) Pa, polarised to 35-45% by optical pumping, provided in special glass cells) was inhaled by eight healthy volunteers and ten patients with different lung diseases. A 3D FLASH sequence (TR = 11.8 ms; TE = 5 ms; matrix 144 x 256, FOV 350 mm, section thickness 7-10 mm, coronal orientation) was performed in a single breath-hold (22-42 s). Clinical and radiological examinations were available for correlatio…