Search results for "Beni culturali"
showing 10 items of 1017 documents
Time-resolved X-ray scattering as a tool to probe heme proteins structural dynamics in solution
2013
Time-resolved wide-angle X-ray scattering (TR-WAXS) is a recently developed technique allowing to probe global structural changes of proteins in solution. We have used TR-WAXS to investigate large conformational changes of heme proteins (wild-type and mutant hemoglobin, neuroglobin, etc.) that cannot take place when these macromolecules are in a crystalline environment. Our data revealed detailed information on kinetic and thermodynamic properties of the investigated proteins and demonstrate the potentiality of the TR-WAXS technique.
The effect of water on protein dynamics
2004
Neutron diffraction and spectroscopy were applied to describe the hydration and dynamics of a soluble protein and a natural membrane from extreme halophilic Archaea. The quantitative dependence of protein motions on water activity was clearly illustrated, and it was established that a minimum hydration shell is required for the systems to access their functional resilience, i.e. a dynamics state that allows biological activity.
Planning a new international comparison on EPR dosimetry with tooth enamel: a EURADOS WG10 proposal
2018
ntroduction L-a-alanine has aroused considerable interest for use in radiation ESR dosimetry. In this work, we examined the energy response of alanine ESR films in the low energy X-photon energy range between 1 keV and 40 keV. Dose measurements through a reference ionization chamber and a semiconductor detection system were also performed to complement ESR measurements. Methods Commercial alanine ESR films were used. All ESR signal measurements were also done using an XBand (9.7 GHz) Bruker spectrometer. The dosimeters were irradiated at the "Livio Scarsi" Laboratory (LAX) of the University of Palermo, where X-ray beams in the 1–40 keV energy range are produced using a Seifert SN60 tube. Re…
Monte Carlo simulation of the energy released by neutrons on organic compounds for EPR dosimetry
2022
In this work we report the analyses of the energy released per unit mass in organic compounds used for EPR dosimetry exposed to neutron beams in order to predict the increase in dose achievable by addition of gadolinium (Gd) inside the pellets. In particular, Monte Carlo (MC) simulations were carried out for alanine, ammonium tartrate and phenolic compounds irradiated with neutron beams with different energy spectra at various depths inside a water phantom. The addition of gadolinium increases sensitivity of these dosimeters to neutrons thanks to the high gadolinium cross section for neutron capture and to the large number of secondary particles (mainly Auger and internal conversion electro…
EXPOSURE OF Gd2O3-ALANINE AND Gd2O3-AMMONIUM TARTRATE ESR DOSIMETERS TO THERMAL NEUTRONS: EXPERIMENTS AND MONTE CARLO SIMULATIONS
2008
Characterization of phenolic solid state pellets for ESR dosimetry with radio-therapeutic photon and electron beams
2018
Introduction Among the various dosimetric techniques used for characterizing the radiation beams used in radiation therapy, the electron spin resonance (ESR) arouses increasing interest for applications in various therapy procedures. In this work we report the ESR investigation of particular phenol compound (IRGANOX 1076) exposed to clinical photon and electron beams (Gallo et al., 2017). Methods Phenol (IRGANOX 1076 - Sigma Aldrich) pellets were produced also with paraffin (10% by weight). Phenol pellets were exposed to clinical photon and electron beams at various energies produced by a linear accelerator (LINAC) Siemens Primus (Siemens Medical Systems, CA, USA) installed at the Radiother…
Watch glasses exposed to 6 MV photons and 10 MeV electrons analysed by means of ESR technique
2011
ESR study of proton irradiation response of watch glasses.
2009
Dosimetria ESR con alanina per adronterapia per protoni e ioni carbonio
2014
Electron Spin Resonance (ESR) dosimetry for clinical radiation beams.
2016
In the last two decades the electron spin resonance (ESR) technique has been widely adopted for dosimetry of the radiation beams used in radiation therapy. In particular, alanine dosimtery is nowadays recognized as an international standard system for transfer dosimetry and for high doses. This is because among the various solid-state dosimeters the alanine ESR detectors present several advantages such as: tissue equivalence, linearity of its dose-response over a wide range, high stability of radiation induced free radicals, no destructive read-out procedure, no sample treatment before EPR signal measurement. In this presentation the main applications of ESR dosimetry for the characterizati…