Search results for "Biocompatible Material"
showing 10 items of 290 documents
New generation super alloy candidates for medical applications: Corrosion behavior, cation release and biological evaluation
2014
Three super alloy candidates (X1 CrNiMoMnW 24-22-6-3-2 N, NiCr21 MoNbFe 8-3-5 AlTi, CoNiCr 35-20 Mo 10 BTi) for a prolonged contact with skin are evaluated in comparison with two reference austenitic stainless steels 316L and 904L. Several electrochemical parameters were measured and determined (E(oc), E(corr), i(corr), b(a), b(c), E(b), R(p), E(crev) and coulometric analysis) in order to compare the corrosion behavior. The cation release evaluation and in vitro biological characterization also were performed. In terms of corrosion, the results reveal that the 904L steels presented the best behavior followed by the super austenitic steel X1 CrNiMoMnW 24-22-6-3-2 N. For the other two super a…
Modification of human platelet adhesion on biomaterial surfaces by protein preadsorption under static and flow conditions.
2004
Biomaterial-induced thrombosis remains one of the main complications of vascular implant devices. Preadsorbed proteins on the biomaterial/blood interface will modify the adhesion and activation of platelets (PTLs) during the initial contact-phase. Our results clearly show that PTL-adherence on biomaterials is influenced not only by protein preadsorption, but also by flow conditions. The covalent coating of TCPS and glass by phosphorylcholine (PC) induces a significant decrease of PTL adhesion but leads to a slight, but nevertheless significant activation of PTL, which was detected by the induction of P-selectin expression using FACS analysis. Methodologically, the visualization of PTL adhes…
Biocompatible micelles based on squalene portions linked to pegylated polyaspartamide as potential colloidal drug carriers
2011
The effect of electrochemically simulated titanium cathodic corrosion products on ROS production and metabolic activity of osteoblasts and monocytes/…
2006
Nowadays aseptic loosening is the most common cause of orthopaedic implant failure. Some of its reasons have already been described up to now; however, others remain still hypothetical. Besides the inflammatory response to wear particles originating at different sources, the role of reactive oxygen species as products of cellular reactions and/or as a result of the process of corrosion of an implant leading to implant failure has recently been discussed too. In the present study, we used a galvanostatic polarization to simulate the cathodic partial reaction of the corrosion process at a titanium alloy surface. With respect to cells occurring at the interface of a metal implant, the behaviou…
Preparation of three-layered porous PLA/PEG scaffold: relationship between morphology, mechanical behavior and cell permeability.
2015
Interface tissue engineering (ITE) is used to repair or regenerate interface living tissue such as for instance bone and cartilage. This kind of tissues present natural different properties from a biological and mechanical point of view. With the aim to imitating the natural gradient occurring in the bone-cartilage tissue, several technologies and methods have been proposed over recent years in order to develop polymeric functionally graded scaffolds (FGS). In this study three-layered scaffolds with a pore size gradient were developed by melt mixing polylactic acid (PLA) and two water-soluble porogen agents: sodium chloride (NaCl) and polyethylene glycol (PEG). Pore dimensions were controll…
Perylenetetracarboxylic anhydride as a precursor of fluorescent carbon nanoonion rings
2015
[EN] Thermal annealing at 400 degrees C of perylenetetracarboxylic anhydride in low molecular mass PEG gives rise to the formation of well defined nanoobjects of 2.5 nm height and size distribution from 10 to 65 nm (average 40 nm) after purification of the raw mixture with silicagel chromatography. TEM reveals that the flat nanoobjects are constituted of concentric graphenic rings (0.34 nm interlayer distance). The morphology of the nanoparticles resembles onion rings of nanometric dimensions (nanoonion rings C-NOR). C-NOR particles have an excitation dependent emission with lambda(em) from 430 to 570 nm and a maximum emission quantum yield of 0.49. C-NOR particles can be internalized into …
Cytotoxicity of Root Canal Filling Materials to Three Different Human Cell Lines
2001
The aim of this study was to investigate the biological compatibility of five root canal sealers (Sealapex, Endion, Super-EBA, Ketac-Endo, and AH Plus) and regular and calcium hydroxide-based gutta-percha in three different human cell lines. Cultures without root canal sealers were used as controls. Cell growth, cell morphology, cell viability, protein content of the cells, and prostaglandin E 2 (PGE 2 ) release were used as parameters to determine the cytotoxicity of the materials. The protein content of the three cell lines—nasal fibroblasts, gingival fibroblasts, and epithelial tumor cells—was significantly reduced (p ≤ 0.001) by all materials tested. Determinations of PGE 2 release show…
Preparation, characterization and in vitro antimicrobial activity of ampicillin-loaded polyethylcyanoacrylate nanoparticles.
1998
In this paper, the experimental conditions for preparing ampicillin-loaded polyethylcyanoacrylate (PECA) nanoparticles are described. The effects of drug concentration and surfactant type in the polymerization medium on the particle size distribution and loading capacity were studied. The results of these studies show that only the type of surfactant has an impact on the nanoparticle dimensions. The release rate of ampicillin from PECA nanoparticles at pH 7.4 (extracellular value pH) performed either with and without esterases, show that the drug release is considerably increased in the presence of these exzymes. The results of drug release study at pH 1.1 (simulated gastric juice) are very…
Bioinspired Fabrication of Bio-Silica-Based Bone-Substitution Materials
2010
The gold standard for bone reconstruction is the use of autogeneic grafts from various donor regions, since they possess osteoinductive as well as osteoconductive potential. Only a few synthetic materials possess/display properties that allow optimal bone reconstitution. Previously, we showed that the natural product, bio-silica, comprises osteoinductive, and probably also osteoconductive activity. Bio-silica is formed enzymatically via silicatein; this enzyme has been isolated from siliceous sponges and has also been cloned and prepared recombinantly. In the present study, silicatein was encapsulated together with its substrate, sodium metasilicate, in poly(D,L-lactide)/poly(vinyl pyrrolid…
Survival and differentiation of embryonic neural explants on different biomaterials
2006
Biomaterials prepared from polyacrylamide, ethyl acrylate (EA), and hydroxyethyl acrylate (HEA) in various blend ratios, methyl acrylate and chitosan, were tested in vitro as culture substrates and compared for their ability to be colonized by the cells migrating from embryonic brain explants. Neural explants were isolated from proliferative areas of the medial ganglionic eminence and the cortical ventricular zone of embryonic rat brains and cultured in vitro on the different biomaterials. Chitosan, poly(methyl acrylate), and the 50% wt copolymer of EA and HEA were the most suitable substrates to promote cell attachment and differentiation of the neural cells among those tested. Immunofluor…